TEROS 12 Soil Moisture, Temperature, and Conductivity SensorIt's original5TE、Upgraded version of GS3,TEROS12 soil moisture, temperature, and conductivity sensors combine accuracy, economy, ease of use, and reliability. The TEROS 12 sensor can be connected to METER's latest data acquisition, such as ZL6, enabling plug and play of sensors and cloud storage management of data.
main features
Simultaneously measuring soil volumetric moisture content(EWC)、 Conductivity and temperature
The latest rapid conductivity measurement method
Thermistor embedded with intermediate probe
Total moisture measurement range——Sensitive sensing of subtle changes in moisture content within the range of 0~100% VWC
The frequency of use is70MHz capacitor technology minimizes the impact of salt and texture as much as possible
Special stainless steel probe for easy insertion into various soils and good contact
Epoxy resin filling ensures field burialover 10 years
Suitable for various data acquisition, and the voltage output is easy to read

TECHNICAL INDEX
Measurement indicators
Volume Moisture Content (VWC)
Apparent dielectric constant ε a
temperature
conductivity
range
Mineral soil calibration: 0.00~0.62 m3/m3
Non soil medium calibration: 0.0~1.0 m3/m3
1 (air)~80 (water)
-40~60℃
0 - 10 dS/m
resolution
0.001 m3/m3
0.1℃
0.001 dS/m
accuracy
Typical mineral soil universal calibration: ± 0.03 m3/m3 In (± 3.00% VWC),
Special calibration in any porous medium: ± 0.01-0.02 m3/m3 (± 1-2% VWC).
±1εa @1-40 (soil range);
±1℃
±5%
sensor type
Frequency domain principle
——
——
When the conductivity of soil solution is less than 8 dS/m;
15% of the measured value @ 40~80
Size:9.4 cm x 2.4 cm x 7.5 cm Support data collection (purchased separately):METER's ZL6, EM50/60 series); Other data acquisition systems that provide 4.0~15VDC power supply and support serial communication or SDI-12 communication
Probe length:5.5 cm
Work environment:-40~60 ℃ (sensors available for use in higher or lower environments, please contact us if needed)
Cable length:standard5m. Other lengths can be customized, up to a maximum of 75m.
Type of connector:3.5mm headphone plug or bare wire connector
Measurement volume:1010 cm³
Measurement time:25-150 ms (milliseconds)
Supply Voltage(VCC) to GND:minimum4.0 VDC; Typical: NA; maximum 15.0 VDC
Digital input voltage(High logic): Minimum:2.8V; Typical 3.6V; Maximum: 3.9V
Digital input voltage(Low logic): Minimum:-0.3V; Typical 0.0V; Maximum: 0.8V
Digital input voltage(High logic):minimum:NA; Typical: 3.6V; Maximum: NA
Power line conversion rate: Minimum1.0V/ms; Typical: NA; Maximum: NA
electric current:25 second measurement period: minimum 3.0mA; typical 3.6mA; maximum 16.0mA; static waiting period: minimum NA; typical 0.03mA; maximum NA
Start Time:DDI serial port: minimum 80ms; typical NA; maximum 100ms; SDI-12: minimum NA; typical 245ms; maximum NA
Following standards:exist Production under ISO 9001:2015 standard; EM ISO/IEC 17050:2010 (CE marking); 2014/30/EU and 2011/65/EU; EN61326-1:2013 and EN55022/CISPR 22
electric current:25 second measurement period: 3.0~16.0mA, typical 3.6mA; static waiting period: typical 0.03mA
Start Time:DDI serial port 80-100ms; SDI-12 typical 245ms
Origin and Manufacturer: United StatesMETER Corporation (Former Decagon)