VIP member
YN194I-9X1 single-phase digital ammeter
● Measurement: Single phase current ● Display: A row of digital tubes (LEDs) display STN blue screen, wide viewing angle, high-quality, high-definitio
Product details

| PRODUCT MODEL | measure | display | Peripheral functions | |||
| rs485 communication | analog output | Switching input | ALARM IN | |||
| YN194I-9X1 | Measurement: I | Single row: LED | not have | not have | not have | not have |
| YN194I-9K1 | Optional | Optional 1AO | Optional 1-2DI | Optional 1-2DO | ||
| YN194I-9KY | Single row: LCD | |||||
characteristic:
Measurement: Single phase current● Display: A row of digital tubes (LEDs) display STN blue screen, wide viewing angle, high-quality, high-definition LCD screen display.
Communication: RS485 communication, MODBUS-RTU protocol. It has networking communication function.
● Input: 2-channel switch input (2DI).
Output: 2-channel switch output (2DO), 1-channel analog output (3AO).
Expansion: AC5A and above require current transformers
summary:
The digital intelligent single-phase meter is used for measuring and displaying electrical parameters such as current, voltage, frequency, active power, reactive power, and power factors in power grids and automation systems. By setting the magnification on the panel, it intuitively displays the operating point parameters of the primary side of the system. It has the advantages of high accuracy, good stability, and anti vibration, and can directly replace the original pointer instruments.Technical indicators:
| performance | parameter | ||
| transport enter measure measure apparent show |
electric current | RATING | AC5A (other specifications, please specify when ordering) |
| overload | Overload: 1.2 times instantaneous: 10 times/10 seconds | ||
| power consumption | < 0.4VA (per phase) | ||
| impedance | >2MΩ | ||
| accuracy | RMS measurement, accuracy level 0.5 | ||
| power supply | scope of work | AC/DC85~270V | |
| power consumption | ≤5VA | ||
| output | Digital Interface | RS485, MODBUS-RTU protocol | |
| environment | work environment | -10~55℃ | |
| Environment | -20~75℃ | ||
| secure | pressure resistance | Input/power>2kV, input/output>2kV, power/output>1kV | |
| isolation | Input, output, and power supply to the chassis>50M Ω | ||
Wiring method:

Additional features:
Example of ordering:
When signing the contract, please provide detailed information such as product model, input signal, wiring method, etc. This series of products comes with a default appearance setting as standard. If customers have special requirements, please specify them in detail in other projects.Model: YN194I-9X1 (single-phase ammeter)
Input: AC5A
Communication interface: RS485/MODBUS-RTU
Online inquiry