specifications |
Cable reference data |
||||
Nominal cross-sectionmm2 |
Core structure |
Nominal outer diametermm |
Reference weightKg/Km |
20At ℃, the conductor resistance is not greater thanΩ/Km |
Long term continuous load allowable current carrying capacity |
10 |
322/0.20 |
8.3 |
146/237 |
1.91 |
75 |
16 |
513/0.20 |
9.9 |
219/237 |
1.16 |
105 |
25 |
798/0.20 |
11.3 |
314/335 |
0.758 |
135 |
35 |
1121/0.20 |
12.5 |
419/442 |
0.536 |
170 |
50 |
1596/0.20 |
14.6 |
583/615 |
0.379 |
215 |
70 |
2220/0.20 |
16.9 |
798/839 |
0.268 |
265 |
95 |
2997/0.20 |
19.2 |
1059/1111 |
0.198 |
325 |
1)Applicable occasions:
model |
name |
YH |
Natural rubber sheathed welding machine cable |
YHF |
Chloroprene or other equivalent synthetic rubber elastomer sheathed welding machine cable |
2) Usage characteristics: It is particularly soft and has good bending performance.
The sheath material adopts a mixture of natural rubber or chloroprene rubber, which can be suitable for different occasions.
The chloroprene rubber composite sheath has heat resistance, oil resistance, and non flame retardant properties.
This product is suitable for secondary side wiring and connecting welding machines with ground voltage AC not exceeding 200V and pulsating DC peak 400V.
The maximum working temperature of the cable is 65 ℃
model |
rated voltage |
CORE |
section(mm 2 ) |
standard |
YH、YHF |
Not required |
1 |
10-185 |
GB5013.3-1985 |
Electromagnetic flowmeter K-type thermocouple thermal resistance bimetallic thermometer pressure transmitter flow transmitterHigh temperature resistant and fire-resistant cable