Shanghai Linpin Instrument Co., Ltd
Home>Products>Thermal laboratory
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    13636505737
  • Address
    No. 888, Zhangong Road, Linhai Industrial Zone, Fengxian District, Shanghai
Contact Now
Thermal laboratory
Product use: Thermal testing laboratory is an essential testing equipment in aviation, automotive, home appliances, scientific research and other fiel
Product details
Equipment model Studio size (D * W * H) mm Dimensions (D * W * H) mm
LRHS-101B-LS 450×450×500 1160×1000×1610
LRHS-225B-LS 500×600×750 1210×1150×1870
LRHS-504B-LS 700×800×900 1260×1340×2070
LRHS-800B-LS 800×1000×1000 1370×1550×2170
LRHS-1000B-LS 1000×1000×1000 1560×1550×2170
sexually
ability
finger
treetop
temperature range A:-20℃~150℃ B:-40℃~150℃
C:-60℃~150℃ D:-70℃~150℃
temperature uniformity ≤ 2 ℃ (when unloaded)
temperature fluctuation ± 0.5 ℃ (when unloaded)
Time setting range 1~9999H
Humidity range 20%~98% RH
humidity uniformity +2% -3% RH
Humidity fluctuation ±2%
heating rate 1.0~3.0℃/min
cooling rate 0.7~1.0℃/min
test hole Installed on the left side of the machine, used for external testing of power or signal lines
Observation window 210 × 275mm or 395 × 395mm (effective field of view)
send
use
material
material
External material High quality A3 steel plate electrostatic spraying
Inner box material Imported high-grade stainless steel SUS304
Insulation material Rigid polyurethane foam+glass fiber
pit
the heart
join in marriage
place
temperature controller Korean ternary TEMI300
temperature sensor PT100 platinum resistance thermometer
Cooling method Single machine or double machine cascade refrigeration
compressor Taikang, France
Standard configuration 1 roll of wet ball gauze, 2 layers of sample rack, equipped with a condensate water collection tray, and discharged outside the box
Safety protection Compressor overpressure overload, fan motor overheating, whole machine under phase/reverse phase
Overtemperature, overall equipment timing, leakage protection, overload and short circuit protection
supply voltage AC380V±10% 50Hz
Power (A)3.5kW/4.0kW/6.0kW/8.0kW/9.0kW
(B)4.0kW/4.5kW/7.5kW/9.0kW/10.5kW
(C)4.5kW/6.5kW/9.0kW/13.0kW/13.0kW
Usage environment 5℃~+28℃ ≤85% RH
Note:
1. The above data were measured under good ventilation conditions at an ambient temperature of 25 ℃
2. Customized high and low temperature wet heat test rooms can be customized according to specific testing requirements of users
3. This technical information is subject to change without prior notice

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!