1、 Equipment composition
2、 Equipment principle
The product has three functions: measuring average flow velocity, measuring water depth, measuring water temperature, and can display cross-sectional flow rate.
Among them, temperature sensors are used for water temperature measurement, ultrasonic water level gauges are used for water depth measurement, and flow velocity measurement is achieved through installation
Yu QuRoad sideOn the wallMeasured by four sets of ultrasonic probes.By measuring the average flow velocity, water level, and cross-sectional size, the cross-sectional area can be determined
Traffic.
3、 Application scope
Mainly suitable for widths less thanA 1-meter rectangular regular channel.
4、 Equipment installation
5、 Characteristics
1.The velocity area method is used to measure small channel flow with high accuracy;
2.Side wall installation, anti silt and anti-theft;
3. Integrated design, the flow velocity probe can be installed and disassembled in combination, making maintenance simple;
4.Micro power design, battery powered for continuous use3 months;
5. Low price.
·Number of sensor groups: 4 groups.
·Range: 21mm/s to 5000mm/s.
·Accuracy: ± 1% of the measured flow rate.
·Resolution: 1mm/s.
·Temperature:
·Range: 0 ℃ to 60 ℃.
·Resolution: 0.2 ℃.
·Water level:
·Range: 0-2m
·Resolution: 1 mm.
·Accuracy: ± 0.5% of the measured water level.
·Traffic:
·Accuracy: ± 2% of the measured flow rate.
·Power supply:
12V DC or 220V AC.
·Interface:
Standard RS232, RS485, 4-20mA.
·Communication protocol:
Modbus。
·Data storage capacity:
Collect a record every 2 minutes and store data for more than 3 months.
·Operating temperature:
The water temperature ranges from 0 ℃ to 60 ℃.
·Shell material:
PC or PVC plastic.
·Shell protection level:
IP68。
·Reliability:
MTBF≥25000h。