ACI High PerformanceSeries frequency converters can be divided into three categories: universal G11, energy-saving P11, and vector V11

Product Technical Specifications:
project |
standard specification |
|
input |
rated voltage/frequency |
single phase220VThree phase220VThree phase380V;50Hz/60Hz |
Variable allowable value |
Voltage:-20%~ +20%Voltage imbalance rate:<3%Frequency: ±10% |
|
output |
rated voltage |
0~220V/380V/ |
Frequency range |
0Hz~500Hz |
|
Frequency Resolution |
0.01Hz |
|
Overload capacity |
P:120%IN, G:150% IN QF、Z、L: 180% IN 1minute |
|
|
Main control functions |
Modulation Type |
Optimize spatial voltage vectorSVPWMmodulate |
control mode |
svpwmSVPWMControl (with optimal low-frequency dead zone compensation characteristics) |
|
frequency accuracy |
Numerical setting: maximum frequency x ±0. 01%Simulation setting: maximum frequency x ±0.2% |
|
frequency resolution |
Number setting:0.01HzSimulation setting: maximum frequency x0.1% |
|
startfrequency |
0.40Hz~20.00Hz |
|
Torque boost |
Automatic torque increase, manual torque increase0.1%~30% |
|
V/FFFFFcurve |
fiveMethod: Constant torqueV/FCurve1User defined multiple segmentsV/FCurve method and3Type of torque reduction characteristic curve(2.0The power1.7Power sum1.2pow) |
|
Acceleration and deceleration curve |
Two ways: linear acceleration and decelerationSCurve acceleration and deceleration; Seven types of acceleration and deceleration times, time units(divide/second)Optional, longest6000minute |
|
dc braking |
DC braking start frequency:0~15.00Hz Braking time:0~60.0second Braking current:0~80% |
|
dynamic braking |
Built in energy consumption braking unit, can be connected with external braking resistor |
|
jog |
Jogging frequency range:0.1Hz~50.00Hz,Jogging acceleration and deceleration time0.1~60.0second |
|
built-inPI |
Can easily form a closed-loop control system |
|
Multi speed operation |
Through built-inPLCOr control the terminal to achieve multi-stage speed operation |
|
Textile swing frequency |
Can achieve preset frequency and adjustable center frequency swing function |
|
automatic voltage regulation(AVR) |
Maintain a constant output voltage when the grid voltage changes |
|
Automatic energy-saving operation |
Automatically optimize based on load conditionsV/FCurve, achieving energy-saving operation |
|
Automatic current limiting |
Automatically limit the current during operation to prevent frequent overcurrent faults and tripping |
|
Fixed length control |
After reaching the set length, the frequency converter shuts down |
|
communication |
haveRS485Standard communication interface, supportingASCIIandRTUTwo formatsMODBUSCommunication protocol. Equipped with master-slave multi machine linkage function |
|
project |
standard specification |
|
Operation function |
Run Command Channel |
Given the operation panel; Control terminal given; Serial port given; Can switch in three ways |
Frequency setting channel |
Keyboard analog potentiometer setting; keyboard▲、▼Key given; Function code number given; Serial port given; terminalUP/DOWNGiven;Simulated voltage setting; Simulated current setting; Pulse given; Combination given; Can switch between multiple given methods at any time |
|
Switch input channel |
Forward and reverse instructions;8Road programmable switch input, can be set separately35Various functions. |
|
Analog input channel |
2Analog signal input,4~20mA、0~10Voptional |
|
analog output channel |
Analog signal output, 4~20mAperhaps0~10VOptional, capable of outputting physical quantities such as set frequency and output frequency |
|
Switch, pulse output on/off road |
1Programmable open collector output;1Circuit relay output signal;1road0~20KHzPulse output signal, realizing various physical quantity outputs |
|
|
operate panel |
LEDDigital display |
Can display parameters such as set frequency, output voltage, output current, etc |
External instrument display |
Display of physical quantities such as output frequency, output current, and output voltage |
|
key lock |
Realize full locking of all buttons |
|
Parameter copying |
The remote control keyboard can be used to achieve the function code parameter copying function between frequency converters. |
|
Protection function |
Overcurrent protection; Overvoltage protection; Undervoltage protection; Overheating protection; Overload protection, etc |
|
Any optional item |
Braking components; Remote control panel; Remote cable; Keyboard mounting bracket, etc |
|
environment |
Place of use |
Indoor, not exposed to direct sunlight, free from dust, corrosive gases, oil mist, water vapor, etc |
Sea wave height |
below1000Meter (higher than)1000Rice time needs to be reduced for use) |
|
ambient temperature |
-10℃~+40℃ |
|
humidity |
less than90%RHNo condensation |
|
vibrate |
less than5.9rice/second2(0.6G) |
|
storage temperature |
-20℃~+60℃ |
|
structure |
protection grade |
IP20(When selecting the status display unit or keyboard) |
Cooling method |
Forced air cooling |
|
Installation method |
Wall mounted, cabinet mounted |
|
Panel operation diagram:

External dimensions:


Company switchboard:
Company Fax: