Principle of Side Stream Processor
Product details

Introduction to Side Stream Processor


The PDII-F/G series circulating water bypass processor is developed based on the original full flow water processor. This water processor adopts the principle of low-voltage electric field with superimposed pulses, automatically adjusts the processing signal according to water quality, and only requires bypass treatment. The product is suitable for sterilization, algae removal, scale removal, and removal of suspended solids in circulating water systems.

In many occasions, the cooling tower scale absorber and the bypass water processor can be replaced by each other. In open circulating water systems, it is recommended to install a shallow medium filter after the bypass water processor to reduce water turbidity.


Principle of Side Stream Processor

Pulse low-voltage electric field generates microcrystals with excellent descaling function, which can continuously prevent scaling for 48 hours; The patented electrode with catalytic activity produces strong bactericidal factors such as reactive oxygen species, which can kill bacteria and algae; Active substances form Fe on the inner wall of carbon steel water pipes3O4Dense protective film to prevent corrosion; Suspended solids in water are efficiently separated and discharged from the system in the water processor, resulting in cleaner water quality.

These oxidizing substances diffuse through the flow of water to all places where water passes, killing bacteria and algae cells in the water system. The bacteria and algae cells in the water flowing through the water treatment plant are directly killed by the current, and the reactive oxygen species form an oxide film on the pipeline to protect the equipment from further corrosion. Various microbial and sedimentary corrosion are inhibited.


Side stream processor function

Kill bacteria in water
Waterproof and scale removal
Kill Legionella bacteria
Corrosion prevention of equipment pipelines
Suppress and eliminate algae


Processing effect of bypass flow processor

The heat exchange surface of the heat exchanger is free of scale, maintaining efficient heat transfer
The total number of bacteria in the cooling water is lower than the national standard value
No algae growth in cooling water
Kill Legionella bacteria, meet national standards, and prevent 'Legionella SARS'
The inner wall of carbon steel water pipes gradually forms a dense Fe3O4 protective film to solve the problem of yellow rust water, and the corrosion rate is lower than the specified value of national standards
The water quality indicators of the cooling water have fully met the national industrial circulating cooling water quality standards (GB50050-95)

Visible descaling

After passing through the processor, the degree of polymerization of water molecules decreases, and the structure undergoes deformation, resulting in a series of small elastic changes in physical and chemical properties, such as an increase in the dipole moment and polarity of water, thereby increasing its hydration and scaling ability.

Specific energy fields alter the crystallization process of CaCO3, inhibiting the production of calcite and providing energy for the formation of aragonite crystals.

Under the action of electrodes, the processor generates a large number of microcrystals with excellent anti scaling function. Microcrystals can preferentially remove easily scaling ions in water, forming loose aragonite, which is discharged through an automatic valve into the scale collection device outside the system for easy observation of the descaling effect. The descaling is visible.

Broad spectrum sterilization and algae killing

During the process of treating water with an electric field, dissolved oxygen is activated to produce oxygen2-、 ·OH, H2O2And reactive oxygen species such as 1O2 (O)2-Is a superoxide anion radical, · OH is a hydroxyl radical, H2O2It's hydrogen peroxide. Reactive oxygen species have a killing effect on microbial organisms and are the main cause of microbial aging. (1).O2-Can damage important biomolecules and cause damage to microbial organisms; (2).O2-Increase microbial collective membrane lipid peroxidation and accelerate aging.

Microorganisms that can be killed (bacteria, viruses)

Legionella pneumophila, Chlamydia, Mycoplasma, Escherichia coli, Staphylococcus aureus, Bacillus subtilis, Bacillus subtilis, Shigella, Neisseria meningitidis, Mycobacterium tuberculosis, hepatitis virus, respiratory virus, etc.

Algae that can be killed

Green algae: Chlorella vulgaris, Scenedesmus obliquus, Naked algae, Scenedesmus obliquus, Firmicutes, Scenedesmus obliquus, Chaetoceros obliquus;
Cyanobacteria: Spirulina, Microcystis, Diatoms, etc.

Oxidation film anti-corrosion

Reactive oxygen species form an oxide film on the pipeline wall, preventing pipeline corrosion. During operation, reactive oxygen species have an impact on
The water pipe wall is continuously coated and passivated.

Microbial corrosion and sedimentary corrosion are inhibited.


Picture of Open Cooling Water Side Flow Processor

blob.png

Image of Closed Chilled Water Side Flow Processor

blob.png


Comparison of Side Stream Processor Before and After Scale Removal

blob.png

Comparison of Before and After Algae Removal by Side Stream Processor

blob.png


Control mode of bypass flow processor

Automatic control: pressure difference/time can be controlled simultaneously or separately, and can be selected according to actual working conditions and needs. It can also be manually forced to discharge.

Manual control: Manually open the drain valve to discharge water.


Characteristics of Side Stream Processor

1. Only 1-3% of the water flow rate of the bypass treatment system is required, making installation easy;

2. Good descaling effect;

3. Using powerful pulsed electric fields to kill Legionella bacteria;

4. Remove rust and yellow water; Reduce turbidity;

5. The effect is intuitive and visible;

6. No need for chemical agents, no secondary pollution, green and environmentally friendly;

7. Intelligent and fully automated operation.


Scope of application of bypass flow processor

1. Central air conditioning refrigeration and cooling water system.

2. Industrial cooling circulating water system.

3. Refrigeration cycle water system.

4. Various heat exchange systems and cooling tower systems.

5. Boiler and heating system.


Technical parameters of bypass flow processor

Input power supply: 220V, 50HZ

Working voltage:<36V

Applicable water temperature: 0 ℃~95 ℃

Head loss: 0.2~1.0m

Scale removal and inhibition efficiency: 100%

Sterilization rate:>99%

Corrosion rate: meets national standards

Applicable water quality: CaCO3count

Total hardness:<700mg/L


Structural diagram of bypass flow processor

blob.png

Closed chilled water side flow processor structure Open cooling water side flow processor structure


Model Description of Open Cooling Water Side Flow Processor

blob.png

Ftype(Special type bypass water processor for open cooling water system)Specifications, dimensions, and technical parameters

blob.png

blob.png


Model Description of Closed Chilled Water Side Flow Processor

blob.png

Gtype(Special type bypass water processor for closed chilled water system)Specifications, dimensions, and technical parameters

blob.png


blob.png


Selection of Side Stream Processor


AThe open cooling water system should choose F-type and select the water processor according to the pipe diameter indicated by the F-type specification.
B、 The closed circulating water system should be selected as G-type, and the water processor should be selected according to the pipe diameter indicated by the G-type specification

Due to the significant differences between open cooling water systems and closed circulating water systems (as shown in the table below), different water treatment units must be used for water quality treatment based on their respective characteristics. The F-type water processor is designed specifically for open cooling water systems, while the G-type water processor is designed specifically for closed circulating water systems.

blob.png


Before selecting, there must be clear supplementary water quality reports, water quality standards, circulating water quality standards, working pressure, working temperature, flow rate, and equipment material parameters.


Installation diagram of bypass flow processor

blob.png


Precautions for installation of bypass flow processor


When designing and installing, a position should be reserved for the installation of the bypass water processor near the system water pump. The inlet of the bypass water processor is connected to the outlet pipe of the system water pump, and the outlet is connected to the inlet pipe of the system water pump;
During equipment installation, a maintenance space of no less than 600mm should be left around the perimeter;
3. The bypass water processor should be installed indoors with good ventilation. If it must be installed outdoors, a rainproof device should be installed; During installation and handling, do not subject the electronic controller to pressure or moisture;
4. Pressure gauges should be installed near the inlet and outlet of the bypass water processor, and the water pressure at the inlet and outlet can reflect the working condition of the water processor;
5. For the new system, before the system is officially put into use, the entire pipeline system must be flushed to remove impurities such as welding slag, iron wire, steel pipe oxide scale, and to drain the yellow rust water in the system. For old systems with severe scaling (scale thickness>2mm), the scale should be removed before installing the bypass water processor to prevent the old scale from falling off and blocking the pipeline.

Precautions for using the bypass flow processor


(1) The product has been adjusted by the technical inspection department before leaving the factory, and users do not need to adjust it themselves.
(2) When the power is turned on, the operation indicator light is on;
(3) When the automatic discharge is activated, the cleaning indicator light is on.
(4) When a malfunction occurs, the fault indicator light will turn on, and the manufacturer should be notified promptly for repair.


Partial Case Study of Side Stream Processor on Site

blob.png

Application: Anti scaling and descaling for air conditioning cooling circulating water systems

Customer: Shanghai Shuanghui Building

Core advantage: thorough descaling, stable and reliable operation

Overview of Side Stream Processor: Quantity 2, Main Pipe Diameter DN250

Project Overview: The total base area is approximately 50430 square meters. The Pujiang Shuanghui Building on plot 2E2-2 consists of two 49 story super high-rise office buildings and four underground floors, with a total construction area of approximately 291410 square meters and a main building height of 218.6 meters.

blob.png

Application: Used for scale prevention and algae removal in air conditioning cooling water systems

Customer: Changzhou Global Port

Core advantage: thorough descaling, stable and reliable operation

Overview of Side Stream Processor:

Main pipe diameter: DN600 Circulating water volume: 2800T/H Equipment pressure: 1.0MPa Power: 500W Quantity: 2 units

Main pipe diameter: DN500 Circulating water volume: 2000T/H Equipment pressure: 1.0MPa Power: 300W Quantity: 2 units

Project Overview: 5 outdoor public squares, 29820 square meters rooftop sky garden, 300 meter long art landscape avenue, 3 atrium squares, 70000 square meters theme park, integrating leisure, entertainment, office, shopping, and living.

blob.png

Application: Used for descaling and anti scaling of air conditioning cooling water systems

Customer: A pharmaceutical factory in Shanghai

Core advantage: thorough descaling, stable and reliable operation

Overview of Side Stream Processing Unit: Quantity 2, Main Pipe Diameter DN200

Project Overview: Covering an area of 120000 square meters. There are seven production workshops, two auxiliary workshops, and four branch factories, with research institutes and education centers, as well as well-equipped comprehensive waste treatment facilities.

blob.png

Application: Anti scaling and anti-corrosion for chilled circulating water systems

Customer: A building in Wuxi

Core advantage: thorough descaling, stable and reliable operation

Overview of Side Stream Processor:

Main pipe diameter: DN450 Inlet and outlet diameter: DN40 National standard sewage outlet diameter: DN20 Equipment pressure: 1.0MPa Power: 300W Quantity: 1 unit

Project Overview: The total construction area is 136000 square meters, with 48 floors and a peak height of 248 meters. It is the first landmark in Wuxi city, integrating top shopping centers, international Grade A office buildings, ultra luxury hotel style apartments, and VIP private clubs.


Packing diagram of bypass flow processor

blob.png

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!