Changsha Aikesipu Instrument Equipment Co., Ltd
Home>Products>Tektronix DPO3012DPO3K digital fluorescence oscilloscope from the United States
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
  • Address
    611 Xiangyu Smart South Building, Kaifu District, Changsha City, Hunan Province
Contact Now
Tektronix DPO3012DPO3K digital fluorescence oscilloscope from the United States
Introduction: Digital Fluorescence Oscilloscope Introduction: ● Multi functional mixed signal design and debugging tool ● Provides outstanding process
Product details

Introduction to Digital Fluorescence Oscilloscope:
● Multi functional mixed signal design and debugging tool
Provide outstanding processing capabilities for quickly solving problems - DPO3000 series digital fluorescence oscilloscopes (DPOs) provide the performance you need to view the most demanding signals. The bandwidth range of the digital fluorescence oscilloscope is 100 MHz -500 MHz. All models of the digital fluorescence oscilloscope provide a minimum oversampling rate of 5 times on all channels and come standard with sin (x)/x interpolation, so you can build confidence and accurately capture and display the fastest transient events. All channels of the digital fluorescence oscilloscope are equipped with a recording length of 5M. The digital fluorescence oscilloscope can capture long signal activity windows while ensuring fine timing resolution. The waveform capture rate of 50000 wfm/s maximizes the probability of capturing difficult to detect spikes and other incidental events.

Technical specifications of digital fluorescence oscilloscope:
Main performance indicators of digital fluorescence oscilloscope
● 500, 300, 100 MHz bandwidth models
● 2-channel and 4-channel models
A sampling rate of up to 2.5 GS/s on all channels
Record length of 5 M points on all channels
Maximum waveform capture rate of 50000 wfm/s
● Complete set of advanced triggers
Serial bus triggering and decoding
I2C, SPI, CAN, LIN, RS232/422/485/UART serial triggering, decoding, and analysis options
Easy to use features
● Wave Inspector? The control function provides unprecedented waveform analysis efficiency
9-inch (229 mm) WVGA widescreen color display
● USB 2.0 interface on the front panel for quick and easy storage of data
USB 2.0 device port, use USB TMC to directly control oscilloscope through PC
● Built in Ethernet port
Plug and play connectivity and analysis software solution
● e*Scope? Remote viewing and control
● TekVPI? The probe interface supports active probes, differential probes, and current probes, with automatic calibration and unit determination
● Small size and light weight
Only 5.4 inches (137mm) deep, weighing only 9 pounds (4 kilograms)

Application scope of digital fluorescence oscilloscope:
Embedded design and debugging, investigation of transient phenomena, power measurement, video design and debugging, spectrum analysis, automotive electronics design and debugging, manufacturing testing and quality control, electromechanical design and analysis, biomedical product development, industrial control
1. Zoom/Scroll - A dedicated front panel control function for zooming and scrolling. The internal knob controls the scaling factor, while the outer ring adjustment scrolls the scaling box in the waveform. Waveform search has become unprecedentedly simple.
2 Marking - Do you want to mark waveforms for future reference or quickly navigate between events of interest? Just press the Set Mark button and place the 'bookmarks' on the waveform. Use the ← and → buttons to navigate through user tags and search for generated tags.
Tired of endlessly rotating the horizontal position knob on the current oscilloscope to find the event you are looking for? You can use the powerful search function of DPO3000 to find and tag all events that occur based on user specified criteria. The search types include edge, pulse width, short pulse, logic, setup time and hold time, rise/fall time, and I2C, SPI, CAN, LIN, and RS-232/422/485/UART packet components.
4 Serial Bus - Trigger packet level content, view data collected as a bus, decode all data packets into hexadecimal or binary, search for collected data, find specific packet components, and even view all decoded data packets in tabular form, which is largely similar to what is seen on a logic analyzer. The supported serial standard data includes I2C, SPI, CAN, LIN, and RS-232/422/485/UART packet contents
5 Excellent Monitors - The DPO3000 series features a 9-inch (229mm) widescreen high-resolution (800x480-WVGA) monitor.
6 USB - Use the front panel USB port to easily and conveniently store screen snapshots, waveform data, and oscilloscope settings. The back panel provides another USB host port for connecting peripherals, as well as a USB device port for controlling instruments using USBTMC.
7 Vertical Control Function - The vertical control function of each channel knob provides simple and intuitive operation capabilities. You no longer need to share a set of vertical control functions in all four channels!
8 TekVPI? The new TekVPI probe interface can directly connect to the current probe, intuitively control the compensation frame, remotely control probe settings, and communicate more intelligently between the oscilloscope and the probe.
Vertical system DPO3012 DPO3014 DPO3032 DPO3034 DPO3052 DPO3054
Number of input channels 2 4 2 4 2 4
Analog bandwidth (-3dB) 100 MHz 100 MHz 300 MHz 300 MHz 500 MHz 500 MHz
Calculated rise time
5 mV/div (typical value) 3.5 ns 3.5 ns 1.17 ns 1.17 ns 700 ps 700 ps
Hardware bandwidth limit of 20 MHz or 150 MHz
Input coupling AC, DC, GND
Input impedance 1 M Ω± 1%, 75 Ω± 1%, 50 Ω± 1%
Input sensitivity range
1 MΩ 1 mV/div - 10 V/div
Input sensitivity range
75Ω, 50Ω 1 mV/div - 1 V/div
Vertical resolution of 8 bits (11 bits when using Hi Res)
Maximum input voltage, 1 M Ω 300 VRMS, peak value ≤ ± 450 V
Maximum input voltage
75 Ω, 50 Ω 5 VRMS, peak value ≤± 20 V
DC gain accuracy ± 1.5%, bias set to 0 V
Bias range 1 M Ω 50 Ω, 75 Ω
1 mV/div - 99.5 mV/div ± 1 V ± 1 V
100 mV/div - 995 mV/div ± 10 V ± 5 V
1 V/div ± 100 V ± 5 V
1.01 V/div - 10 V/div ± 100 V NA

Channel to channel isolation:
(Any two channels with equal vertical scales) ≥ 100:1 at ≤ 100 MHz, ≥ 30:1 at>100 MHz to rated bandwidth