QDX single-phase submersible pump
QDX single-phase submersible pump is a new generation product developed based on the characteristics of Chinese users. It has a wide high-efficiency r
Product details

product overview
QDX single-phase submersible pump is a new generation product developed based on the characteristics of Chinese users. It has a wide high-efficiency range, strong passing capacity, long service life, convenient arrangement, and control functions. Especially in terms of full head performance and sealing technology, it has its own characteristics.

Product Features
This product has a novel design, compact structure, and is light, small, and easy to move; External capacitors make maintenance very convenient; Equipped with an internal electrical protection switch, it is durable, safe and reliable.

application
Suitable for small-scale irrigation or water lifting in agriculture, industrial and mining enterprises, construction sites, villas, especially households.

Model Meaning
For example: QDX1.5-16-0.37
QDX single-phase plastic submersible pump
1.5- Flow rate (m3/n)
16 Head (m)
0.37- Motor power (kw)


name
model
Rated flow rate
(m3/n)
rated head
(m)
voltage
(V)
power
(KW)
rotational speed
(r/min)
Pipe diameter
(mm) Inch Inch
QDX
type
one
each other
go underwater
water
pump
QDX1.5-16-0.37 1.5 16 220 0.37 2860 25 1
QDX3-20-0.55 3 20 220 0.55 2860 25 1
QDX10-10-0.55 10 10 220 0.55 2860 40 1.5
QDX15-7-0.55 15 7 220 0.55 2860 50 2
QDX1.5-32-0.75 1.5 32 220 0.75 2860 25 1
QDX7-18-0.75 7 18 220 1.75 2860 40 1.5
QDX10-16-0.75 10 16 220 0.75 2860 50 2
QDX15-10-0.75 15 10 220 0.75 2860 63 2.5
QDX25-9-1.1 25 9 220 1.1 2860 63 2.5
QDX40-6-1.1 40 6 220 1.1 2860 75 3
QDX40-6-1.1T 40 6 220 1.1 2860 75 3
QDX25-12-1.5T 25 12 220 1.5 2860 63 2.5
QDX40-9-1.5T 40 9 220 1.5 2860 75 3
QX
type
three
each other
go underwater
water
pump
QX3-20-0.55 3 20 380 0.55 3000 25 1
QX10-10-0.55 10 10 380 0.55 3000 40 1.5
QX15-7-0.55 15 7 380 0.55 3000 50 2
QX1.5-32-0.75 1.5 32 380 0.75 3000 25 1
QX7-18-0.75 7 18 380 0.75 3000 40 1.5
QX10-16-0.75 10 16 380 0.75 3000 50 2
QX15-10-0.75 15 10 380 0.75 3000 63 2.5
QX25-9-1.1 25 9 380 1.1 3000 63 2.5
QX40-6-1.1 40 6 380 1.1 3000 75 3
QX40-6-1.1T 40 6 380 1.1 3000 75 3
QX25-12-1.5T 25 12 380 1.5 3000 63 2.5
QX40-9-1.5T 40 9 380 1.5 3000 75 3
QX65-8-2.2 65 8 380 2.2 3000 100 4
QX8-28-1.1T 8 28 380 1.1 3000 40 1.5
QX15-15-1.1T 15 15 380 1.1 3000 50 2
QX8-35-2.2T 8 35 380 2.2 3000 50 2
QX9-22-2.2T 9 22 380 2.2 3000 50 2
QX10-35-2.2T 10 35 380 2.2 3000 50 2
QX12-45-3T 12 45 380 3.0 3000 50 2
QX12-60-4T 12 60 380 4.0 3000 50 2
QX12-70-5.5T 12 70 380 5.5 3000 50 2
QX20-60/2-7.5T 20 60 380 7.5 3000 50 2
QDX
type
new
type
joint
ability
go underwater
water
electricity
pump
QDX6-12-0.4 6 12 220 0.4 2860 25/40 1/1.5
QDX3-24-0.55 3 24 220 0.55 2860 25 1
QDX3-30-0.75 3 30 220 0.75 2860 25 1
QDX10-15-0.75T 10 15 220 0.75 2860 50 1.5/2
QD10-15-0.75T 10 15 220/380 0.75 3000 50 1.5/2
QDX7.8-15-0.75T 7.8 15 220/380 0.75 2800/3000 50 1.5/2
QDX10-23-1.1T 10 23 220 1.1 2860 50 1.5/2
QDX10-23-1.1T 10 23 220 1.1 3000 50 1.5/2
WQDK10-18-1.1T 10 18 220 1.1 2860 50 1.5/2
WDK10-18-1.1T 10 18 380 1.1 3800 50 1.5/2
QDX
type
joint
ability
electricity
press
rise
move
go underwater
water
electricity
pump
QDX1.5-32-0.758 1.5 32 220 0.75 2860 25 1
QDX10-16-0.75 10 16 220 1.1 2860 50 2
QDX1.5-38-1.1T 1.5 38 220 1.1 2860 25 1
QDX10-20-1.1T 10 20 220 1.1 2860 50 2
QDX15-15-1.1T 15 15 220 1.1 2860 63 2.5
QDX30-9-1.1T 30 9 220 1.1 2860 75 3
QDX15-19-1.5T 15 18 220 1.5 2860 63 2.5
QDX40-9-1.5T 40 9 220 1.5 2860 75 3
QDX65-7-2.2T 65 7 220 2.2 2860 100 4


Troubleshooting:

Fault phenomenon

Cause analysis

Exclusion method

Insufficient traffic

Or no water will come out

1. Impeller rotation error

2. Is the valve open and intact

3. The pipeline is blocked

4. Low speed

5. Head too high

6. The density of the pumping medium is relatively high

7. High viscosity of the medium

8. Damaged sealing ring (at the mouth ring)

1. Adjust the rotation direction of the impeller

2. Check, repair, and eliminate

3. Clean up debris

4. Check electrical equipment and circuits

5. Change the pump or reduce the head

6. Dilute with water to reduce concentration

7. Reduce viscosity

8. Replace

Unstable operation

1. Unbalanced impeller

2. Bearing damage

1. Send to the manufacturer for replacement or calibration

2. Replace the impeller

The pump cannot start

1. Lack of phase

2. Impeller stuck

3. Winding, connector or cable open circuit

4. Stator winding burnt out

5. Electrical control malfunction

1. Check the circuit for repair

2. Remove debris

3. Use an ohmmeter to check and repair

4. Repair and replace the winding

5. Repair or replace

Excessive current

1. Low working voltage

2. Pipeline and impeller blockage

3. Transporting liquids that have passed or have high viscosity

4. Using a lift that is too high

1. Adjust the working voltage

2. Clean the pipeline and replace the winding

3. Change density or viscosity

4. Reduce traffic and increase traffic

Low insulation resistance

1. Leakage at the power supply terminal of the cable

2. Cable damage

3. Mechanical seal wear leads to leakage

4. Failure of each O-ring seal

5. The casing is corroded by the medium and leaks water

1. Tighten the compression nut

2. Replace

3. Replace

4. Replace

5. Repair