VIP member
Step by step rain shower room
Product use: The locomotive waterproof test room is suitable for testing the waterproof sealing of outdoor motor trains. Through the waterproof test r
Product details
| host important join number |
Size of workspace | 7000×4000×4000(D*W*H)mm | |||||
| Nozzle Diameter | Φ2.5—3.0mm | ||||||
| spraying density | 550×550mm | ||||||
| Water supply pressure | 150±10KPa | ||||||
| Spray device diameter | Depending on traffic volume | ||||||
|---|---|---|---|---|---|---|---|
| Pressure | 1.5 level precision pressure gauge, dial with a diameter of 100, 0-6kg/cm ², using a pressure sensor | ||||||
| flow meter | Electromagnetic Flowmeter | ||||||
| rain gauge | Depending on traffic volume | ||||||
| Standard configuration | Water pump, sewage pump, filter | ||||||
| Rain time | Adjustable | ||||||
| supply voltage | AC380V±10% 50Hz | ||||||
| fall rain |
Upper part of front wall | 6mm±1mm/min | |||||
| Side and top | 8mm±1mm /min | ||||||
| Other | Equipped with one IPX5 and one IPX6 nozzle each | ||||||
| Note: 1. The above data were measured under good ventilation conditions at an ambient temperature of 25 ℃ 2. We can customize non-standard laboratories according to specific user requirements 3. This technical information is subject to change without prior notice |
|||||||