WRNR-15 hot sleeve thermocouple
Ten years of sharpening a sword, actively striving for excellence, only for you with high quality
|
Overview Summary
Hot sleeve thermocouples are mainly used to measure the temperature of steam pipelines and boilers. |
★ Thermoelectric thermocouple temperature sensing element
Purpose: It can be used directly as a thermocouple or as a component for repairing and replacing hot sleeve thermocouples.
| name | model | Graduation | Length Lmm |
| Single temperature sensing element | WRNT-001 | K | 250 800 300 850 350 900 400 950 450 1000 500 1050 550 1400 600 2270 700 3200 750 3500 |
| Dual branch temperature sensing element | WRNT2-001 | ||
| Single temperature sensing element | WRNT-001 | E | |
| Dual branch temperature sensing element | WRNT2-001 |
★ Medium temperature and medium voltage thermocouple
| name | model | Graduation | Measuring range | nominal pressure | velocity of flow | Protective tube material |
| Single thermocouple | WRNR-14 | K | 0~340℃ | ≤29.4MPa | ≤30m/s | 1Cr18Ni9Ti stainless steel |
| WRNR-14 | E | |||||
| Dual thermocouple | WRNR2-14 | K | ||||
| WRNR2-14 | E |
Insertion length I (mm): 50100150.
When I ≤ 100mm, the protective tube can be used for 600 ℃.
★ Low temperature and low pressure thermocouple
| name | model | Graduation | Measuring range | nominal pressure | velocity of flow | Protective tube material |
| Single thermocouple | WRNR-15 | K | 0~260℃ | ≤2MPa | ≤9m/s | Protective tube (III) M33×2 |
| WRNR-15 | E | |||||
| Dual thermocouple | WRNR2-15 | K | ||||
| WRNR2-15 | E | |||||
| Single thermocouple | WRNR-15A | K | Protective tube (IV) ZG1”(NPT”) |
|||
| WRNR-15A | E | |||||
| Single thermocouple | WRNR2-15A | K | ||||
| WRNR2-15A | E |
|
Protective tube material: 1Cr18Ni9Ti stainless steel
Enterprise Honor and Qualification
On site map of equipment factory
Customers use on-site maps
Buyers must-read
Shipping Notice
|