Introduction to Zeiss Metallographic Microscope Axiovert 200 MAT
The Zeiss Axiovert 200 MAT is a versatile and high-performance tool widely used in material microscopy technology. From microstructure analysis to particle measurement, Axiovert 200 MAT can provide you with the highest performance and maximum flexibility in material development, quality control, and fault analysis. The Axiovert 200 MAT is a microscope specifically developed for the materials market, combining many of your long-standing advantages: high-performance optical system, easy operation, innovative technology, comprehensive functionality, and extremely high stability, meeting current and future application requirements.
Whether you choose manual or automatic mirrors, they both have these advantages. In summary, the Axiovert 200 MAT is the best character on the material microscope stage. This inverted material microscope combines strength and intelligence, making it an indispensable member of your team.
Characteristics of Zeiss metallographic microscope Axiovert 200 MAT
The Axiovert 200 MAT has extremely high technological content and unparalleled functionality due to its cutting-edge concept and high efficiency characteristics.
Excellent optical system suitable for materials research field
The design of the entire optical system fully considers factors such as light transmittance, illumination uniformity, and color difference correction, meeting the needs of the materials research field. The improvement in quality and performance ensures accurate images and realistic colors. Also, the use of "light trap" technology eliminates the interference of stray light.
EC Epiplan-Noflur objective lens, with the best color and contrast
High contrast and high-quality images are provided by the EC Epiplan-Noflur objective lens. It is based on the IC2S optical system and contributes the finest quality. For example, this type of objective lens has a long working distance and high numerical aperture, is easy to operate, and has high resolution. This type of objective lens has rich contrast, capturing clear and sharp images, which is very advantageous for post image processing and analysis. It laid the foundation for the use of high-resolution digital cameras.
TIC: Advanced measurement technology
A new standard for measurement technology - due to the use of circular polarization technology, it is easy to measure the optical path difference, and you can observe the interference effect in all directions of the sample clearly (as shown in the figure). The measurement range of optical path difference is between 5 micrometers and 20 nanometers. TIC (Total Interference Contrast) is an innovative technology that utilizes sharp contrast feedback
C-DIC: Innovative high contrast technology
This is an innovation that you see as you believe. Compared to traditional DIC, the Axiovert 200 MAT offers a novel C-DIC technology that operates under circular polarization. DIC under circular polarization is the development direction of material microscopy, which solves the most common imaging problems. After using the C-DIC technology, the tissue structure of the sample, which was usually only visible in one direction, can now be seen as a whole. Regardless of the direction, there is no need to rotate the sample stage. You only need to adjust the knob on the DIC slide to observe all the tissue structures of the sample comprehensively and with high contrast. You will greatly appreciate this technology, as it means that the sample's information is both accurate and efficient, improving your work efficiency.
LCD display screen
All parameters are clear at a glance: The LCD display of Axiovert 200 MAT displays all important microscope settings parameters, such as:
Magnification factor
Objective state
light intensity
Overall magnification factor
In addition, the Axiovert 200 MAT allows you to conveniently measure thickness, which you will greatly appreciate. Both types of mirrors can use LCD display screens, making it easy to program with menus without the need for a computer. Another prominent feature is that for large samples, simply move the LCD display screen to a convenient and visible position without obstructing the viewing process
Optical path manager, intelligent management of light intensity
In the past, the light intensity had to be manually adjusted to suit every switching of the objective lens or observation method. Therefore, this process cannot be automated. The patented technology product of Axiovert 200 MAT, the optical path manager, provides a solution. Can Axiovert 200 M MAT microscope preserve the most? 0 lighting combination parameters (6 objective lenses x 5 reflector module positions), while the manual version of Axiovert 200 MAT can save 18 combination parameters (6 objective lenses x 3 variable optovar positions).
Digital imaging system: excellent overall advantage
An important member of your team: Axiovert 200 MAT, Together with digital cameras and software, form a powerful imaging system. In addition, it is also a perfect embodiment of Carl Zeiss' values, which are to provide complete solutions for customers' research and practical work based on their actual needs, including support for microscopes, digital cameras, and software technology that meet the most stringent requirements and highest standards.
Position encoding or automatic multiplier Optovar: higher efficiency
New solution: So far, the software cannot automatically recognize the magnification settings or add rulers to the image. The Axiovert 200 MAT and Axiovert 200 M MAT microscopes provide you with a solution. Both types of mirrors can display the total magnification. The measurement software is always able to display the current setup status of the microscope. You can feel the following advantages: precise use of the ruler, fast and error free work.
Digital Camera: Actual Requirements
All types of cameras, whether analog or digital, can be connected to the camera barrel of the Axiovert 200 MAT. AxioCam HR is perfect for microscopic scanning. This digital camera has ultra-high scanning resolution when using low magnification objectives, providing you with both a large field of view and high resolution. If we consider the price factor, another important option is the Axio Cam MR. The two types of products manufactured by Carl Zeiss, J 肷\Langlian 诜 Zhiyuan Province 18, are used to unload the persimmon Kang rabbit outfitting and the gap pod. They are used to punish frozen and bald spots, stains, and obstacles, and are used to unload the V せ loop ∏逦 rabbit condyle love and durability. S is used to pay respects, cut and flash, and Na Gua is tired and confused. The Axiovert 200 MAT is a revolutionary solution for digital imaging.
AxioVision: Specially designed for material microscopy image analysis
AxioVision has established new standards in image processing, image analysis, and file management. The software adopts a harmonious and original modular design, which can meet the basic requirements of digital images and expand to complex advanced applications suitable for material microstructure research. AxioVision has many advantages: a freely configurable menu, reliable reproducibility, automatic saving of complex operation processes, and excellent Carl Zeiss ZVI image format that automatically saves all image parameters. AxioVision is based on the pursuit of excellence and strives for excellence, creating the highest possible performance, simplest operation, most comprehensive flexibility, and seamless integration with Carl Zeiss microscopes and imaging systems. Compared to similar software, AxioVision's features are 100% effective, whether in the basic or advanced versions.
Laser scanning, with superior performance
LSM 5 PASCAL, with its blue and green laser, excellent confocal system, and powerful software, is a powerful tool in the field of materials. It can be used to read and write songs, songs, songs, songs, songs, songs, songs, and other related content? middot; Zeiss' LSM 5 PASCAL, together with Axiovert 200 M MAT microscope and high-performance EC Epiplan-Nofluar objective, provides new and stunning research results, ensuring the reliability of data in industrial and research fields.
Reflection mode: accuracy ranging from micrometers to millimeters
LSM 5 PASCAL is a system specifically developed for work groups, suitable for the needs of materials research and production. Under reflected light, this system is particularly suitable for two-dimensional and three-dimensional analysis of surface morphology of structures with height differences ranging from micrometers and below to millimeters.
Compare and then make a decision
|
|
Axiovert 200 MAT |
Axiovert 200 M MAT |
|
Microscope body |
High stability pyramid shaped structure, low center of gravity, no vibration during operation, at least 6 interface options (with 12 reserved hole positions) |
|
|
Encoding, three hole Optovar converter |
Automatic, three hole Optovar converter |
|
|
Encoding, Six Hole HD DIC Objective Converter |
Encoding, Six Hole HD DIC Objective Converter |
|
|
Z-axis focusing |
Harmonic drive, coarse to fine ratio=50:1 |
Automatic harmonic drive, minimum step size: 25nm, coarse to fine ratio=10:1 |
|
optical system |
IC2S optical components, with fine image quality, provide dedicated long working distance objective lenses |
|
|
objective lense |
Reflected light: Epiplan, EC Epiplan-Neofluar |
|
|
Contrast technology |
Reflected light: bright field, dark field, linearly polarized light, circularly polarized light and their interference contrast, fluorescence |
|
|
modular |
Polarization optical shearing interferometer (TIC), used to measure the optical path difference (horizontal, height) of structures under reflected light, microhardness attachment MHT10, etc |
|
|
lighting |
12V 100W halogen lamp |
|
|
Reflective light using color filter slide ruler |
3 positions, using a 25mm diameter color filter for quick and accurate positioning |
|
|
Aperture slider |
Adjustable aperture stop and field stop for use in reflected light Kohler illumination |
|
|
Function converter |
5-hole, manual, replaceable on both sides |
5-hole, manual or automatic, replaceable |
|
Light trap technology |
Improve contrast and minimize stray light interference |
|
|
Illuminator adjustment knob |
Adjustment of lighting fixtures |
|
|
Conversion operation |
Easy to use, protecting the eyes from harm |
|
|
Transmitted light
|
6 V 30 W |
|
|
|
Axiovert 200 MAT |
Axiovert 200 M MAT |
|
|
Observation tube |
|||
|
Binocular tube |
Equipped with a light shutter to avoid interference from stray light from the eyepiece |
||
|
Binocular camera tube |
Equipped with optical shutter and built-in focusing Bertrand optical components |
||
|
Ergonomic lens barrel |
Equipped with optical shutter and built-in focusing Bertrand optical components |
||
|
eyepiece |
|||
|
PL 10x/23 |
23mm field of view diameter |
||
|
E-PL 10x/23 |
23mm field of view diameter for high-quality observation |
||
|
Carrier platform |
|||
|
Mechanical stage |
Flat surface, wide range travel: 130 × 85 mm, with sample clamp |
||
|
Sliding stage (Z) |
Accurate and free positioning, especially in microscopic operations |
||
|
Automatic scanning stage |
Travel 120 × 100 mm, with sample holder (similar to mechanical stage) |
||
|
Carrier platform (250 × 230mm) |
Equipped with left and right sample rails, travel range: 130 × 85mm, with various sample clamps |
||
|
TV optical port |
|||
|
Border light entrance |
Spectral analysis |
||
|
2 x Left |
100%vis:0%doc/0%vis:100%doc |
–––––– |
|
|
3 x left |
100vis:0%doc/50vis:50doc/0%vis:100%doc |
Same as Axiovert 200 MAT automatic |
|
|
3 x Right |
100vis:0%doc/50%vis:50doc/0%vis:100%doc |
Same as Axiovert 200 MAT automatic |
|
|
3 x Right+Left |
100%vis:0%doc/0%vis:100%li./0%vis:100%re. |
Same as Axiovert 200 MAT automatic |
|
|
Front light port |
Digital camera adapter, optional |
||
|
Bottom light port of the mirror body |
Optional, 60 type interface, used for digital cameras |
||
|
Dual video adapter |
Used for each 60 type interface, with two optical ports (one of which can be adjusted in the x, y, z directions) and a replaceable splitter. |
||
|
Spotlight lens |
|||
|
Numerical aperture 0.55, WD**=26mm |
Used for H, Ph1, Ph2, Ph3, DIC, Manual* |
Used for H, Ph1, Ph2, Ph3, DIC, Automatic* |
|
|
Numerical aperture 0.8, WD**=7mm |
Used for H/DIC Ph1, D, Manual* |
|
|
|
Numerical aperture 1.4, oil immersed |
Used for H, Ph, DIC, Manual* |
|
|
|
Numerical aperture 0.9, WD**=1.0 |
Used for H, D, Ph, DIC, Manual* |
|
|
*Can also be used for Axiovert 200 M MAT microscope
WD * *=working distance
Other specifications can be customized as needed.