TSI Respirator Suitability/Fit Tester (TSI8048)Product Introduction


PortaCountThe suitability tester is a testing instrument that provides a consistent and objective testing experience, suitable for includingN95Filter masks and various types of respirators, and the instrument also hasFitCheckNew features such as mode and suitability testing animation tutorials help users better and faster verify the suitability of respirators.
FitCheckThe mode displays real-time changes in the suitability of the respirator throughout the entire wearing and adjustment process, helping users select the appropriate respirator and achieve optimal suitability faster.
Animated tutorial videos can guide employees to correctly perform each inspection training, provide a consistent inspection experience, and reduce personnel costs.
PortaCountIt is a reliable suitability testing instrument that improves employee safety and production efficiency for you.
TSI Respirator Suitability/Fit Tester (TSI8048)Product Features:
comply withOSHATheCSATheHSEandANSIStandard, applicable to all confidential information
Respirators, including:95、99、100TheFFP1TheFFP2andFFP3Filter type respirator
The suitability factor for measurement can be greater than10,000
Using tiny particles in ambient air to calculate the suitability factor of respirators
useFitPro UltraSoftware automatically performs suitability testing
real-timeFitCheckThe mode can train new users and exclude those who have failedSexual testing
The mask sampling adapter kit can be used for suitability testing on employees' personal respirators
Through software, it can be found on the suitability test report orIDPrint suitability test card on the card
Technical Specifications:
Suitable factor range:1~10,000AboveN95The face mask is1~200
Typical suitability factor accuracy:Reading of±10%
Respiratory mask for suitability testing
Elastic full face cover
Elastic half face mask
NIOSH 100Series filter mask
NIOSH 99Series filter mask
NIOSH 95Series filter mask
FFP1TheFFP2TheFFP3Series of respirators
Suitable factor measurement: directly measure the suitable factor(Cout/Cin)*
Size:12 cm x 27 cm x 24 cm(4.83 in. x 10.5 in. x 9.46 in.)
Weight: Single device3.2 kg(7.0 lb.)Including standard accessories and instrument boxes6.9 kg(15.35 lb.)
power supply100 ~ 250VAC,50-60Hz
Traffic: Sampling traffic350 cm3/min, total traffic1000 cm3/min(nominal value)
Temperature Range Operating Temperature0 ~ 38°C(32 ~ 100°F)
Storage temperature-40 ~ 50°C(-40 ~ 122°F)
Working fluid:99.5%Reagent grade isopropanol
Running time after fully charged At21°C(70°F)At temperature, it is 6 hour
Instrument box: size(HWD)25.4 cm x 52.1 cm x 39.4 cm
(10.0 in. x 20.5 in. x 15.5 in.)pass/Failed to set up User defined:0 ~ 10,000
Factory calibration interval: one year