| TMES 1、 2 Endoscope TMES Series |
| |
| |
 |
|
The SKF TMES series endoscope provides a low-cost and efficient method for equipment maintenance engineers to visually inspect inaccessible equipment. Without disassembling the machine, it is possible to visually inspect areas that are not visible, such as the interior of the chassis due to low light, lack of light, or obstructed by objects. Its typical applications include gearboxes, gears, compressors, crankcases, fan blades, etc.
SKF offers two types of endoscopes for customers to choose from: TMES 1 and TMES 2.These two endoscopes are equipped with different light sources and fibers of varying lengths to meet the needs of different industrial applications.
|
|
|
| Technical Specifications |
Order Number |
TMES 1 |
TMES 2 |
description |
Industrial endoscope, basic type |
Industrial endoscope, enhanced type |
optical fiber |
|
|
Fiber optic materials |
Acrylic acid fiber |
Acrylic acid fiber |
pixel |
3,500 |
7,400 |
Fiber optic standard diameter |
35mm
|
13mm
|
Allow fiber breakage rate |
*Big2%
|
*Big0.5%
|
optical cable |
|
|
Fiber optic materials |
SUS304beltPVCPlastic skin
|
SUS304beltPVCPlastic skin
|
*Small bending radius |
40mm |
40mm |
Cable length |
1m |
3m |
Cable diameter |
8mm |
5mm |
light source |
|
|
Luminous power |
3.5V, 0.7A, 2.55W
|
3.5V, 0.7A, 2.55W |
power supply |
3sectionC(LR 14)battery
|
3sectionC(LR 14)battery
|
optical parameters |
|
|
visual direction |
Direct gaze |
Direct gaze |
field of view |
60o |
55o |
focal length |
10mm(Fixed)
|
10mm(Fixed)
|
waterproof performance |
Objective lens and optical cable1-1.3BarWaterproof under air pressure, the eyepiece part is not waterproof
|
Objective lens and optical cable1-1.3BarWaterproof under air pressure, the eyepiece part is not waterproof
|
Working temperature range |
-20oC—60oC
|
-20oC—60oC
|
Total weight |
1,135g |
1,135g
|
Package dimensions |
360 x 270 x 80mm |
360 x 270 x 80mm |
|
Characteristics of TMES endoscope |
Compact and portable
High quality optical components ensure high image clarity for equipment diagnosis
Small diameter long optical fibers can enter various confined spaces
Bending radius up to40mmThe freely bendable optical fiber
Fiber optic waterproof, suitable for humid environments
Built in battery provides power for the light source, with adjustable brightness
Adjustable handle length
View the image directly on the camera without spending time adjusting it
Large field of view
Easy to assemble and use, no special training required
Can be used in conjunction with a digital camera (requires a camera holder) to capture images, make reports, or send images for equipment diagnosis
|
|
| Order Information |
| Item Number |
description |
| TMES 1 |
TMES Type 1 endoscope, including handle, eyepiece, fiber optic, and instrument box |
| TMES 1/KIT1 |
TMES 1 endoscope, including TMES 1, 90 degree angle eyepiece, and digital camera holder |
| TMES 2 |
TMES 2 endoscope, including handle, eyepiece, fiber optic, and instrument box |
| TMES 2/KIT1 |
MES 2 endoscope, including TMES 2, 90 degree angle eyepiece, and digital camera holder |
| |
|
| Accessories and spare parts |
| TMES 1-M |
90 degree angle eyepiece, used for TMES 1 |
| TMES 1-L |
Lighting bulb, for TMES 1 and TMES 2 |
| TMES 1-C |
Digital camera holder for TMES 1 and TMES 2 |
| TMES 2-M |
90 degree angle eyepiece, used for TMES 2 |
| |
|
|
 |
|