YLDL-211 distribution line single-phase grounding fault point locator is used for locating single-phase grounding fault points in 6kV, 10kV, 20kV, and
Product details
YLDL-211配网线路接地故障定位仪

brief  



YLDL-211Single phase grounding fault point locator for distribution linesUsed for locating single-phase grounding fault points in 6kV, 10kV, 20kV, and 35kV overhead lines. For hidden grounding faults such as porcelain bottle breakdown and lightning arrester breakdown, the search is fast, time-saving and labor-saving, and can shorten the search time by 60%.


 YLDL-211 配电线路单相接地故障点定位仪



Product functions and features  



Search quickly and accuratelyAdopting a multi evidence fusion fault location discrimination technology based on time sequence and phase, it is not affected by measurement distance (line height) errors, line length, and number of branches, and the fault point error does not exceed 1 meter
Wide applicabilityMulti mode measurement technology, suitable for locating various types of grounding faults (including low resistance grounding, high resistance grounding, arc grounding, and hybrid grounding)
Easy to carry and useThe signal source is powered by lithium batteries, which are small in size, light in weight, and easy to carry. It comes with its own power supply, does not require a generator, and can be charged in vehicles
Safe and reliable operationThe operator operates through an insulated rod, and the device is equipped with overvoltage protection inside to ensure safe operation


Product Technical Parameters  



Output AC detection current: 0~40 ± 2mA
Output AC detection voltage: 0~3kV
Output DC grounding impedance current: 0~37 ± 2mA
Output DC grounding impedance voltage: 0~4.2kV
Output power: Effective maximum output power of 95W
Measurement range: Grounding resistance ≤ 100k Ω
Detection line length: ≤ 100km
Grounding impedance measurement: 0-2000 k Ω
Grounding impedance measurement accuracy: 10% ± 2k Ω
Device size: (mm) L457 * W370 * H184
Device weight: 11.3Kg


Technical specifications for pliers and hand readers  



Detection method: clamp CT, integration method
Transmission method: 433MHz wireless RF transmission, with a transmission distance of about 30m
LCD size: 62mm × 44mm
Device size: Length 100mm x Thickness 35mm x Height 204mm
Sampling frequency: 2 times/second
Resolution: 0.1mA
Jaw size: Ø 50mm
Test accuracy: ± 2% ± 5dgt (23 ℃± 5 ℃, below 80% RH)
Measurement range: 0.1mA to 1200A (50Hz); 0.1 mA~200 mA(22Hz)