The WQK/belt cutting device sewage pump has a particularly strong sewage passing capacity and good cutting performance. It can chop up impurities such
Product details

Overview of WQK/QG Sewage Pump with Cutting Device

The WQK/belt cutting device sewage pump has a particularly strong sewage passing capacity and good cutting performance. It can chop up impurities such as long fibers, plastics, paper, belts, cloth strips, straw, ropes, etc. in the sewage and discharge them. It adopts advanced methods and is designed with reasonable hydraulic characteristics, so that the electric pump can operate at full head. The excellent combination of dry motor and water pump makes the total efficiency of the electric pump reach the same level as the ASS belt cutting device series products of West German ABS company. The electric pump adopts high-quality hard alloy, double end mechanical seal and skeleton oil seal assembly surface, which should not exceed 1/2 of the height of the motor, and the temperature of the pumped waste should not exceed 40 ℃.

The WQX series submersible sewage pump is mainly used for discharging domestic wastewater, sewage, human feces and urine, as well as solid suspended solids and non corrosive media containing short fiber paper scraps, sawdust, starch, sediment, ore particles, etc. The temperature of the pumped liquid does not exceed 40 ℃, the density does not exceed 1200kg/m3, and the pH value is about 9. This electric pump adopts a double end mechanical seal and a rotating impeller. The impeller is made of stainless steel, wear-resistant, non clogging, non winding, and has the advantages of small volume, compact structure, and easy portability.

Scope of application for WQK/QG sewage pump with cutting device

The WQK/QG sewage pump with cutting device is mainly used for engineering sewage and domestic sewage.

(1) Used for construction sites, engineering foundation construction, municipal facilities, and water treatment plants.

(2) Sewage discharge from the basement of various high-rise buildings, civil air defense pits, subways, and other underground structures.

(3) Sewage treatment and circulating water transportation for small and medium-sized enterprises.

(4) The pumping of slag and slurry from factories and mining enterprises such as food, paper, brewing, steel and non-ferrous metals, leather, textile, pharmaceutical, cement plants, etc.

(5) Chicken farms, pig farms, various animal husbandry industries, fish ponds are used for pumping and cleaning ponds, oxygenation, septic tanks, and other occasions for the transportation of human and animal manure and urine.

Note: The main performance and data of the wqk sewage pump with cutting device are the same as those of the wqk/qg type, except for the absence of cutting device.

WQK/QG with cutting device sewage pump model meaning


model

internet traffic
m3/h

lift
(m)

Diameter of outlet piping
mm

power
kw

rotational speed
(r/min)

WQK8-12QG

8

12

32

0.75

2900

WQK20-7QG

20

7

50

0.75

1450

WQK10-12QG

10

12

40

1.1

1450

WQK8-22QG

8

22

25

1.1

1450

WQK20-15QG

20

15

50

1.5

1450

WQK15-30QG

15

30

40

2.2

1450

WQK20-20QG

20

20

50

2.2

1450

WQK25-15QG

25

15

65

2.2

1450

WQK40-7QG

40

7

80

2.2

1450

WQK30-15QG

30

15

80

3

2900

WQK25-30QG

25

30

65

4

2900

WQK40-15QG

40

15

80

4

1450

WQK85-10QG

82

10

100

4

1450

WQK65-25QG

65

25

80

7.5

2900

WQK80-20QG

80

20

80

7.5

1450

WQK100-15QG

100

15

100

7.5

1450

WQK100-25QG

100

25

100

11

1450

WQK115-15QG

115

15

125

15

1450

WQK180-15QG

180

15

150

15

1450


Precautions for use

(1) Before using the electric pump, it is necessary to first check whether the cables are damaged. When handling and installing the water pump, cut iron to pull or damage the cables to prevent accidents caused by cable breakage and water leakage. If the cable cracks hard, it should be replaced immediately. And use a megohmmeter to check if the insulation resistance of the electric pump is normal (the insulation resistance should not be less than 1 megohm)

(2) Identify the grounding wire (usually yellow or green or marked with a grounding symbol), and follow the prescribed procedures to properly connect the grounding wire. Our factory's grounding wire is equipped with a grounding sign.

(3) Choose appropriate protectors (such as leakage protectors, air switches, phase failure overcurrent protectors, etc.) and do not directly connect them with knife switches.

(4) Connect the power cord according to the standard, test the power supply, check if the electric pump is running normally, and determine if the steering is correct. If the steering is incorrect, swap any two of the three power cords (note that the running time should not exceed half a minute).

(5) Install the water outlet connector and water outlet hose (or iron pipe), tie a rope on the electric pump handle (never use a cable to replace the hanging rope), place the electric pump into the pump to be pumped, turn on the power, and it can be used.

(6) In order to ensure personal safety, it is strictly prohibited to install water operations (such as moving, inspecting, troubleshooting, etc.) near the electric pump during the operation of the electric pump. Contact with the electric pump is necessary to prevent accidents caused by electric pump leakage!

(7) It is strictly prohibited to expose the entire electric pump to the water surface for long-term (or short-term) operation. The "on" and "off" of the electric pump should not be too frequent to prevent motor overheating and damage

(8) Long term pumping of liquids with high sand content causes significant wear on the overcurrent components of the WQK/QG belt cutting device sewage pump. It is recommended to use our factory's cyclone sewage submersible electric pump product.

(9) If it is found that the WQK/QG sewage pump with cutting device does not rotate, the protector trips, the fuse burns out and other abnormal phenomena occur during operation, the power should be cut off immediately, and the wiring of the power protector should be checked for any problems. If these external devices are all normal, it may be a fault with the electric pump, and it should not be continued to be used to avoid accidents!

Cause and solution of malfunction

Fault phenomenon

Reason for malfunction

solution

The electric pump is not running

The power cord is not properly connected

Connect the power supply according to standard requirements

One phase of the power supply is not powered on

Check the fuse and power supply, connect the three-phase power supply

Impeller and chassis stuck

Adjust the chassis clearance between 0.2-0.5mm so that the impeller can be easily moved by hand

Electric pump burnt out

Repair the motor again

Damaged protective device

Repair or replace

Small water output or insufficient head

The clearance between the impeller and the chassis is too large

Adjust the gap to the normal range (0.2-0.5mm)

The impeller is severely worn out

Replace the impeller

The motor speed cannot reach the normal speed

Replace the motor rotor or repair the voltage

The power supply voltage is too low

Adjust the voltage to the rated voltage

Reduce the voltage drop on the power leads of large cross-section cables (in cases where the power leads are too long)

Reverse rotation of electric pump

Swap the two power connectors to make the electric pump rotate forward

Impurities cannot be cut or
Poor cutting effect

The clearance between the impeller and the chassis is too large

Adjust the gap to the normal range (0.2-0.5mm)

Cutting blade wear becomes pure

Replace the impeller and chassis

Protector is disconnected or
Connected and then disconnected

Improper selection or damage of protector

Re select a suitable protector (the rated current of the protector must match the rated current of the electric pump)

The insulation resistance of the power motor is too low (less than 0.5M Ω) due to moisture or water leakage

Remove the motor for drying. If the mechanical seal, sealing ring, or cable sealing head is damaged and leaks water, the damaged sealing components should be replaced

Short circuit between turns of motor stator coil

Replace or repair the motor again

Two phase operation of motor

Check the power supply or connectors, repair them

The power supply voltage is too low

Restore the voltage to normal value

The electric pump is stuck by impurities

Clean up impurities

Excessive viscosity or sand content in water can cause overload operation of the electric pump

Reduce viscosity or sand content

Bearing damage

Replace bearings