Shanghai Jinlan Instrument Manufacturing Co., Ltd
Home>Products>Single/double ultra clean workbench
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    13621789750
  • Address
    7F, No. 37 Gucun Industrial Park, Baoshan District, Shanghai
Contact Now
Single/double ultra clean workbench
1、 Overview: A super clean workbench is an air purification device designed to provide a locally clean space and a pollution-free working environment
Product details
单/双人超净工作台
1. Overview:
A super clean workbench is an air purification device designed to provide a locally clean space and pollution-free working environment in a specific environment. The external air passes through a primary filter, is sucked in by a circulating fan with built-in air volume in the workbench, and then passes through a high-efficiency filter to be filtered and cleaned again. Small particles and suspended solids in the air are intercepted, and relatively high cleanliness air is provided from the side or top. Clean air is blown at a constant speed from the working face to replace the ambient air in the working area, thereby purifying the working environment. The Jinlan series ultra clean workbench is widely used in fields such as microbiology, biochemistry, medical treatment, biopharmaceuticals, and university research.
2、 Characteristics:
1. Cold rolled steel forging, surface electrostatic spraying, stainless steel production in the working area
2. Quasi closed glass door with high air tightness to prevent external infiltration. Equipped with universal wheels, easy to move.
3. Adjustable air volume centrifugal fan, remote control switch control, fast and slow dual speed.
4. Spring style up and down sliding doors, easy to open.
5. Air curtain isolation design, to accommodate internal and external cross infection.
6. The workspace is made of high-quality stainless steel, which isolates cross contamination, prevents rust, and is easy to clean.
7. Dual speed design with fast and slow wind speed.
8. Moderate size, occupying a small area of space. It can be used as a single unit or connected in series to form a production line.
Note: 1. Optional LCD display switch control.
2. For industries such as biopharmaceuticals and chemical research that produce gases and particles that can affect the human body and cause allergies, vertical air supply ultra clean workbenches should be selected.
3、 Vertical air supply ultra clean workbench:
单/双人超净工作台

Model JL-CJ-H1B JL-CJ-H2B JL-CJ-H1D JL-CJ-H2D
cleanliness level Level 100 @ ≥ 0.5 μ M (Federal 209E)
colony count ≤ 0.5 per dish · hour (in a Φ 90mm culture dish)
average wind speed 0.25-0.45m/s (fast and slow dual speed)
noise ≤62dB(A)
Vibration half peak value ≤ 0.5 μ M (x, y, z direction)
illuminance ≥300Lux
power supply AC single-phase 220V/50Hz
maximum power 130W 300W 400W 800W
weight 85Kg 150Kg 100Kg 160Kg
Size of workspace (mm)
W1×D1×H1
700×500×520 1150×500×520 870×600×520 1360×600×520
Overall dimensions (mm)
W×D×H
850×580×1600 1300×580×1600 1050×680×1600 1540×680×1600
Applicable number of people Single person/single-sided Double/Single sided Single/Double sided Double/Double sided
Specification and quantity of high-efficiency filters 695×460×38×① 1135×460×38×① 865×555×38×① 1355×555×38×①
Specification and quantity of fluorescent/ultraviolet lamps 15W×①/15W×① 30W×①/30W×① 20W×①/20W×① 30W×①/30

4、 Horizontal air supply ultra clean workbench:
Model JL-CJ-W1B JL-CJ-W2B
cleanliness level Level 100 @ ≥ 0.5 μ M (Federal 209E)
colony count ≤ 0.5 per dish · hour (in a Φ 90mm culture dish)
average wind speed 0.25-0.45m/s (fast and slow dual speed)
noise ≤62dB(A)
Vibration half peak value ≤ 0.5 μ M (x, y, z direction)
illuminance ≥300Lx
power supply AC single-phase 220V/50Hz
maximum power 130W 300W
weight 85Kg 150Kg
Size of workspace (mm)
W×D×H
700×400×600 1150×400×600
Dimensions (mm)
W×D×H
850×580×1600 1300×580×1600
Applicable number of people Single person/single-sided Double/Single sided
Specification and quantity of high-efficiency filters 695×600×38×① 1135×600×38×①
Specification and quantity of fluorescent/ultraviolet lamps
15W×①/15W×① 30W×①/30W×①
单/双人超净工作台
5、 Attention:
The workstation should be located in a relatively clean working environment (preferably in a primary purification room of 100000 or 300000 levels), plugged in the power, and turned on according to the functions shown on the control panel. Before starting up, the working area and shell of the purification workstation should be thoroughly cleaned to remove surface dust. Normal operation and use can be carried out within ten minutes after starting up.
1. According to actual usage, regularly remove and clean the primary filter, with a cleaning cycle of generally 3-6 months. If not cleaned for a long time, dust accumulation will affect the insufficient air intake and reduce the cleaning effect
2. When the ideal cross-sectional wind speed cannot be achieved after normal replacement or cleaning of the primary filter air filter, the operating voltage of the fan should be adjusted to achieve the ideal uniform wind speed.
3. Generally, when the operating voltage of the fan is adjusted to the highest point after 18 days of use and the ideal wind speed cannot be achieved, it indicates that the high-efficiency filter has accumulated too much dust (the filter holes on the filter material are basically blocked and need to be updated in a timely manner). The service life of a high-efficiency air filter is generally 18 months.
4. When replacing the high-efficiency air filter, attention should be paid to the correctness of the model, specifications, and dimensions (as configured by the original manufacturer), install the device according to the direction of the arrow, and ensure that the surrounding seal of the filter is sealed and there is no leakage.

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!