VIP member
TT1 Control, Protection, and Isolation Transformer
TT1 Control, Protection, and Isolation Transformer
Product details
TT1
Control, protection, and isolation transformers
Supporting angle iron, PRI 230/400 Vac, SEC 24, 42, 2 x 115 Vac, 1.000-25.000 VA
General data
Effectiveness up to 98%
Measure power 1.000-25.000 VA
The maximum ambient temperature is 40 ° C
Insulation material grade F
Measure output voltage 24, 42, 2 x 115 Vac
Measure input voltage 219 Vac -525 Vac
Optional matching body suitable for high protection level
Protection level IP 00
advantage
Fixed, shielded bolted terminal blocks that meet the requirements of UVV BGV A3
Set ± 5% tap on the input end for voltage regulation
Safe current isolation
Installation technology that has been patented
Multiple installation sizes
Good corrosion resistance and minimal noise ensured through vacuum infiltration
Vertical specifications save space
Built in crane lifting ring
Anti slip terminal
standard
Control transformers comply with VDE 0570 Part 2-2, DIN EN 61558-2-2, EN 61558-2-2, IEC 61558-2-2, UL 5085-1/-2, CSA 22.2 No.66
Isolation transformers comply with VDE 0570 Part 2-4, DIN EN 61558-2-4, EN 61558-2-4, IEC 61558-2-4, UL 5085-1/-2, CSA 22.2 No.66
The protection transformer complies with VDE 0570 Part 2-6, DIN EN 61558-2-6, EN 61558-2-6, IEC 61558-2-6, UL 5085-1/-2, CSA 22.2 No.66
license
UL 5085, CSA 22.2 (E 103521)
application
As a protective transformer used for safe electrical isolation of input and output terminals. By limiting the output voltage, this transformer is suitable for circuit construction of SELV and PELV.
Isolation transformer used for safe electrical isolation of input and output terminals. This transformer is suitable for the construction of protective isolation devices and protective measures that comply with VDE 0100 requirements.
As a control transformer used for electrical isolation of input and output terminals
25.000 VA
TT1 datasheet
Control, protection, and isolation transformers
Supporting angle iron, PRI 230/400 Vac, SEC 24, 42, 2 x 115 Vac, 1.000-25.000 VA
General data
Effectiveness up to 98%
Measure power 1.000-25.000 VA
The maximum ambient temperature is 40 ° C
Insulation material grade F
Measure output voltage 24, 42, 2 x 115 Vac
Measure input voltage 219 Vac -525 Vac
Optional matching body suitable for high protection level
Protection level IP 00
advantage
Fixed, shielded bolted terminal blocks that meet the requirements of UVV BGV A3
Set ± 5% tap on the input end for voltage regulation
Safe current isolation
Installation technology that has been patented
Multiple installation sizes
Good corrosion resistance and minimal noise ensured through vacuum infiltration
Vertical specifications save space
Built in crane lifting ring
Anti slip terminal
standard
Control transformers comply with VDE 0570 Part 2-2, DIN EN 61558-2-2, EN 61558-2-2, IEC 61558-2-2, UL 5085-1/-2, CSA 22.2 No.66
Isolation transformers comply with VDE 0570 Part 2-4, DIN EN 61558-2-4, EN 61558-2-4, IEC 61558-2-4, UL 5085-1/-2, CSA 22.2 No.66
The protection transformer complies with VDE 0570 Part 2-6, DIN EN 61558-2-6, EN 61558-2-6, IEC 61558-2-6, UL 5085-1/-2, CSA 22.2 No.66
license
UL 5085, CSA 22.2 (E 103521)
application
As a protective transformer used for safe electrical isolation of input and output terminals. By limiting the output voltage, this transformer is suitable for circuit construction of SELV and PELV.
Isolation transformer used for safe electrical isolation of input and output terminals. This transformer is suitable for the construction of protective isolation devices and protective measures that comply with VDE 0100 requirements.
As a control transformer used for electrical isolation of input and output terminals
| variant | Measure input voltage | Measure output voltage | measured power |
| VDE (DB cos phi=1) | TT1 1-4-23 | 380/400/420 Vac | 2 x 115 Vac |
| 1.000 VA | TT1 1-23-24 | 219/230/241 Vac | 24 Vac |
| 1.000 VA | TT1 1,6-4-23 | 380/400/420 Vac | 2 x 115 Vac |
| 1.600 VA | TT1 1,6-4-42 | 380/400/420 Vac | 42 Vac |
| 1.600 VA | TT1 1,6-23-24 | 219/230/241 Vac | 24 Vac |
| 1.600 VA | TT1 2-4-23 | 380/400/420 Vac | 2 x 115 Vac |
| 2.000 VA | TT1 2-23-24 | 219/230/241 Vac | 24 Vac |
| 2.000 VA | TT1 2,5-4-23 | 380/400/420 Vac | 2 x 115 Vac |
| 2.500 VA | TT1 2,5-4-42 | 380/400/420 Vac | 42 Vac |
| 2.500 VA | TT1 2,5-23-24 | 219/230/241 Vac | 24 Vac |
| 2.500 VA | TT1 3-4-23 | 380/400/420 Vac | 2 x 115 Vac |
| 3.000 VA | TT1 3-5-23 | 475/500/525 Vac | 2 x 115 Vac |
| 3.000 VA | TT1 3-44-23 | 418/440/462 Vac | 2 x 115 Vac |
| 3.000 VA | TT1 4-4-23 | 380/400/420 Vac | 2 x 115 Vac |
| 4.000 VA | TT1 4-5-23 | 475/500/525 Vac | 2 x 115 Vac |
| 4.000 VA | TT1 4-44-23 | 418/440/462 Vac | 2 x 115 Vac |
| 4.000 VA | TT1 5-4-23 | 380/400/420 Vac | 2 x 115 Vac |
| 5.000 VA | TT1 5-5-23 | 475/500/525 Vac | 2 x 115 Vac |
| 5.000 VA | TT1 5-44-23 | 418/440/462 Vac | 2 x 115 Vac |
| 5.000 VA | TT1 6,3-4-23 | 380/400/420 Vac | 2 x 115 Vac |
| 6.300 VA | TT1 6,3-5-23 | 475/500/525 Vac | 2 x 115 Vac |
| 6.300 VA | TT1 6,3-44-23 | 418/440/462 Vac | 2 x 115 Vac |
| 6.300 VA | TT1 8-4-23 | 380/400/420 Vac | 2 x 115 Vac |
| 8.000 VA | TT1 8-5-23 | 475/500/525 Vac | 2 x 115 Vac |
| 8.000 VA | TT1 8-44-23 | 418/440/462 Vac | 2 x 115 Vac |
| 8.000 VA | TT1 10-4-23 | 380/400/420 Vac | 2 x 115 Vac |
| 10.000 VA | TT1 10-5-23 | 475/500/525 Vac | 2 x 115 Vac |
| 10.000 VA | TT1 10-44-23 | 418/440/462 Vac | 2 x 115 Vac |
| 10.000 VA | TT1 12,5-4-23 | 380/400/420 Vac | 2 x 115 Vac |
| 12.500 VA | TT1 15-4-23 | 380/400/420 Vac | 2 x 115 Vac |
| 15.000 VA | TT1 20-4-23 | 380/400/420 Vac | 2 x 115 Vac |
| 20.000 VA | TT1 25-4-23 | 380/400/420 Vac | 2 x 115 Vac |
25.000 VA
TT1 datasheet
Online inquiry