Safer-III-TJ Ultra Pure Water Machine
productcharacteristicFeather:
Double membrane double pumpThe system realizes complete dual stage reverse osmosis, system circulation, and full stage filter alarm prompt functions, and the lifespan of consumablesManagementAutomatic detection and alarm functions such as system water shortage alarm, water tank full alarm, water quality exceeding alarm, etc.
use double membrane and double pump system, adopted to realize complete double-stage reverse osmosis, system circulation and alarm function of full-stage filter element. automatic detection and alarm functions such as water shortage alarm, full water tank alarm and water quality exceeding standard alarm.
Ultra pure water system with built-in circulation settings for optimal preparationUPWater quality requirements. The circulatory system can be freely started and shut down to maintain a low bacterial contamination state.
The ultra-pure water system has built-in cycle setting to prepare the best required UP water quality requirements. The circulatory system can be turned on and off freely to keep the bacterial contamination low.
5.0Inch LCD display screen, full animation menu display, integrated three-way water quality online monitoring, real-time online monitoring of incoming waterROandUPThree water quality sensors andfourAccess of road switch signals.
5.0-inch LCD display screen, full animation menu display, integrated with three channels of water quality online monitoring, real-time online monitoring of water inlet, RO and UP three channels of water quality sensor and four-channel switch signal access.
Timing and quality control(1-18.25MΩ.cm)Take water.
Timing, qualitative (1-18.25 MΩ. Cm) water.
equipUSB HostInterface, supporting data export function for historical alarm records and historical water intake records.
with USB Host interface to support the data export function of historical alarm record and historical water intake record.
Four digitnumberUser password protection function. Equipped with timed standby and automatic shutdown function. Timed standby(0~60min)Scheduled shutdown(0~24h).
Four-digit user password protection function. It has the function of automatic shutdown when standby. Timed standby (0~60min), timed shutdown (0~24h).
Adopting Dow from the United StatesDOWimported with original packagingROdiaphragm.fully automaticROMembrane anti scaling flushingProgram,Manual and automatic flushing functions, extendROMembrane lifespan, maintaining a low bacterial contamination state.
Imported RO diaphragm with original packaging from DOW. Automatic RO film anti-scale washing procedure, manual and automatic washing function, prolong the service life of RO film and keep low bacterial contamination.
Water quality detection sensor resistance pool constant:0.01-1Temperature sensitivity ±0.1℃, with25℃ automatic temperature compensation function
Water quality detection sensor resistance pool constant: 0.01-1, temperature sensitivity±0.1℃, with 25℃automatic temperature compensation function
Equipped with analog pressure sensors and analog liquid level sensors, it can directly display the inlet pressure and water tank storage capacity.
Equipped with simulated pressure sensor and simulated liquid level sensor, it can directly show the inlet pressure and the amount of water stored in the tank.
Optional conical bottom design polyethylene ultrapure water storage tank with air filter for effective adsorptionCO2,Organic matter filters bacteria and particulate matter.
Optional polyethylene ultra-pure water storage tank with tapered bottom design, which contains air filter, can effectively absorb CO2, filter bacteria and particulate matter by organic matter.
All connectors have been obtainedNSFCertification, minimizing the system'sTOCseparate out.
The joints are all NSF certified to minimize TOC precipitation in the system.
Matte surface clamp typestrengthenPreprocessing components,maintenanceMore convenient.
Grinding surface clip-on pre - treatment component for more convenient maintenance.
New integrated ultra purification components ensure water production reaches18.2MΩ.cmReduceTOCseparate out
Integration of new super purified components, to ensure that the water production of 18.2 MΩ. Cm, reduce the TOC exhalation
Importlong life254&185nmdual wavelengthUVUV lamp, combined with medical grade316LOverflow hood, effective sterilization, reducingTOC,ImportUFUltrafiltration component,molecular cut off: MWCO5000DEffectively remove heat sources/Endotoxins,sartorius0.2 μ m terminal filterEnsure sterile effluent from the terminal Can be used for precise cell culture.
Imported ultra-long life 254-185nm dual wavelength UV UV lamp, combined with medical grade 316L flow mask, effective sterilization, reduce TOC, imported UF ultra filtration kit, trap molecular weight: MWCO5000D, effective removal of pyrogen/endotoxin, Sartorius 0.2m terminal filter to ensure terminal water sterile can be used for precision cell culture.
equipRS232Communication interface, optional micro printer or monitoring software.
Equipped with RS232 communication interface, can be selected with micro printer or monitoring software.
Adopting low voltage24VDCMain power supply,Water and electricity separation layout,Compliant with safety regulations,high strengthEngineering plastic chassis,Eliminate corrosion and rust.
adopt low-voltage 24VDC as the main power supply, and the layout of water and electricity separation, which conforms to the safety specifications. The high-strength engineering plastic case can prevent corrosion and rust.
Ultra low radiation. Adopting advanced electromagnetic compatibility design, it has strong anti-interference ability and low noise.
Ultra-low radiation. Using advanced electromagnetic compatibility design, with strong anti-interference ability, low noise and other characteristics
Technical ParameterSpecification
Product Name: Product |
basic type Standard |
Heat source removal type Eliminating endotoxin |
Ultra low organic matter type Low toc |
Super combination type Built-in TOC module |
PRODUCT MODEL model |
safer-III-TJ |
safer-III-TF |
safer-III-TV |
safer-III-TFV |
working conditions Working condition |
Source water: Urban municipal tap watersource water city municipal tap water (TDS≥300Enhanced pre-processing units are added to the system; (When TDS≥300, add and strengthen the pre treatment unit) temperaturetemperature:1-40℃; Source water pressuresource of water pressure:1-5kg/cm2; power supplypower:220V50HZ; powervoltage:30-80W |
|||
Working capacity for water production at 25 ℃ |
5L/h、10L/h、15L/h、20L/hSingle stage reverse osmosis+DI Single stage reverse osmosis+DI:30L/h、40L/h |
|||
Water Quality Standards for Produced Water Water quality |
The water quality meets the water specifications of the National Analytical Laboratory of China(GB6682-2008)Grade III and I standards, American ASTM, NCCLS, CAP standards; Absorbance (254nm, 1cm)≤0.001; Water quality analysis laboratory with China[$]s national water specifications (GB6682-2008)Ⅲ,Ⅰgrade standards, American ASTM, NCCLS, CAP standards; Absorbance (254nm,1cm)≤0.001; |
|||
Pure water quality RO Water Quality |
conductivity≤1μS/ cm@25℃;Electronic retention rate:96-99%Organic interception rate:>99%, dual stage reverse osmosisresistivity≤5μS/ cm@25℃,The water quality is better than the third level water standard of China National Laboratory Water (GB6682-2008). Conductivity≤1μS/ cm@25℃; Electronic interception rate: 96-99%, organic interception rate: > 99%, dual-stage reverse osmosis resistivity≤5 S/cm @ 25℃, the water quality is better than the Chinese national laboratory water (gb6682-2008) level 3 water standard. |
|||
Ultra pure water quality Ultra pure water quality |
Conductivity ≤ 0.055 μ S/ cm@25 ℃; Electrical resistivity ≥ 18.25M Ω? cm@25 ℃, with water quality better than the first-class water standard of China National Laboratory Water (GB6682-2008) Conductivity≤ 0.055 S/cm @ 25℃; Resistivity acuity 18.25 MΩ, cm @ 25℃, water quality is better than that of China[$]s national laboratory (GB6682-2008) with water level water standard |
|||
Water intake flow rate Out put Water flow rate |
1.5-2.0L/min |
|||
Heat source eliminating endotoxin
|
/ |
﹤0.001Eu/ml |
﹤0.02Eu/ml |
﹤0.001Eu/ml |
TOC |
﹤10ppb |
﹤5ppb |
﹤3ppb |
﹤3ppb |
RNA enzyme |
/ |
/ |
/ |
﹤0.01Eu/ml |
dnase |
/ |
/ |
/ |
﹤4pg/ml |
Microorganisms |
﹤0.01cfu/ml |
|||
Microparticle |
(Greater than 0.2 μ m)contentContent<1/ml |
|||
application area application |
Suitable for standard level experiments, high-purity standard solution preparation, quantitative analysis, blood testing, toxicity testing, buffer solution preparation, atomic absorption/emission spectroscopy, liquid chromatography, gas chromatography, etc used for standard class experiment, high purity standard solution preparation, quantitative analysia, blood test, toxicity test, butter solution preparation, atomatic absorption/emission spectrum,liquid chromatography etc. |
Applicable to molecular biology and life science, animal cell and plant cell culture, tissue culture, electrophoresis gel analysis, bioengineering, culture medium equipment, etc for molecular biology, animal cell and plant cell culture, electrophoresis gel analysia, bioengineering, medium equipment,etc. |
Suitable for trace analysis, high-performance liquid chromatography, ion chromatography, gas chromatography-mass spectrometry, total organic carbon (TOC) analysis, organic matter analysis, capillary electrophoresis, microelectronic component cleaning, toxicology research, environmental experimental analysis, etc
for trace analysia , high performance liquid chromatography, temperature connection, total organic carbon(TOC) analysia, organic |
Suitable for environmental analysis experiments, physics, electrochemistry, and interface research, various high-precision instrument analyses, molecular biology and life sciences, in vitro fertilization, tissue culture, animal and plant cell culture, two-dimensional electrophoresis experiments, protein purification, amino acid analysis, and gene research for environment analysia experiments, physics electrochemistry and interface research, various high precision instrument analysis, molecular biology and life science, tube baby,tissue culture, animal and plant cell culture, etc |
External dimensions Overall dimensions |
Length * Width * Height: 550 * 430 * 540mm Length * width * height |
III: showThree channel online monitoring of water quality:Water ingressROandUPThree way water quality
III: represents online monitoring of water quality of three channels: inlet water, RO and UP