Xiamen Tianyan Instrument Co., Ltd
Home>Products>TYTC-2001 Coating Thickness Gauge
TYTC-2001 Coating Thickness Gauge
Large measurement range 0-5000 μ m. Corresponding probes can be selected based on the tested material: measuring the thickness of non-magnetic coating
Product details

The TYTC-2001 coating thickness gauge is the crystallization of high-tech. It adopts single-chip technology, with high accuracy, digital display, stable indication, low power consumption, simple and convenient operation, touch buttons, single probe full range measurement, small size, and light weight; And it has storage, reading, statistics, low voltage indication, system/midnight/Two point calibration, its performance reaches the advanced level of contemporary international similar instruments.

This instrument uses electromagnetic induction method to measure the thickness of the coating (plating) layer. The probe located on the surface of the component generates a closed magnetic circuit, which will change to varying degrees as the distance between the probe and the ferromagnetic material changes, causing changes in magnetic resistance and probe coil inductance. This principle can be used to accurately measure the distance between the probe and the ferromagnetic material, that is, the thickness of the coating (plating) layer.

This instrument adopts magnetic thickness measurement method, which can conveniently and non destructively measure the thickness of non-magnetic coatings on ferromagnetic materials, such as zinc, copper, chromium coatings on steel surfaces or coatings of paint, enamel, fiberglass, spray coating, asphalt, etc. This instrument is widely used in industries such as machinery, automotive, shipbuilding, petroleum, chemical, electroplating, spraying, enamel, plastics, etc.

IIProduct features:

1. Measurement: Full range thickness measurement with a single probe;

2. Storage and deletion: can store measurement data600A single suspicious item in the measurementData can be deleted, and all data in the storage area can also be deleted;

3. Read: Read the stored measurement data;

4. Statistics: There are three statistical measures, with the maximum and minimum average values;

5. Calibration: System calibration can be performed;

6. Electricity level: equipped with undervoltage display function;

7. Printing: capable of printing measurement values, optional micro printer;

8. Shutdown: There are two methods: automatic shutdown and manual shutdown.



Tags:& Nbsp coating thickness gauge

Technical parameters:

1Measurement range: TYTC-2001(0—5000μm),TYTC-200310—9000μm);

2. Measurement error:< 3%±1μm;

3. Minimum indication:1μm;
4. Display mode:4LCD digital display;

5. Power supply: two sections“AAA”Battery;

6. Power consumption: maximum power consumption100mw

7. External dimensions:124*50*24mm);

8. Weight:150g(including battery).



Tags:& Nbsp coating thickness gauge

This instrument adopts the magnetic thickness measurement method, which can conveniently and non destructively measure the thickness of non-magnetic material coatings on ferromagnetic materials, such as zinc, copper, chromium coatings on steel surfaces or coatings of paint, enamel, fiberglass, spray coating, asphalt, etc. This instrument is widely used in industries such as machinery, automobiles, shipbuilding, petroleum, chemical, electroplating, spraying, enamel, plastics, etc


Tags:& Nbsp coating thickness gauge

Technical Support 1: 0592-3195306 /
Contact: Manager Lian


Technical Support 2: 0592-3195308 /

Contact: Manager Peng



Tags:& Nbsp coating thickness gauge
Product Selection Guide-clickDownload: Xiamen Tianyan Instrument Coating Thickness Gauge Selection Guide
Comparison of Main Parameters for Coating Thickness Measurement by Xiamen Tianyan Instrument

project

model

Measurement range (mm)

maximum

resolution

Application scenarios

STATISTICS

TYTC

0-1250μm

0.1μm

It can measure the thickness of non-magnetic coatings on magnetic metal substrates, as well as the thickness of non-conductive coatings on non-magnetic metal substrates, making it a dual-use device

Average value(MEAN), maximum value(MAX)Minimum value(MIN)Test frequency(NO.), standard deviation(SDEV

TYTC-2001

0-5000μm

1μm

Optional according to the tested material: measure the thickness of non-magnetic coatings on ferromagnetic materials, or measure non-conductive coatings on non-magnetic metal substrates

Average value(MEAN), maximum value(MAX)Minimum value(MIN

TYTC-2003

10-9000μm

1μm

Optional according to the tested material: measure the thickness of non-magnetic coatings on ferromagnetic materials, or measure non-conductive coatings on non-magnetic metal substrates

Average value(MEAN), maximum value(MAX)Minimum value(MIN

Application scenario explanation:

TYTCTwo thickness measurement methods, magnetic and eddy current, are used. By replacing the corresponding probe, the thickness of the non-magnetic coating layer on the magnetic metal substrate can be measured, and the thickness of the non-conductive coating layer on the non-magnetic metal substrate can also be measured, with a wider range of applications.

TYTC-2001/2003It is also possible to measure the thickness of non-magnetic coatings on ferromagnetic materials or non-conductive coatings on non-magnetic metal substrates through optional configurations. Only one can be chosen, and the optional configuration cannot be changed after leaving the factory. Different items need to be tested later and instruments need to be purchased again.



Tags:& Nbsp coating thickness gauge
Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!