Guangzhou Wanhao Optoelectronic Technology Co., Ltd
Home>Products>T series microscope live cell incubator
Product Groups
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    14715029953/(00852)94524898
  • Address
Contact Now
T series microscope live cell incubator
The modular DMi8 inverted microscope is the core of the DMi8 S platform, providing a complete solution for live cell imaging research.
Product details

Product Overview:

The product configuration is flexible and can be applied to various brands of inverted microscopes, upright microscopes, and stereomicroscopes. The LCI live cell imaging system has a wide range of applications, including cell migration and cytoskeleton, cell division and cell cycle, cell signal transduction, tissue differentiation and development, protein localization, pharmacological and toxicological studies, vesicle and protein transport, calcium ion signaling studies, and protein DNA interactions.

Desktop live cell culture system:

Automatic induction mode magnetic components user-friendly control touch screen panel compact system.The live cell culture system T is a simple and integrated system that maintains all basic parameters in a physiological state, ensuring optimal experimental conditions for cell survival under a microscope, and achieving the goal of "good cells, successful research".

Provide precise control conditions, including optimized temperature, humidity CO2And optional O2Concentration is very suitable for long-term live cell imaging in various magnetic imaging chambers. The temperature and gas concentration of the main body, incubator cover, humidifier, and lens heater are controllable and can be recorded. The gas gradient can be programmed through CCP (Computer Control Program) software.

Performance:

Three types of automatic induction mode temperature control with heating feedback, external mode [world's first]: The optimal temperature control algorithm minimizes deviation and optimizes the temperature of the incubator through automatic external temperature feedback control.

Sample mode: Adjust the optimal temperature of the incubator by measuring the temperature of the sample or target.Manual mode: By setting the temperature required by the user, the environment required by the researchers can be achieved

Easy to use: Provides multiple chamber types, magnetic connection cables, patented magnetic connections, easy to install and maintain, simple to connect,Sliding incubator cover, fully open incubator cover

The incubator can maintain a humidity of over 90%, is compatible with various microscopes, has a compact system, is easy to assemble, and can be customized for users,The water reservoir around the sample rack helps to maintain humidity and prevent medium evaporation.

Temperature controller: Provide stable and precise sample temperature control for long-term imaging. usePIDControl can maintain the temperature of all heating components, including the incubator cover, incubator body, humidifier, and lens heater.

3Heating control: external, sample, manual mode;4Heating channels: incubator cover, main body, humidifier, lens heater;Simple cable connection with colored connectors;Stable and durable temperature distribution;Real time thermal response, graphics, and alarm functions;All parametersPIDcontrol

Gas mixer:Provide precise concentrations for research applicationsCO2N2perhapsO2Gas; carryofferings3Types of gas controllers;Electromagnetic valves and gas storage tanks for uniform mixing of gases;PIDControl system adjusts gas concentration;Internal air pump to ensure stable airflow;Connect directly and quickly through fittings

Humidifier:Humidifiers help maintain relative humidity in the incubator, preventing evaporation that may cause cell damage.CO2Gas flows into the incubator through the humidifier sensor controlled hot water;Maintain saturated humidity inside the incubator;Maintain the osmotic pressure of the medium by preventing evaporation;Internal thermal sensor for precise feedbackmagnetic connector

Lens heater:For high-resolution imaging, it is necessary to control the temperature of the immersion objective lens. Oil, glycerol, or water act as thermal coupling media to remove heat from the sample. To avoid heat loss, please wrap the lens heater around the objective lens to generate and maintain an appropriate temperature. Its silicone strap is suitable for all types of objective lenses.

Used for high magnification and high-resolution imaging; pickUsing magnetic connection technology to prevent ropes from tangling or breaking due to excessive tension; monopolizeWrap the lens with silicone material and a heating strip without gaps to prevent sample heat dissipation

Remote touch screen panel:AndroidThe tablet provides an intuitive graphical screen for controlling all the parameters required for the incubator system;Control the system and all parameters through smartphones and other devices;An intuitive and user-friendly graphical interface for real-time temperature control and control; sendusePCAutomatically save and check real-time data;Online troubleshooting

Graphic User Interface:Incubator systemTIntuitive and easy-to-use, it can be remotely controlled through applications on smartphones and other mobile devices. Operators can control all parameters of the system in real-time anytime, anywhere.

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!