English

Chongqing Shangli Instrument Equipment Co., Ltd
Home>Products>RVLM instrument for rapid detection of microorganisms
RVLM instrument for rapid detection of microorganisms
The RVLM rapid detection instrument for microorganisms adopts MBSTM (Micro Biology SurveyTM) detection technology, which is a microbial detection inst
Product details

RVLM®Instruments for rapid detection of microorganismsDirect injection analysis, no pre-treatment required, and no sterilization treatment required after testing is completed.

RVLM®The instrument for rapid detection of microorganisms has independent control of each detection position and can simultaneously perform different microbial tests. After the testing is completed, the next testing can start immediately without waiting for other samples in the batch to complete the testing. Slot style design greatly enhances the scalability of the instrument, allowing for simultaneous detection of hundreds of samples by simply connecting multiple instruments in parallel.
The MBS microbiological testing method has been included as an alternative microbiological testing method by the European Union and has become a US peacekeeping, field, and military supply material, while also being widely used.

Testing Scope
Total bacterial count, coliforms/Escherichia coli/Escherichia coli O157, O111, O104, EHEC, Staphylococcus aureus, Salmonella, Listeria monocytogenes, Pseudomonas aeruginosa, Pseudomonas aeruginosa, Enterobacteriaceae, Enterococcus, yeast, Aspergillus fungi, etc

Scope of application
Hygiene control:
Food: meat, fruits and vegetables, dairy products, staple foods, seasonings, hot and cold dishes, semi processed foods, and beverages, etc
Water quality: domestic drinking water, natural water sources
Surface: Clean table, tableware, utensil surface
Other: pharmaceuticals, cosmetics, pulp, etc
HACCP critical point diagnosis
Emergency control:
Suitable for rapid microbial safety testing at disaster sites, on-site, sampling, large-scale conferences, etc

RVLM®parameter
Detection accuracy: 1 colony
Range: 1~9.999 × 107 CFU/ml or g
The specificity is as high as 99.999%, and there are no false positives
Sample size: A single unit can detect 8 samples; Up to 8 instruments can be connected in parallel, allowing for simultaneous detection of 64 samples
Solid, liquid, and surface samples do not require pre-treatment or post-treatment procedures
The accuracy of the test results is not affected by factors such as pH value, color, and turbidity
Equipped with automatic incubation and temperature control functions
The deviation between the detection results and the detection method is within ± 0.5log CFU/ml, and the compliance rate of the sample detection is higher than 85%
The test results can be stored and there is no legal person to modify them
Full Chinese operation interface and Chinese software
When the total bacterial concentration is 104 CFU/g, the detection time should not exceed 8 hours; When the concentration of coliform bacteria is 106 CFU/g, the detection time should not exceed 4 hours; Single strain initial screening, fast no more than 2 hours
Can be customized according to national standards to shorten testing time
Net weight of the instrument: 2.5kg
Instrument size (LxH): 30cmx20cmx10cm
Power specifications: 90~240V, 50~60Hz

RVLM®Features:
1. High precision: Using MBS technology, the detection accuracy can reach up to 1 colony, with a specificity of 99.999%
2. Rapid detection: The detection speed is 2-20 times faster than traditional detection methods
3. Easy to operate: Three steps to complete the test, no need for professional testing personnel, no need for sterile environment, no need for pre-treatment procedures
4. Fully automatic analysis: automatically stops at the end of detection, and can achieve compatibility with different computer operating environments and databases

Three simple steps to obtain accurate quantitative detection results
Step 1: Directly add 1g (solid)/1ml (liquid) sample
No pre-treatment is required for solid, liquid, or surface samples
Step 2: Shake the sample evenly
Step 3: The detector automatically reads the results

Save and upload results
--Automatic stop upon completion of detection
--Directly provide quantitative analysis results, and the results are not subject to legal modification
--Data can be stored and transmitted
--All detection traces can be tracked and queried through the built-in chip

RVLM ® Composition of Type System
Test reagent
RVLM®
Quantitative analysis software
computer

Domestic and international certification
Instrument CE certification
ISO laboratory certification
AOAC certification enters mid-term experiment
National standard comparison experiment completed
SNT industry standard verification stage
National Light Industry Food Quality Supervision and Testing
Verification Report
Shenyang Food and Drug Administration

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!