Submerged sewage pump (double pipe)
Submerged sewage pump (single pipe)


Detail image:

Head motor end:

If you have any questions, you can call: 021-57239999 orClick to consult experts for selection and quotation
Product details of submersible sewage pump:
Brand: Shanghai Gaotian
Model: 150YW200-10-15
Material: Cast Iron
Drive mode: electric
Principle: Centrifugal pump
Pump shaft position: side vertical
Impeller suction method: single suction
Number of impellers: 1
Impeller structure: closed single channel
Scope of application: Petroleum, chemical, pharmaceutical, papermaking, metallurgy, wastewater treatment
Product alias: YW submersible pump
Flow rate: 200 (m3/h)
Lift: 10 (m)
Common faults and solutions:
|
Fault phenomenon |
cause analysis |
Troubleshooting |
|
Insufficient flow or no water output |
1Wrong rotation direction of impeller 2Is the outlet valve open and intact 3The impeller of the pipeline is blocked 4The speed is too low 5The head is too high 6High density of pumping medium 7High viscosity of the medium 8Wear at the sealing ring mouth
|
1Adjust the rotation direction of the impeller 2Check, repair, and eliminate 3Clean up debris 4Check electrical equipment and circuits 5Change the pump or reduce the head 6Dilute with water to reduce concentration 7Reduce viscosity 8Replace
|
|
Unstable operation |
1Unbalanced impeller 2Bearing damage
|
1Send to the manufacturing plant for replacement or calibration 2Replace
|
|
The pump cannot start |
1Lack of phase 2The impeller is stuck 3Winding, connector or cable open circuit 4The stator winding is burnt out 5Electrical control malfunction
|
1Check the circuit for repair 2Remove debris 3Check and repair with an ohmmeter 4Repair and replace the winding 5Repair or replace
|
|
Excessive current |
1Low working voltage 2Pipeline and impeller are blocked 3The height or viscosity of the liquid being pumped is relatively high 4Using a low head
|
1Adjust the working voltage 2Clean up pipeline and impeller blockages 3Change density and viscosity 4Reduce flow and increase head
|
|
Low insulation resistance |
1Leakage at the power supply terminal of the cable 2Cable damage 3Mechanical seal wear leads to leakage 4EachOFailure of the sealing ring 5The casing is corroded by the medium and leaks water
|
1Tighten the compression nut 2Replace 3Replace 4Replace 5Repair
|
If you have any questions, you can call: 021-57239999 orClick to consult experts for selection and quotation