P5100 VOCs Full Component Online Monitoring System
·Provide a full range of products from NMHC online analyzer to VOCs full component analyzer
·Meet all VOC analysis requirements from ambient air to pollution sources
·Configure a fully automatic sample dilution device, all analyzers can be automatically calibrated
·Integrated cabinet type hydrogen generator and air generator
·Configurable dedicated air hydrocarbon removal device
·Support remote diagnosis and maintenance
This system has the following characteristics:
- The use of two-stage enrichment/reverse column technology to enrich low boiling point components not only improves the enrichment efficiency of low boiling point components, but also eliminates the influence of moisture and high boiling point organic matter.
- Capillary chromatography column heating system, low heat capacity, fast heating speed, and good chromatographic peak shape. Compared with traditional furnace control methods, the column heating system.
- The detector has high sensitivity, stable performance, linear range>107, * small detection limit<0.03 ppb (benzene)
- Fast analysis speed, it takes about 30 minutes to complete a VOC full component measurement. Usually, using a conventional gas chromatograph requires at least 1 hour or more.
- Programmable 10 segment linear heating with fast heating rate
- The system adopts full circuit EPC (Electronic Pressure and Flow Control System) control, with high degree of automation, simple operation, and high reliability. At present, similar products abroad are still mainly controlled manually. The electronic flow pressure technology used in this project not only improves the automation level of the system, but also effectively enhances its reliability.
P5100 series analyzerIncluding accessories such as cabinets, analyzers, standard diluents, and related gas generators. Due to the standard cabinet design of the P5100 series analyzer, all devices can be easily integrated into one system. At the same time, cooperate with Xuan YiD2100 Fully Automatic Sample Dynamic Dilution SystemThe system can automatically periodically updateinstrumentPerform calibration and inspection. Customers can also observe the status of the instrument in real-time through the status lights on the instrument panel. Xuanyi has different models of analyzers that meet the requirements for the composition and detection limit of volatile organic compounds in different standards and testing requirements. Users can configure the appropriate model of analyzer based on this
P5100-NMHC methane non methane total hydrocarbon online analyzer
| Instrument model | Analyze the components | Detection limit and sample pretreatment |
| P5100-NMHC1 | Methane and non methane total hydrocarbons | Ppb level, improvement plan based on national standard, direct measurement of non methane total hydrocarbons |
| P5100-NMHC2 | Methane and non methane total hydrocarbons | Ppb level, basically the same as the national standard method, measuring total hydrocarbons and methane and then subtracting them |
The above two types of non methane total hydrocarbon online analyzers. The P5100-NMHC1 analyzer adopts the direct measurement method. Provide direct measurement of the concentrations of methane and non methane components without the need for any calculations or conversions. The method equipped with this model can eliminate the interference of oxygen in the air and accurately measure the low content of non methane total hydrocarbons, while avoiding the accuracy problems that may arise from traditional subtraction methods.
The P5100-NMHC2 analyzer uses traditional subtraction method. This model of analyzer uses hydrocarbon free air as the carrier gas to measure the total hydrocarbon and methane values, and then subtract the difference to obtain the non methane total hydrocarbon value calculated as methane (or other components). All analysis and calculations are automatically completed by ProChrom software.
P5100-VOC Full Component Online Analyzer
| Instrument model | Analyze the components | Detection limit and sample pretreatment |
| P5100-VOC | C2-C12+ | PPT level, including sample pre concentration |
| P5100-VOCL | C2-C6 | PPT level, including sample pre concentration |
| P5100-BTEX | C6-C12+ | PPT level, including sample pre concentration |
| P5100-VOC-N | C2-C12+ | Ppb level, direct measurement without concentration |
| P5100-VOCL-N | C2-C6 | Ppb level, direct measurement without concentration |
| P5100-BTEX-N | C6-C12+ | Ppb level, direct measurement without concentration |
| P5100-VOC-SP | Universal customized models | According to customer requirements and standard configuration |
Asicotech's P5100-VOC is a true full component analyzer in the market. With just one host, users can simultaneously analyze all components of C2-C12+volatile organic compounds, such as the 56 components specified by PAMS or all components specified by TO-18, TO-17, TO-15, and TO-14. And all similar instruments from other manufacturers must use at least two instruments to test C2-C6 and C6-C12+respectively. This is mainly due to Xuan Yi's full range SEPC electronic pressure and flow control system, compact low-temperature adsorption technology, and low heat capacity chromatographic column heating system.
Typically, a full component analyzer includes an online adsorption/desorption instrument, dual capillary chromatography columns, dual FID detectors, and a valve injection system. Customers can choose to configure different modules based on the range and detection limit requirements of the analyzed components. For specific information, please consult Asicotech for engineers.
D2100 Product Model Description
| Instrument model | function | Basic parameters |
| D2100 | Dilute the sample standard gas at different multiples to the desired concentration | *The dilution ratio can reach 2500:1 |
| D2100-S | On the basis of the basic model, Silcotek inerting treatment can be applied to the sample pipeline to produce ppb level sulfides or other easily adsorbable samples | *The dilution ratio can reach 2500:1 |
| D2100-N | D2100 can be used as a multi-channel gas mixing device | Users can create mixed standard samples as needed |
- N: The numbers 1-3 represent the number of sample gases embedded in the same device, and * can integrate 3 sample gases simultaneously to make mixed standard gases
- The dilution system uses a high-precision mass flow controller to provide dilution gas, which is mixed with sample gas to provide samples of various concentrations for regular instrument calibration and performance testing. Users can produce the required standard gas by diluting it in different proportions while mixing a concentration standard sample. This system supports multiple types of diluents, such as nitrogen (N2), air (Air), helium (He), etc.
Other Auxiliary Equipment
| Instrument model | function | Basic parameters |
| D1000 | Filter hydrocarbons in the air to ppb level | Adopting high-temperature catalytic method and standard cabinet design, it supports long-term continuous operation and uninterrupted filtration of 3L/min air. Usually used for the carrier gas system of P5100-NMHC2 methane/non methane analyzer. |
| H1000 | Online hydrogen generator | Using electrolytic pure water method, continuously providing chromatographic grade hydrogen gas (providing different levels such as 150ml/min, 300ml/min, etc.) |
| A1000 | Online air generator | Continuously provide chromatography grade compressor air (with different levels such as 3L or 8L) to ensure the analyzer can operate reliably for a long time, and the accessories configured in the cabinet must also withstand the test. All accessories used by Xuanyi have undergone rigorous on-site testing to ensure that they can enable the relevant analyzers to perform at their best. |