The V230Y self operated pressure regulating valve consists of a valve body, valve seat, valve core components, etc. It is an energy-saving product that does not require external energy and relies solely on the pressure changes of the regulated medium to automatically regulate pressure. It can be used as a pressure control device for non corrosive liquids, gases, steam and other media. Compared with ZZYP, the control spring is less affected by medium temperature due to its distance from the valve body, and is easier to replace or adjust Therefore, it is widely used in industrial sectors such as petroleum, chemical, metallurgical, and light industry, as well as urban heating and heating systems. This product has a nominal pressure of PN16 and 40, a nominal diameter range of 20-300mm, and an operating temperature of ≤ 350 ℃. There are a variety of varieties to choose from. It has a larger pressure difference range than the old model.
Main component materials
Valve body: ZG230-450, ZG1Cr18Ni9Ti, ZGCr18Ni12Mo2Ti Valve core: 1Cr18Ni9Ti, Cr18Ni12Mo2Ti Valve seat: 1Cr18Ni9Ti, Cr18Ni12Mo2Ti Valve stem: 1Cr18Ni9Ti, Cr18Ni12Mo2Ti Membrane cover: A3, 1Cr18Ni9Ti Packing: polytetrafluoroethylene, flexible graphite membrane: nitrile rubber, oil resistant rubber, fluororubberTechnical Specifications
Nominal diameter DN (mm)20253240506580100125150200250300Rated flow coefficient Kv7112030487512019030048076011001750Rated travel L (mm)81014202540506070Nominal pressure PN (MPa)1.6, 4.0Pressure regulation range (KPa)15-50, 40-80, 60-100, 80-140, 120-180, 160-220, 200-260
240-300, 280-350, 330-400, 380-450, 430-500, 480-560, 540-620
600-700, 680-800, 780-900, 880-1000, 600-1500, 1000-2500Inherent traffic characteristicsHurry upAdjustment accuracy (%)±5Operating temperature (℃)≤350Allowable leakage amountHard seal (1/h)Single seat: ≤ 10-4 x valve rated capacity (Class IV), double seat and sleeve: ≤ 5 x 10-3 valve rated capacity (Class II)Soft seal (m1/min)0.150.300.450.600.901.704.06.7511.1016.0Pressure reduction ratiomaximum10minimum1.25Installation Instructions
Note: 1. Filter 2. Self operated pressure regulating valve 3. Pressure tapping pipe φ 14 × 2 4. Condensation tank
Overall dimensions

Nominal Diameter
DN20253240506580100125150200250300Flange distance L185200205222254276298352410451600670735Total height H6156456507107307457608008909601050H152.557.567.572.5809097.5107.5122.5140167.5225230d100h280Flange StandardGB:PN 1.6 2.5 4.0MPa ,ANSI:150LB 300LB JIS:10K 20K