VIP member
UTT1 General Control, Protection, and Isolation Transformer
UTT1 General Control, Protection, and Isolation Transformer
Product details
UTT1
General control, protection, and isolation transformer
Universal input voltage, PRI 208-600 Vac, SEC 2 x 115 Vac, 4000-6000 VA
General data
The maximum ambient temperature is 40 ° C
Measurement power 4000-6000 VA
Insulation material grade F
Measure input voltage 208-600 Vac
Measure output voltage 2 x 115 Vac
Protection level IP 00
Efficiency up to 96%
advantage
Fixed, shielded bolted terminal blocks that meet the requirements of UVV BGV A3
Set ± 5% tap on the input end for voltage regulation
Safe current isolation
Multiple installation sizes
Vertical specifications save space
Good corrosion resistance and minimal noise ensured through vacuum infiltration
Built in crane lifting ring
Anti slip terminal
Installation technology that has been patented
standard
Control transformers comply with VDE 0570 Part 2-2, DIN EN 61558-2-2, EN 61558-2-2, IEC 61558-2-2, UL 5085-1/-2, CSA 22.2 No.66
Isolation transformers comply with VDE 0570 Part 2-4, DIN EN 61558-2-4, EN 61558-2-4, IEC 61558-2-4, UL 5085-1/-2, CSA 22.2 No.66
Isolation transformers comply with VDE 0570 Part 2-4, DIN EN 61558-2-4, EN 61558-2-4, IEC 61558-2-4, UL 5085-1/-2, CSA 22.2 No.66
license
UL 5085-1/-2, CSA 22.2 No.66
application
As a control transformer used for electrical isolation of input and output terminals. By design, the transformer is suitable for power supply to control devices that comply with VDE 0113 requirements.
As an isolation transformer used for safe electrical isolation of input and output terminals. This transformer is suitable for the construction of protective isolation devices and protective measures that comply with VDE 0100 requirements.
480 Vac/ 500 Vac/ 525 Vac/ 550 Vac/ 575 Vac/ 600 Vac2 x 115 Vac
6000 VAUTT1-4-23
datasheet
General control, protection, and isolation transformer
Universal input voltage, PRI 208-600 Vac, SEC 2 x 115 Vac, 4000-6000 VA
General data
The maximum ambient temperature is 40 ° C
Measurement power 4000-6000 VA
Insulation material grade F
Measure input voltage 208-600 Vac
Measure output voltage 2 x 115 Vac
Protection level IP 00
Efficiency up to 96%
advantage
Fixed, shielded bolted terminal blocks that meet the requirements of UVV BGV A3
Set ± 5% tap on the input end for voltage regulation
Safe current isolation
Multiple installation sizes
Vertical specifications save space
Good corrosion resistance and minimal noise ensured through vacuum infiltration
Built in crane lifting ring
Anti slip terminal
Installation technology that has been patented
standard
Control transformers comply with VDE 0570 Part 2-2, DIN EN 61558-2-2, EN 61558-2-2, IEC 61558-2-2, UL 5085-1/-2, CSA 22.2 No.66
Isolation transformers comply with VDE 0570 Part 2-4, DIN EN 61558-2-4, EN 61558-2-4, IEC 61558-2-4, UL 5085-1/-2, CSA 22.2 No.66
Isolation transformers comply with VDE 0570 Part 2-4, DIN EN 61558-2-4, EN 61558-2-4, IEC 61558-2-4, UL 5085-1/-2, CSA 22.2 No.66
license
UL 5085-1/-2, CSA 22.2 No.66
application
As a control transformer used for electrical isolation of input and output terminals. By design, the transformer is suitable for power supply to control devices that comply with VDE 0113 requirements.
As an isolation transformer used for safe electrical isolation of input and output terminals. This transformer is suitable for the construction of protective isolation devices and protective measures that comply with VDE 0100 requirements.
| variant | Measure input voltage | Measure output voltage | measured power |
| VDE (DB cos phi=1) | UTT1-4-23 | 208 Vac/ 230 Vac/ 380 Vac/ 400 Vac/ 415 Vac/ 440 Vac/ 460 Vac/ | 480 Vac/ 500 Vac/ 525 Vac/ 550 Vac/ 575 Vac/ 600 Vac |
| 2 x 115 Vac | 4000 VA | UTT1-6-23 | 208 Vac/ 230 Vac/ 380 Vac/ 400 Vac/ 415 Vac/ 440 Vac/ 460 Vac/ |
480 Vac/ 500 Vac/ 525 Vac/ 550 Vac/ 575 Vac/ 600 Vac2 x 115 Vac
6000 VAUTT1-4-23
datasheet
Online inquiry