Product Application
Heating, Ventilation, and Air Conditioning (HVAC)
■ Transmission machinery
Heating and drying equipment
■ Packaging Machinery
Hydraulic devices in industries such as pharmaceuticals, food, electricity, metallurgy, glass, chemicals, rubber, and textiles
Technical data
| insulation resistance | When the ambient temperature is within the range of (15-35) ℃ |
| When the relative humidity is less than 80% | |
| The insulation resistance value of platinum resistance should be greater than 100M Ω | |
| Self heating effect | Thermal resistance allows a maximum measured current of 2-5mA |
| The resulting temperature rise shall not exceed 0.3 ℃ | |
| Minimum depth of placement | ≥10mm, Excluding special products |
| process connection | Stainless steel, threaded |
| Protection tube | Stainless steel, 2mm, 3mm, 4mm, 6mm, 8mm |
| response time | t0.5,10s~90s |
| accuracy class | Pt100, Class A: ± (0.15+0.002 | t |) |
| Grade B: ± (0.30+0.005 | t |) | |
| | t | "is the absolute value of the measured temperature of the temperature sensing element | |
| connecting wire | Silicone, ambient temperature -50~180 ℃ |
| Electrical connection | The end of the wire is exposed and can be equipped with a cold press connector or a multi pin connector |
| Electrical connection | Two wire system, three wire system |
Instructions
·The standard for cable connection ends is to directly expose the outgoing line. If you need a cold pressed joint or socket, please consult our sales personnel and indicate it when selecting;
·The standard for the connection of the protective tube outlet does not include anti bending protection. If you need to choose spring or hose anti bending protection, please consult our sales personnel and indicate it when selecting;
·The protective tube and process connection material come standard with stainless steel 1.4301. For other stainless steel materials, please consult our sales staff and specify when selecting;
·For special ranges or the use of other temperature sensing components such as Pt500, Pt1000, etc., please consult our sales personnel and specify when selecting.