TC-120F(GZ)Type air heavy metal sampler
Product Introduction
TC-120F(GZ)The air heavy metal sampler is suitable for collecting heavy metal particles in the atmosphere(TSP)。 This instrument adopts high-tech in the fields of sensors, new materials, etc., with reliable quality, stable performance, and long service life. Suitable for routine monitoring and environmental evaluation of the atmosphere by relevant departments such as factories, mines, environmental protection, labor, health, scientific research, meteorology, etc.
Adopting standards
HJ/T 374-2007 Technical Requirements and Testing Methods for Total Suspended Particle Samplers
JJG 943-2011 "Total Suspended Particle Sampler"
HJ 618-2011 "Determination of PM10 and PM2.5 in ambient air by gravimetric method"
HJ/T 93-2013 "Technical Requirements and Detection Methods for Particulate Matter (PM10 and PM2.5) Samplers in Environmental Air"
Q/0213TWB 001-2014 Enterprise Standard
main features
1. Brushless high negative pressure sampling pump,At a flow rate of 100L/min, it can overcome a resistance of 20kPa;
2. Electronic flowmeter, constant current sampling;
3. Equipped with a real-time clock, it can be set for timed sampling with multiple sampling intervals;
4. The TSP/PM10/PM2.5 sampling head is made of aluminum alloy material and has anti-static adsorption;
5. Automatic measurement of temperature and air pressure, automatic calculation of standard sampling volume;
6. Small size, light weight, easy to carry;
7. Large sized Chinese dot matrix LCD screen with automatic contrast adjustment, capable of operating below zeroNormal operation at 30 degrees Celsius;
8. Power off protection function, automatic sampling of incoming calls;
9. Sampling data can be printed orUSB drive export;
TECHNICAL INDEX
|
Parameters |
Parameter range |
resolution |
accuracy |
|
sample flow |
(60~130)L/min |
0.1L/min |
Better than ± 2.5% |
|
Traffic stability |
|
Better than ± 2.0% |
|
|
Traffic repeatability |
|
Better than ± 2.0% |
|
|
sample time |
1min~99h59min |
1min |
Not exceeding ± 0.2% |
|
Pre measurement pressure |
(-20~0)kPa |
0.01kPa |
Better than ± 2.5% |
|
Environmental atmospheric pressure |
(70~130)kPa |
0.01kPa |
Better than ± 2.5% |
|
Timed startup |
24-hour clock system |
||
|
Equidistant sampling time |
Set freely within 99 hours and 59 minutes |
||
|
Equal interval sampling frequency |
1 to 99 times |
||
|
noise |
<59dB(A) |
||
|
Overall dimensions (W × D × H) mm |
260×280×350 |
||
|
weight |
About 8.0 kg |
||
|
power supply |
AC220V±10% 50HZ |
||
|
power consumption |
<600W |
||
|
Sampling head indicators |
|||
|
PM2.5 cutting characteristics |
Da50=(2.5 ± 0.2) μ m 〥 g=(1.2 ± 0.1) μ m |
||
|
PM10 cutting characteristics |
Da50=(10 ± 0.5) μ m 〥 g=(1.5 ± 0.1) μ m |
||
|
inlet velocity |
0.3m/s |
||
|
b/a |
0.625 |
||
|
sample flow |
100L/min |
||
|
Effective filter membrane diameter |
Ф80mm |
||
|
Connector |
M20×1.5 |
||
TC-120F(GZ)Type air heavy metal sampler
dress box one
|
Serial Number |
name |
unit |
quantity |
notes |
|
1 |
host |
tower |
1 |
|
|
2 |
Main aluminum box |
individual |
1 |
|
|
3 |
Attachment aluminum box |
individual |
1 |
|
|
4 |
TSP/PM10sampling |
individual |
1 |
|
|
5 |
Fluoride sampling head (optional) |
individual |
1 |
|
|
6 |
power line |
root |
1 |
|
|
7 |
Tripod |
individual |
1 |
|
|
8 |
Sampling filter membrane |
box |
1 |
glass fiber filters |
|
9 |
Sampling filter membrane |
box |
1 |
Polytetrafluoroethylene filter membrane |
|
10 |
Filter membrane clamp box |
individual |
2 |
|
|
11 |
Product manual |
share |
1 |
|
|
12 |
Product Qualification Certificate |
share |
1 |
|
|
13 |
Warranty Card |
share |
1 |
|