English

Vikteri (Beijing) Technology Co., Ltd
Home>Products>Super constant temperature water (oil) tank
Super constant temperature water (oil) tank
Can fully design and produce non-standard products according to user requirements
Product details
Super Constant Temperature Water (Oil) Tank Series
(with liquid level alarm function)

★ Can design and produce non-standard products completely according to user requirements

Application areas:
Biochemical field: rotary evaporator, Abbe refractometer, polarimeter, atomic absorption spectroscopy ICP-MS、ICP、 Nuclear magnetic resonance CCD、 Biological fermentation tanks, chemical reactors, etc
◆ Medical field: Superconducting magnetic resonance, linear accelerator CT、 Low magnetic field nuclear magnetic resonance, X-ray machine, microwave therapy machine, medical cold cap, cooling blanket, etc
◆ Physical and chemical fields: lasers, magnetic fields, various molecular pumps, diffusion pumps, ion pumps, and various water-cooled equipment used in the materials field
Materials field: electron microscopy, X-ray diffraction, X-ray fluorescence, vacuum sputtering electroplating, vacuum coating machine, ICP etching, various semiconductor equipment, fatigue testing machine, chemical deposition system, atomic deposition system, etc

Scope of use:
CNC super constant temperature water and oil tanks are widely used in fields such as chemical engineering, petroleum, medicine, biology, physical chemistry, metrology control, electronic instrument processing, etc

Main features:
◎ Microcomputer intelligent control, large screen high brightness LCD screen, bilingual display in Chinese and English
Built in AA grade high-precision PT100 temperature sensor
The inner liner and countertop are made of high-quality S304 brushed stainless steel panel
Dual use of water and oil, free choice of high and low temperatures (medium selected according to temperature range: pure water, methyl silicone oil, etc.)
◎ Humanized R-rounded design structure for front panel and countertop to avoid scratches
◎ External circulation function: The centrifugal jet circulation pump can draw out the constant temperature liquid in the tank, establish a second constant temperature field, and control the external experimental container of the machine
Internal circulation function: Adopting a non heat centrifugal circulation pump to avoid the influence of traditional water pumps on the tank temperature field due to their own heat generation. The internal circulation system is designed based on the principle of porous U-shaped reflux circulation, achieving turbulent and highly uniform flow and temperature fields inside the tank
The drainage system can meet the needs of various laboratories and enterprises for liquid exchange production
◎ Safety protection device:
1. Equipped with power-off protection function
2. Equipped with upper and lower temperature alarm setting function
3. Low water level protection and alarm function
4. Temperature runaway protection and alarm function
5. The heating tube has low water level anti dry burning and explosion-proof functions
◎ Digital display resolution: 0.01 ℃
◎ Temperature fluctuation value: ± 0.02 ℃
◎ Temperature uniformity: ± 0.05 ℃ horizontal/vertical

Optional Function Guide:
1. An optional extended external PT100 temperature sensor can be used to detect and control the temperature of the external system in real-time during external circulation
2. Optional built-in 1-30 segment temperature control program for automatic program temperature control, real-time display of set temperature time program running status
3. Optional RS232 or RS485 communication interface, easy to connect to the upper computer Modbus RTU communication protocol
4. Optional design and installation of magnetic stirring system, which can directly perform magnetic stirring on the sample placed in the beaker of the constant temperature bath working room, without the need for an external vertical stirrer, reducing redundant operations. At the same time, it can achieve closed processing and reduce the loss of fog generated during the stirring process
5. Optional cooling coils built into the tank can quickly cool and control the exothermic reaction of the system
6. Optional height adjustable immersion platform for easy adjustment of the liquid level of the immersed sample



Technical parameters:
Model number Temperature range (℃) Temperature uniformity
(Horizontal/Vertical ℃)
Inner groove size (mm)
(Length X Width X Slot Depth)
capacity
(L)
Circulation mode
(Internal/External)
Work slot opening
(mm2)
drainage
VKSC-5 Room temperature~100 ±0.05 275×190×120 5 Internal circulation 180×140 have
VKSC-5A Room temperature~200 ±0.05 275×190×120 5 Internal circulation 180×140 have
VKSC-5D Room temperature~300 ±0.05 275×190×120 5 Internal circulation 180×140 /
VKSC-10 Room temperature~100 ±0.05 275×195×180 10 Internal circulation 180×140 have
VKSC-10A Room temperature~200 ±0.05 275×195×180 10 Internal circulation 180×140 have
VKSC-10D Room temperature~300 ±0.05 275×195×180 10 Internal circulation 180×140 /
VKSC-15 Room temperature~100 ±0.05 300×250×200 15 External circulation 6L/min 235×160 have
VKSC-15A Room temperature~200 ±0.05 300×250×200 15 Internal circulation 235×160 have
VKSC-15D Room temperature~300 ±0.05 300×250×200 15 Internal circulation 235×160 /
VKSC-20 Room temperature~100 ±0.05 300×250×270 20 External circulation 6L/min 235×160 have
VKSC-20A Room temperature~200 ±0.05 300×250×270 20 Internal circulation 235×160 have
VKSC-20D Room temperature~300 ±0.05 300×250×270 20 Internal circulation 235×160 /
VKSC-25 Room temperature~100 ±0.05 300×250×335 25 External circulation 6L/min 235×160 have
VKSC-25A Room temperature~200 ±0.05 300×250×335 25 Internal circulation 235×160 have
VKSC-25D Room temperature~300 ±0.05 300×250×335 25 Internal circulation 235×160 /
VKSC-30 Room temperature~100 ±0.05 440×325×210 30 External circulation 6L/min 310×280 have
VKSC-30A Room temperature~200 ±0.05 440×325×210 30 Internal circulation 310×280 have
VKSC-30D Room temperature~300 ±0.05 440×325×210 30 Internal circulation 310×280 /
VKSC-40 Room temperature~100 ±0.05 500×340×240 40 External circulation 6L/min 350×300 have
VKSC-40A Room temperature~200 ±0.05 500×340×240 40 Internal circulation 350×300 have
VKSC-40D Room temperature~300 ±0.05 500×340×240 40 Internal circulation 350×300 /
VKSC-50 Room temperature~100 ±0.05 500×340×300 50 External circulation 6L/min 350×300 have
VKSC-50A Room temperature~200 ±0.05 500×340×300 50 Internal circulation 350×300 have
VKSC-50D Room temperature~300 ±0.05 500×340×300 50 Internal circulation 350×300 /
VKSC-100 Room temperature~100 ±0.05 625×400×400 100 External circulation 6L/min 480×380 have
VKSC-100A Room temperature~200 ±0.05 625×400×400 100 Internal circulation 480×380 have
VKSC-100D Room temperature~300 ±0.05 625×400×400 100 Internal circulation 480×380 /


Manufacturer friendly reminder - When selecting a thermostatic bath, the following points should be considered:
1. Firstly, what is the range of temperature required for use? What medium is used as the temperature field carrier, and the medium used varies depending on the temperature range. The medium is generally selected according to the temperature range: ethylene glycol for water (low temperature), alcohol (ultra-low temperature), pure water (5-95 ℃), imported dimethyl silicone oil (suitable for high and low temperatures), etc
2. Choose the appropriate capacity of the constant temperature bath based on your actual situation. The correct calculation method for effective working volume is: the opening size of the working bath plus the bath depth, in millimeters
3. It is a requirement for the temperature uniformity of the constant temperature bath temperature field. Our company is divided into two categories: 1. Ordinary type: ± 0.05 ℃ 2. Ultra high precision type: ± 0.0020 ℃
4. What is the maximum head of the external circulation function based on the usage situation

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!