Purpose:
Laboratory testing of chloride ion content to control and prevent premature corrosion of steel bars, express testing of water-soluble chloride ion content in inorganic materials such as concrete, sand and gravel, cement, etc. Combined with the chloride ion diffusion coefficient in concrete, the service life of concrete structures and the corrosion life of steel bars can be predicted.
Execution standards:
◆Concrete Test Specification for Water Transport Engineering:JTJ270-98
◆Test Method for Uniformity of Concrete Admixtures:GB/T8077-2000
◆Code for Durability Design of Concrete Structures:GB/T50476-2008
Product Features:
◆ It can measure the water-soluble chloride ion content of concrete mixtures, hard concrete, sand and gravel, additives, water and other materials, and directly output the results in units of molar concentration and mass percentage;
◆ Built in standard formula, directly calculate the chloride ion content of concrete mixture;
◆ Unique anti ion interference agent, capable of removing the oxidation effects of cyanide and ammonia ions, as well as the chelation effects of metal ions such as manganese and lead;
◆ Large screen LCD direct display, instant printing, one click completion of testing, easy to use and operate;
◆ Lightweight, compact body, easy for users to carry, suitable for on-site inspection;
◆ Optional micro printer, which can print immediately even without using a computer;
◆ Original upper computer software that can directly export data, test reports, etc;
◆ Large capacity data storage, capable of storing100Continuous recording of data, convenient for users to view, and safe and reliable;
Technical parameters and product configuration:
Technical parameters: |
Main product configuration: |
|
◆ Power supply:AC220V 50Hz Measurement range of chloride ion concentration:10-5~10-1Mol/L ◆PHRange:2~10PH ◆ Temperature range:0~40℃ (Recommended usage scope10~30℃) Response time: ≤2min Resolution: ≤2mV ◆ Input impedance: ≥1×1012Ω Test accuracy: ≤10% Output method: Print output Voltage accuracy: < ±1mA Instrument accuracy: <1%
|
◆RJLU-APortable rapid content analyzer:1tower Chloride ion electrode:1root ◆ Reference electrode for calomel:1root ◆ Water soluble chloride ion standard solution0.1Mol/L:1bottle(100mL) ◆ Water soluble chloride ion standard solution0.01Mol/L:1bottle(100mL) ◆ Water soluble chloride ion standard solution0.001Mol/L:1bottle(100mL) ◆ Water soluble chloride ion standard solution0.0001Mol/L:1bottle(100mL) ◆ Reference electrode filling solution of calomel:1bottle(30mL) ◆ Nanfu Battery:5joint ◆ External micro printer:1Taiwan) ◆ Printer charger:1individual ◆ Connect the printer data cable:1strip ◆ Printing paper:1Roll (gift) |