SF6 gasrecovery unit(DILO-B120R21)
GermanyDILOImported with original packaging, selling well worldwide;Quality assurance,6Integrated functionality!
Overview
SF6 gasRecycling device(DILO-B120R21)It's GermanyDILOOne of the company's technologically advanced and highly recyclable products,Weaver'sWe have established a good cooperative relationship with them, have full agency rights, and provide spare parts and continuous guarantee services.WIFOSSThe company willDILO-B120R21 SF6 gasPromote the application of recycling devices throughout the Asia Pacific region, bringing more professional services to users in the regionSF6Solution strategies for gas recovery devices and a full range of product issues.


Equipment Introduction
The equipment consists of the following components:
l Electrical ControlThe power socket installed inside the control cabinet generates power.(Whether the phase is correct is monitored by the steering induction controller)All indicator lights and buttons are marked and installed inside the control cabinet door. The running time is indicated by the working time counter. The control panel inside the control cabinet door has two functions.1Display the gas process with pre selected automatic function.2. Manually open the valve through the illuminated button display.
l manual operation: Translate into English“Functions”Switch to0: Manual operation”Perform manual operation. Pre select all valves one by one through the installed illuminated buttons(LEDsshining)If an incorrect valve is selected, all selected valves can be passed through“Reset the valve”Restart(LEDsextinguish)Pre selected valves can be used through“Open the valve”The button is opened(LEDsThe light is on)The solenoid valve can only open upwards from the evaporator when it reaches the operating temperature(Only applicable to liquid storage)The solenoid valve can only be opened from the vacuum pump when there is no overpressure present while the vacuum pump is being evacuated. Attention: When used0: Manual operation”When functioning, it is reliable to operate the correct gas treatment for oneself.
l Zhen Zhen PumpThe vacuum pump and vacuum measuring device have been protected against overvoltage. Therefore, it can avoid instrument damage caused by overvoltage. The solenoid valve can only be opened from the vacuum pump when there is no overpressure present during the evacuation process. If this solenoid valve is pre selected together with other solenoid valves, they cannot be opened either. Reduce the use of compressors and vacuum compressorsSF6Gas overpressure has occurred“Gas recovery”It is described in the functional description. Release air and nitrogen through ventilation valves. The vacuum pump is only discharged into the atmosphere.
l compressorThe compressor is a dry compressor and operates without oil, which can produce different outputs and final pressures. The airtightness of the compressor pipeline should be absolutely intact. But the maintenance of the compressor will be easier to implement. Overpressure operation can be controlled by pressure reducers and contact meters.
l Vacuum compressorDry type vacuum compressors are protected during operation by voltage regulators, solenoid valves, and check valves. When gas is recovered, the vacuum compressor is in the automatic on/off state.
l Dry filter, particle filter:SF6The gas is purified by the particle filter in the equipment and dried through a drying filter. Each gas treatment processSF6All gases need to pass through these filters.
Maintenance of storage containers-:SF6Stored in gaseous form, it can also be stored in liquid form under corresponding high-pressure conditions. How to distinguish the storage status in a pressure tank:25bar(360psi)When in a gaseous state,50bar(725psi)When in liquid state(Attention!Pressure vessels cannot be usedSF6Transportation of gases)During transportation, it should be stored in transport bottles. For liquid storageSF6It can be observed from the weight indicator.

Technical Specifications
|
project |
indicator |
|||
|
pressure tank |
Storage capacity |
storage capacity |
length |
width |
|
300L |
280kg |
1860 |
950 |
|
|
vacuum pump |
Standard inhalation volume |
Final vacuum degree |
|
|
|
25 m3/h(15 cfm) |
<2x10-3 mbar (<1.5xlO-3 mm Hg)
|
|
|
|
|
compressor |
Theoretical compression amount |
Final pressure value |
Maximum pressure difference |
|
|
5.7m3/h (200cfh) |
50bar(725psi) |
49bar(710psi)
|
|
|
|
Vacuum compressor |
Theoretical vacuum quantity |
Final vacuum degree |
|
|
|
5.2 m3/h(184 cfh) |
﹤50mbar (﹤37.5mm Hg) |
|
|
|
|
paint |
orange-yellowRAL2004
|
|
|
|
|
Electrical connectors |
Voltage plug |
32A-connecting cable5*6mm2
|
|
|
Product Configuration
|
|
SF6 gasRecycling device configuration |
|
||
|
l compressorTM5.0 |
1Taiwan |
|
||
|
l Vacuum compressor |
1Taiwan |
|
||
|
l vacuum pump |
1Taiwan |
|
||
|
l Automatic device with automatic process control |
1Taiwan |
|
||
|
l evaporator |
1a |
|
||
|
l Dry filter |
1a |
|
||
|
l SF6Steel cylinder scale |
1a |
|
||
|
Attachment configuration |
|
|
||
|
l vacuum pump25m³/hThe exhaust filter |
1set |
|
||
|
l vacuum pump40m³/hThe exhaust filter |
1a |
|
||
|
l Two axle chassis and pneumatic tires |
a set |
|
||
|
l Recycling vehicle and chassis packaging for two axles |
a set |
|
||
|
l rubber hoseDN20/5Meter long, with tongue joints at both endsDN20 |
a |
|
||
|
l rubber hoseDN20/7Meter long, with tongue joints at both endsDN20 |
a |
|
||
|
l rubber hoseDN20/10Meter long, with tongue joints at both endsDN20 |
a |
|
||
Service Guarantee

l Provide on-site training guidance and conduct on-site demonstration operations.
l Provide detailed Chinese manuals and user guidance.
l One year free warranty, lifetime spare parts support and maintenance.
l User profile information management, customer service department provides bi annual follow-up and tracking services.
l hotline365Answer user inquiries 24/7.