The nitrogen sealing device is mainly used for constant control of nitrogen pressure at the top of the storage tank to protect the materials inside the tank from nitriding and ensure the safety of the tank.
The nitrogen sealing device consists of two main parts: ZZDQ quick release valve and ZZV micro pressure regulating valve. The quick release valve consists of a pressure controller and a ZMQ-16K single seat shut-off valve.
When the pressure inside the storage tank rises to the set pressure, the quick release valve quickly opens to release excess pressure inside the tank. When the pressure inside the storage tank decreases, the micro pressure regulating valve opens and fills the tank with nitrogen gas. As the micro pressure regulating valve must be used at a pressure below 0.1Mpa and the on-site pressure is high, ZZYP type pressure regulating valve must be installed to reduce the pressure to below 0.1Mpa before it can be used. The nominal pressure is 0.1Mpa, and the pressure can be set in sections from 0.5Kpa to below 66Kpa. The medium temperature is ≤ 80 ℃.

Product features:

The nitrogen sealing device is convenient for setting the supply (discharge) nitrogen pressure and can be operated under continuous production conditions;
The nitrogen pressure setting range is wide, ranging from as low as 0.5Kpa (50mm. w. c) to as high as Kpa, with a ratio of 132 times. The effective area of the pressure detection diaphragm is large, the set spring stiffness is small, and the action is extremely sensitive.
Adjustment:
Nitrogen supply pressure adjustment: Select a set value within the pressure adjustment range of ZZV type micro pressure regulating valve, such as 1Kpa (100mm. w. c), and adjust screw 2 to change the pre compression (tension) amount of spring 3 to achieve it;
Nitrogen release pressure adjustment: In the pressure controller section of the ZZDQ quick release valve, adjust seat 3 to change the pre compression amount of spring 4. Generally, to avoid frequent opening and closing of nitrogen sealing devices, the nitrogen release setting value should be far away from the nitrogen supply pressure value, such as 2Kpa (200mm. w. c);
Adjustment of high set value of breathing valve: After adjusting the above two set values, in order to avoid frequent opening and closing of the breathing valve, the set value of the breathing valve should be greater than the pressure relief set value.

Material of parts:

Part name

material

valve body

ZG230-450ZG1Cr18i9Ti

Valve stem, valve core, valve seat

1Cr18i9Ti

diaphragm

Nitrile rubber clip reinforced polyester fabric

spring

60Si2Mn

corrugated tube

1Cr18i9Ti

Technical parameters:

Nominal DiameterDN(mm)

20

25

32

40

50

65

80

100

Rated flow coefficient(KV)

8

11

20

32

50

80

100

160

Rated travel(mm)

6

8

10

15

20

nominal pressurePN(Mpa)

0.10

Pressure regulation range(KPa)

0.5-5.5, 5-10, 9-14, 13-19, 18-24, 23-28
27-33, 31-38, 36-44, 42-51, 49-58, 56-66

Medium temperature (℃)

80℃

Adjustment accuracy (%)

±10

Allowable leakage amount(L/h)

10-4 × rated capacity of valve

Specification, weight, and external dimensions:

Nominal DiameterDN

20

25

32

40

50

65

80

100

A

192

232

308

H

629

631

652

666

689

797

837

1050

L

150

160

180

200

230

290

310

350

G(Kg)

18

19

21

23

25

37

50

59

Flange specification unit: mm

Nominal DiameterDN

20

25

32

40

50

65

80

100

D

105

115

140

150

165

185

200

220

D1

75

85

100

110

125

145

160

180

B

16

18

20

22

n-ф

4-14

4-18

8-18

f1×D2

2×56

3×65

3×76

3×84

3×99

3×118

3×132

3×156

Installation matters:

(1) Before installation, check whether the parts of the whole machine are damaged or loose, clean the pipelines, and ensure that the flow direction of the medium is consistent with the arrow on the valve body.
(2) For the convenience of on-site maintenance and operation, appropriate space should be left around the valve and a bypass manual valve should be installed. The installation plan for the valve group.
(3) The valve should be installed upright and vertically on a horizontal pipeline, and the valve body should be connected to the pipeline in a coaxial manner. It should be installed in an environment where the ambient temperature does not exceed -25~55 ℃.