1Product Features
1、 AmericaUniBestThe company's two insect detection system has a high sales volume among other manufacturers in the global market.
2、 AmericaUniBestThe company's two insect washing system adopts a new technology of washing, which fully washes the collected filter bags through natural washing mode, which can not only100%Wash out the two insects while ensuring their integrity.
3、 The novel and unique filter bag structure ensures complete interception of two insects and is easy to wash out. It is also more suitable for treating high turbidity water samples, which is in line with China's national conditions.
4、 The design of disposable filter bags avoids cross contamination and ensures the authenticity and effectiveness of the two insect experiment.
5、 Up to24A one month warranty period for reagents can meet the testing needs of customers in the current year and ensure that the reagents are still effective in the next year's testing, thereby maximizing the utilization of reagents and avoiding economic losses caused by short shelf life of reagents, saving costs for units and enterprises.
IIDetection steps
GB 5750.12- 2006Standard Inspection Method for Drinking Water Zhongjiadi flagellates and cryptosporidium
The detection steps are as follows: sampling and filtering→Wash and concentrate→immunomagnetic separation→fluorescence staining→Mirror inspection counting
Step 1: Sampling and filtering

Filter bag characteristics:
1Specially designed for washing two insects, in compliance with Chinese national standardsGB 5749-2006and the united statesEPA, UKDWIAustraliaTGAWait.
2、 0.45μmAperture,100%Capture two insects
3、 Disposable to avoid cross contamination
4、 High voltage resistance
Step 2: Wash and concentrate
Equipment features:
1、 One click fully automatic quick and repeated washing of the collected two insect samples.
2、 Washing time only requires2Minutes, the entire experiment only requires5Hour by hour, no need for post maintenance and upkeep, the world's lightweight and fast washing equipment is suitable for emergency and laboratory operations.
3、 The equipment recycling rate is as high as90%It is currently the two insect detection device with the highest recycling rate in the world.
Step 3: Immunomagnetic Separation
The immune magnetic separation process uses the United StatesUniBestUbaida Company'sClearScanThe series of two insect specific immune magnetic separation kits use magnetic beads with specific antibodies to bind with specific antigens of Giardia and Cryptosporidium in the sample, and efficiently and selectively separate them in a magnetic field. This step ensures the specificity of detection.

Step 4: Fluorescence staining/microscopic examination
Use two insect specific fluorescence microscopes to detect stained samples, observe the samples, and observe the observed objects that meet the size, shape, and fluorescence characteristics of the sporangia and oocysts according to the national standardGB/T 5750.12-2006Qualitative and quantitative analysis of the characteristics of the sporangia of Giardia and Cryptosporidium in China.

3、 Technical parameters
1、 Recovery rate of filtering steps ≥100%
2、 filter/Recovery rate of washing steps≥80%
3、IMSRecovery rate of immune magnetic separation step≥90%
4、 Total recovery rate (filtration, washing, magnetic bead separation, staining)>35%
5、 Relative standard deviation of test results≤10%
6、 Washing pressure:0.5barThe washing process can be quickly completed without the need for compressed air. This advanced washing method ensures that both insects are completely washed away and their complete morphology is maintained.
7、 Detect high turbidity water samples that can be processed:>100 NTU
8、 The reagent kit is equipped with pre made positive control slides to ensure the effective activity of the kit; Completely avoid false positives and ensure the accuracy of testing.
9、 Shelf life: Long shelf life24A month is a longer shelf life and more stable performance in the global industryIFAReagents.
10The filter bag is recyclable and resistant to high pressure
11Water sample processing capacity: the amount of water processed each time≥1000LTap water;≥100LSource water
12Sampling upper limit flow rate:4rise/minute
13Total time for washing steps:2minute
14Filter module structure: including≥100Three porous reticulated foam layers, two different specifications:≥60Three large foam layers, outer diameter42mm, inner diameter34mm;≥40Small foam layer, outer diameter30mm, inner diameter25mm, thickness10mmInteraction stacking.
15Working voltage:220V±10%(AC),50HZ
16Working environment temperature and humidity:5-40℃,5%-95%
4System Overview
|
system |
device |
Main performance and technical indicators |
Application and characteristics of the device |
|
elutriation system |
Fully automatic rapid washing system |
1One click fully automatic quick wash. 2、 Washing time only requires2Minutes, the entire experiment only requires5Hours, no maintenance required, suitable for emergency and laboratory operations. |
High equipment recycling rate90%,It is currently the two pest detection equipment with the highest recycling rate in the world. |
|
Immune magnetic separation system |
UniBestcompany “Two worms”Immunomagnetic Separation Kit |
1、 The program is simple, greatly saving manual operation time. 2、 Even if the content of two insects in each concentrated water sample is low, the magnetic separation recovery rate can still be maintained at90%above. 3、 Can work well with the newly launched next-generation fully automatic washing equipment,Greatly improve the washing efficiency and further enhance the recovery rate of the magnetic separation step. |
1、 Through national standardsGB5749-2006and the united statesEPA-1623Standard validation. 2、 It can significantly improve the recovery rates of Cryptosporidium and Giardia. 3、 It can reduce the background of residual debris during microscopic examination. 4、 as low as1A spore sac/Egg sacs can also be detected. |
|
UniBestcompany Sample mixer |
1The mixing wheel can be placed simultaneously12Only test tubes. 2rotational speed2-40rpmAdjustable, digital display. |
Before the immunomagnetic separation step, mix the magnetic beads with the sporangia to fully bind and improve the recovery rate of the two insects. |
|
|
Magnet Separator (Micro and Large Capacity) |
1Large capacity magnetic separator working volume:5-15mlSpecially designed for use with side flat wall test tubes. 2Micro magnetic separator working volume:1.5mlCan be placed simultaneously6A standard one1.5mlMicro centrifuge tube. |
Magnetic separator is a specialized tool for immune magnetic separation of two insects. When a test tube is inserted into the magnetic separator for magnetic particle concentration, the magnetic beads will be attracted to the test tube wall by the magnetic field. Therefore, the upper clear liquid and impurities can be smoothly removed, separating it from the magnetic beads and two insects. |
|
|
Side flat wall test tube |
Two insect specific side flat wall test tube |
Combined with a large capacity magnetic separator, specifically designed for two insect immune magnetic separation experiments. |
|
|
IFAdye system |
UniBestcompanyIFA (Indirect immunofluorescence) Staining reagent kit |
1Quick and accurate detection. 2、 The cost-effectiveness of the reagent is high, and the use of a special color fixing solution prevents the specimen from fading. The fluorescence effect can be maintained for several days for retesting. 3、 The shelf life of reagents is usually within24More than a month. |
UniBestTwo insect fluorescent reagents are a specific type of immunoglobulinMPentamer, composed of5individualFITCSimultaneously labeling an antibody with a binding site exhibits significant bright fluorescence performance, and the fluorescence effect lasts for a relatively long time in the industry. |
|
Quality control standard sample |
standard configuration5Secondary usage |
Used for conducting positive control experiments to make the experimental results more accurate and reliable. |
|
|
microscopic examination system |
fluorescence microscope |
1Sampling two insects using a specialized fluorescence microscope. 2Equipped with high-end imaging equipment to achieve significant imaging effects. |
This microscopy system can effectively perform both bright and dark field microscopic observations, with good reliability and stability. |