Standard Microcrystalline COD Dissolver

Main parameters
The products produced by our companyStandard Microcrystalline COD DissolverThere are three specifications, 6 holes/8 holes/12 holes
| Instrument model | KAS-106 | KAS-108/KAS-208 | KAS-12W |
| Sample heating quantity | 6 (24 # ground conical bottles) | 8 (24 # ground conical bottles) | 12 (24 # ground mouth cylindrical bottles) |
| Heating panel material | Microcrystalline panel | ||
| Support cooling methods | Simultaneously supporting fan cooling and distilled water cooling | ||
| Number of cooling fans | Dual fan | ||
| Time and Temperature | 165-350℃,5-150min | ||
| heating power | 1500-2000W | ||
| Instrument power supply | AC(220V±5%),50Hz | ||
| working environment | 5-40 ℃, ≤ 85% non condensing | ||
| Instrument size | 440mm*330mm*570mm | ||
| Instrument weight | About 15kg | ||
| execution standard | Complies with both HJ828-2017 and GB11914-89 standards | ||
| measurement range | 10~1000mg/L、 Dilute water samples with a concentration greater than 1000mg/L | ||
| digestion time | 10 minutes to 2 hours | ||
| measurement error | The relative standard deviation of potassium hydrogen phthalate standard solution (500mg/L) is not more than 5.0% The relative standard deviation of industrial organic wastewater (500mg/L) is not more than 7.0% |
||
Main Features
The digestion device adopts imported microcrystalline panels. The panel is a high-temperature resistant microcrystalline board that can withstand 800 ℃, with uniform heating on the surface and fast heating and cooling rates. The heating part uses a new type of imported high-temperature resistant ceramic fiber heating plate. The bottom plate and surrounding heat loss of the digester are small, and the heating and thermal conductivity are uniform, resulting in higher thermal efficiency
1 . Microcrystalline panels are flat, smooth, and easy to clean; If the surface is contaminated, simply wipe it dry with a cloth to reduce damage to the instrument caused by improper operation.
2 . The new type of glass burr reflux tube and heat dissipation system ensures the parallelism and accuracy of sample digestion results due to its excellent digestion reflux effect. 3 . Digital display of microcrystalline panel temperature, temperature range (between 165 ℃ -350 ℃).
4 . Digital display of digestion time: The digestion time is between 5 minutes and 150 minutes.
5 . After digestion is complete, the instrument automatically stops heating, and the instrument fan continues to work for 120 minutes to assist in sample cooling. It can be left unattended.
6 . Energy and water conservation, safety and reliability have improved the work efficiency of operators.