VIP member
V13005/ZA3 self operated flow and pressure combination valve
Caliber range: DN15-250mm Pressure range: PN1.6-4.0MPa Applicable temperature: 200 ℃ Product application: V13005/ZA3 self operated flow and pressure c
Product details
-
1、 Product Features
V13005/ZA3 self operated flow and pressure combination valve
V13005/ZA3 self operated flow and pressure combination valveSelf operated flow pressure combination valveIt is an energy-saving multi combination control valve that does not require external energy. It is used as a control device for non corrosive water and other liquid media with a maximum temperature of 200 ℃, flow rate, and pressure. The flow valve is combined with the ZA3 type actuator through a combination control valve.Principle of ActionWhen flow and pressure are combined for control, the valve operates sequentially according to the different input sequences of the flow valve and pressure valve (behind the valve). When either the flow rate or pressure (behind the valve) reaches or exceeds the set value, the valve will operate according to its requirements to meet various control requirements on site.Valve Technical ParametersNominal diameter (DN)1520253240506580100125160200250KVS value (m3/h)16.381620325080125160280320400Flow range (m/h) QS (energy range under effective pressure) of throttle differential pressure (∆ Pb)0.02Mpa0.1-20.2-30.2-40.4-70.6-110.8-163-284-406-638-8012-12515-15018-1800.05Mpa0.2-30.3-4.50.3-60.5-100.8-161.2-244-406-589-9012-12018-18012-22018-250Z value0.60.60.60.550.550.50.50.450.40.350.30.20.2Maximum pressure difference ∆ Pmx (Mpa)Pn161.61.61.61.61.61.61.61.61.51.51.21.01.0Pn402.02.02.02.02.02.02.02.01.51.51.21.01.0Allowable leakage amount(Under specified experimental conditions)hard seal4×10-4Rated capacity of X valve (L/H)soft seal10 bubbles per minute20 bubbles per minute40 bubbles per minuteMain technical parameters of ZA5 actuatorEffective area of actuator (cm)2)250Effective pressure (Mpa) (throttle valve pressure difference ∆ Pb)0.02 0.05Allow maximum pressure difference ∆ Pmax (Mpa) between the upper and lower membrane chambers0.4Set value deviation±5%Control connector \ \ connectorCopper or steel pipe 읂 1 (mm) sleeve type pipe joint R1/4 "Main technical parameters of ZA3 actuatorEffective area of actuator (cm)2)3280250630Valve front pressure control range(Mpa)red spring0.3-1.20.1-0.60.015-0.15Yellow spring0.05-0.30.01-0.070.005-0.035Black spring0.8-1.6Applicable nominal diameter DN (mm)15~12515~250The minimum pressure difference ∆ Pmin (Mpa) required to ensure the normal operation of the pressure valve≥0.05≥0.04≥0.01≥0.005Maximum allowable pressure difference ∆ Pmax (Mpa) between the upper and lower membrane chambers2.01.250.40.15Set value deviation±8%Control pipeline \ \ jointCopper or steel pipe 읂 1 (mm) sleeve type pipe joint R1/4 "
Online inquiry
