UFZ side mounted magnetic flap level gauge
The UFZ side mounted magnetic flap level gauge is installed on the extension pipe outside the tank, and the liquid level inside the tank can be clearl
Product details

UFZ side mounted typeMagnetic flap level gaugeInstalled on the extension pipe outside the bucket, the liquid level inside the bucket can be clearly indicated by the flap indicator. A magnetic switch can also be installed on the outside of the bypass pipe as an electrical contact signal output, or a liquid level transmitter can be installed for long-distance liquid level signal transmission and liquid level control. This level gauge is a reliable safety instrument. Due to its magnetic coupling isolation and sealed structure. Especially suitable for detecting flammable, explosive, corrosive and toxic liquid levels. Thus, the liquid level detection method in the original complex environment becomes simple, reliable, and safe. The liquid level gauge has a direct reading feature for on-site display. No need for multiple sets of liquid level gauges to be combined. It has a single unit for full range measurement. The device has advantages such as fewer openings, clear display, prominent markings, and intuitive readings. When the liquid level gauge is directly equipped with a display instrument, the intermediate transmission of the system signal detection can be eliminated to improve its transmission accuracy.
Working principle
An extension bypass pipe is installed on the outside of the bucket, and a liquid level indicator is added from the outside of the bypass pipe. A floating ball with a magnet is placed inside the bypass pipe. As the magnetic color plate contains a magnet with opposite magnetic properties to the floating ball, it will attract the magnetic color plate to flip when it rises, and the color of the magnetic color plate will change from white to red(Or silver to gold)To indicate the actual liquid level height.
Product Selection Table
Product Selection Table
|
Specification code
|
||||||||||||||||||
|
model
|
UFZ-
|
|||||||||||||||||
|
function
|
A
B
|
Liquid level (can be omitted)
interface
|
||||||||||||||||
|
Display mode
|
F
G
H
I
J
K
|
Flip board standard (can be omitted)
Flip board installation
Flip board bottom installation
Flip column standard
Flip column top
Bottom mounted flip column
|
||||||||||||||||
|
structural style
|
R
T
Z
|
Ordinary (can be omitted)
jacket
frost prevention
|
V
W
D
|
frost prevention
High temperature and high pressure
Electric heat tracing
|
||||||||||||||
|
press power
|
□
|
MPa
|
||||||||||||||||
|
Usage temperature
|
B
C
D
|
Low temperature -40 ℃ -150 ℃
Room temperature -20 ℃ -150 ℃ (can be omitted)
High temperature 0 ℃ -350 ℃
|
||||||||||||||||
|
Connecting flange
|
G
H
I
J
K
L
M
X
|
DN10(According to the same pressure standard, the flange surface is convex)
DN15(According to the same pressure standard, the flange surface is convex)
DN20(According to the same pressure standard, the flange surface is convex and can be omitted)
DN25(According to the same pressure standard, the flange surface is convex)
DN32(According to the same pressure standard, the flange surface is convex)
DN40(According to the same pressure standard, the flange surface is convex)
DN50(According to the same pressure standard, the flange surface is convex)
other
|
||||||||||||||||
|
drain valve
|
A
B
|
None (can be omitted)
have
|
||||||||||||||||
|
measuring range
|
□
|
mm
|
||||||||||||||||
|
Medium density
|
□
|
g/cm3
|
||||||||||||||||
|
material
|
P
V
F
G
H
I
L
R
S
T
X
|
PP
PVC
Stainless steel lined with PTFE
Stainless steel rolling PTFE
Stainless steel lining PP
Stainless steel lined with PVC
Fiberglass lined PP
304(Can be omitted)
321
316L
other
|
||||||||||||||||
|
Transmitter
|
1
2
|
output4~20mA(Can be omitted)
Output 0~5V
|
||||||||||||||||
|
explosion-proof
|
6
7
8
|
Ordinary type (can be omitted)
Intrinsically safe type
Explosion proof type
|
||||||||||||||||
|
Secondary table
|
A
B
C
D
E
X
|
None (can be omitted)
Single channel digital display 80 × 160
Dual channel digital display 80 × 160
Single channel digital display with light column 80 × 160
Dual channel digital display with light column 80 × 160
other
|
||||||||||||||||
|
Instrument range
|
|
(XXX)
|
Example:
|
|||||||||||||||
Ordering Notice
1. Model and specification 2, measured medium weighing and density exceeding 3, working pressure
4. Working temperature 5, measurement range 6, connecting flange (standard)
7. Supporting Instrument 8, Special Requirements
Application Notice:
1. It is recommended to install a shut-off valve between the side mounted level gauge and the upper and lower distribution pipes of the tested container to open or close the level gauge, which also facilitates maintenance of the level gauge. When the upper and lower shut-off valves are closed, the bottom drain flange of the level gauge can be opened or the drain screw can be removed, and the main body of the level gauge can be cleaned by injecting clean water.
2. Install the level gauge with a flange center perpendicularity of ∠ 4 ‰. When the measurement range of the level gauge is greater than 3 meters, it is necessary to consider adding a reinforced flange (or ear hook) in the middle as a fixed support to increase strength.
3. For the connection between the remote level gauge transmitter and the secondary instrument, it is required that the cross-sectional area of the core wire of the connection should be greater than 0.8mm2. When laid parallel to the AC power supply, a distance of at least 20 centimeters should be maintained. It is best to lay it separately in an iron pipe or with a shielded two core cable. The shielding layer can only be grounded at one end.
4. Choose a liquid level controller with contact capacity designed for resistive loads. If non resistive or high-power loads are used, intermediate relays should be used for conversion.
5. It is not advisable to use this level gauge in situations where the liquid medium contains suspended impurities and magnetic substances (as these impurities can cause blockage to the float component).
6. The "L1" in the external structure diagram is the "sinking distance" of the side mounted liquid level gauge. Users must understand this parameter, which is related to the density of the medium. According to the principle of buoyancy, the length of the float component is related to the density of the medium. Therefore, different detailed parameters of L1 must be considered for different media when selecting and designing.
Installation, use, and maintenance
1. The installation of the liquid level gauge must be vertical to ensure that the float component can move up and down freely within the main pipe.
2. It is best to install a shut-off valve between the container and the level gauge to facilitate cleaning and maintenance of the level gauge and cut off the material.
3. No magnetic conductor is allowed to approach the main tube of the liquid level gauge, otherwise it will directly affect the normal operation of the liquid level gauge.
After the installation of the liquid level gauge, it is necessary to calibrate it with magnetic steel and guide the flip column once to display red below zero position and white above zero position.
When the liquid level gauge is put into operation, the valve of the lower liquid inlet pipe should be opened first to allow the liquid medium to smoothly enter the main pipe, avoiding the liquid medium from rapidly rising with the floating ball component, which may cause column flipping failure and disorderly flipping. If this phenomenon occurs, it can be recalibrated with magnetic steel after the liquid level stabilizes.
6. In order to prevent damage to the float component during transportation, the float component is removed from the main tube of the liquid level gauge before leaving the factory. After the installation of the liquid level gauge is completed, open the bottom drain flange, and then reinstall the floating ball component into the main pipe. Note that the heavy end of the floating ball component is facing upwards and cannot be inverted.
7. According to the condition of the medium, the discharge flange can be opened regularly to clean the sediment in the main pipe.
1. Model and specification 2, measured medium weighing and density exceeding 3, working pressure
4. Working temperature 5, measurement range 6, connecting flange (standard)
7. Supporting Instrument 8, Special Requirements
Application Notice:
1. It is recommended to install a shut-off valve between the side mounted level gauge and the upper and lower distribution pipes of the tested container to open or close the level gauge, which also facilitates maintenance of the level gauge. When the upper and lower shut-off valves are closed, the bottom drain flange of the level gauge can be opened or the drain screw can be removed, and the main body of the level gauge can be cleaned by injecting clean water.
2. Install the level gauge with a flange center perpendicularity of ∠ 4 ‰. When the measurement range of the level gauge is greater than 3 meters, it is necessary to consider adding a reinforced flange (or ear hook) in the middle as a fixed support to increase strength.
3. For the connection between the remote level gauge transmitter and the secondary instrument, it is required that the cross-sectional area of the core wire of the connection should be greater than 0.8mm2. When laid parallel to the AC power supply, a distance of at least 20 centimeters should be maintained. It is best to lay it separately in an iron pipe or with a shielded two core cable. The shielding layer can only be grounded at one end.
4. Choose a liquid level controller with contact capacity designed for resistive loads. If non resistive or high-power loads are used, intermediate relays should be used for conversion.
5. It is not advisable to use this level gauge in situations where the liquid medium contains suspended impurities and magnetic substances (as these impurities can cause blockage to the float component).
6. The "L1" in the external structure diagram is the "sinking distance" of the side mounted liquid level gauge. Users must understand this parameter, which is related to the density of the medium. According to the principle of buoyancy, the length of the float component is related to the density of the medium. Therefore, different detailed parameters of L1 must be considered for different media when selecting and designing.
Installation, use, and maintenance
1. The installation of the liquid level gauge must be vertical to ensure that the float component can move up and down freely within the main pipe.
2. It is best to install a shut-off valve between the container and the level gauge to facilitate cleaning and maintenance of the level gauge and cut off the material.
3. No magnetic conductor is allowed to approach the main tube of the liquid level gauge, otherwise it will directly affect the normal operation of the liquid level gauge.
After the installation of the liquid level gauge, it is necessary to calibrate it with magnetic steel and guide the flip column once to display red below zero position and white above zero position.
When the liquid level gauge is put into operation, the valve of the lower liquid inlet pipe should be opened first to allow the liquid medium to smoothly enter the main pipe, avoiding the liquid medium from rapidly rising with the floating ball component, which may cause column flipping failure and disorderly flipping. If this phenomenon occurs, it can be recalibrated with magnetic steel after the liquid level stabilizes.
6. In order to prevent damage to the float component during transportation, the float component is removed from the main tube of the liquid level gauge before leaving the factory. After the installation of the liquid level gauge is completed, open the bottom drain flange, and then reinstall the floating ball component into the main pipe. Note that the heavy end of the floating ball component is facing upwards and cannot be inverted.
7. According to the condition of the medium, the discharge flange can be opened regularly to clean the sediment in the main pipe.
Characteristics and applicable locations
1Suitable for high temperature, high pressure, strong acid, strong alkali and explosion-proof requirements, the structure is simple, reliable and durable, and can be equipped with various optional accessories to make control easier.
2Install a liquid level transmitter and magnetic switch, which can be installed or adjusted at any time without stopping the machine.
3If the power supply is interrupted, the on-site magnetic switch is not affected and has high accuracy.
4, every10Add a color swatch of different colors in centimeters to make the liquid level easy to identify.
5Suitable for dyeing and finishing equipment, wastewater treatment, power plants, chemical equipment, hot kerosene boilers, and petrochemical industries.