product overview:

The STKC3312 series is a wireless torque sensor that is suitable for various harsh environments (having been tested in various harsh environments such as wilderness and high pollution in the petroleum and shipbuilding industries).
If measuring in the short term, battery power can be used. If measuring for a long time, it is recommended to use our company's developed uninterruptible power supply technology, which does not require charging and is not affected by battery life, and can work continuously for a long time.
This sensor can also be applied to any project that requires measurement of rotating components, and can simultaneously perform multi-channel (multi parameter) measurement and data transmission. It can also be modified to be mounted to adapt to the measurement of rotating components with more complex shapes.
Product features:
● Convenient and fast, installation can be completed in fifteen minutes
Wireless communication, with a transmission distance of up to 100 meters
Data encryption technology enhances anti-interference ability
● Fully sealed design, suitable for various harsh environments
Extremely compact design, occupying very little space
● Standard precision level 1, high precision level 0.3
Modular design, one sensor can measure multiple shaft diameters
Technical parameters:
| type | describe | |
| Accuracy class | 1 (Standard) | |
| 0.3 (optional) | ||
| Linearity error | % | <1 |
| Relative standard deviation of repeatability error | % | <1 |
| Hysteresis lagging behind | % | <1 |
| Long term drift over 48 hours | % | <1 |
| Measurement frequency range -3 dB | kHz | 0.2 (standard) |
| 1.0 (optional) | ||
| Temperature drift effect of temperature per 10 ° C | % | 1 (+10~60°C)2 (-20~70°C) |
| Overload capacity limit torque, related to Mnom fracture overload breaking torque, related to Mnom | % | 150 |
| % | 300 | |
| Degree of protection per EN 60 529 | IP 54 (standard) IP 68 (optional) | |
| Reference temperature Recommended temperature: Nominal (rated) temperature range Operating temperature range Storage temperature range |
°C °C °C °C |
22+ 10 … +50 20 … +60 30 … +85 |
| Power supply Nominal (rated) supply voltage Measure current consumption in measuring Current consumption in startup mode Rated power consumption |
V A A W |
24 DC ±5% < 0.2 (typ. 0.1) < 0.5 (typ. 0.3) 50 μs < 0.1 |
| Battery Voltage Working Time Endurance | Vhours | 98(48/168optional)1yearoptional) |
| Output output | Wireless communication (2.4G Hz) | |
Tags: Sensor, Torque Sensor