product overview
QDX single-phase submersible pump is a new generation product developed based on the characteristics of Chinese users. It has a wide high-efficiency range, strong passing capacity, long service life, convenient arrangement, and control functions. Especially in terms of full head performance and sealing technology, it has its own characteristics.
Product Features
This product has a novel design, compact structure, and is light, small, and easy to move; External capacitors make maintenance very convenient; Equipped with an internal electrical protection switch, it is durable, safe and reliable.
application
Suitable for small-scale irrigation or water lifting in agriculture, industrial and mining enterprises, construction sites, villas, especially households.
Model Meaning
For example: QDX1.5-16-0.37
QDX single-phase plastic submersible pump
1.5- Flow rate (m3/n)
16 Head (m)
0.37- Motor power (kw)
name |
model |
Rated flow rate (m3/n) |
rated head (m) |
voltage (V) |
power (KW) |
rotational speed (r/min) |
Pipe diameter |
|
(mm) | Inch Inch | |||||||
QDX type one each other go underwater water pump |
QDX1.5-16-0.37 | 1.5 | 16 | 220 | 0.37 | 2860 | 25 | 1 |
QDX3-20-0.55 | 3 | 20 | 220 | 0.55 | 2860 | 25 | 1 | |
QDX10-10-0.55 | 10 | 10 | 220 | 0.55 | 2860 | 40 | 1.5 | |
QDX15-7-0.55 | 15 | 7 | 220 | 0.55 | 2860 | 50 | 2 | |
QDX1.5-32-0.75 | 1.5 | 32 | 220 | 0.75 | 2860 | 25 | 1 | |
QDX7-18-0.75 | 7 | 18 | 220 | 1.75 | 2860 | 40 | 1.5 | |
QDX10-16-0.75 | 10 | 16 | 220 | 0.75 | 2860 | 50 | 2 | |
QDX15-10-0.75 | 15 | 10 | 220 | 0.75 | 2860 | 63 | 2.5 | |
QDX25-9-1.1 | 25 | 9 | 220 | 1.1 | 2860 | 63 | 2.5 | |
QDX40-6-1.1 | 40 | 6 | 220 | 1.1 | 2860 | 75 | 3 | |
QDX40-6-1.1T | 40 | 6 | 220 | 1.1 | 2860 | 75 | 3 | |
QDX25-12-1.5T | 25 | 12 | 220 | 1.5 | 2860 | 63 | 2.5 | |
QDX40-9-1.5T | 40 | 9 | 220 | 1.5 | 2860 | 75 | 3 | |
QX type three each other go underwater water pump |
QX3-20-0.55 | 3 | 20 | 380 | 0.55 | 3000 | 25 | 1 |
QX10-10-0.55 | 10 | 10 | 380 | 0.55 | 3000 | 40 | 1.5 | |
QX15-7-0.55 | 15 | 7 | 380 | 0.55 | 3000 | 50 | 2 | |
QX1.5-32-0.75 | 1.5 | 32 | 380 | 0.75 | 3000 | 25 | 1 | |
QX7-18-0.75 | 7 | 18 | 380 | 0.75 | 3000 | 40 | 1.5 | |
QX10-16-0.75 | 10 | 16 | 380 | 0.75 | 3000 | 50 | 2 | |
QX15-10-0.75 | 15 | 10 | 380 | 0.75 | 3000 | 63 | 2.5 | |
QX25-9-1.1 | 25 | 9 | 380 | 1.1 | 3000 | 63 | 2.5 | |
QX40-6-1.1 | 40 | 6 | 380 | 1.1 | 3000 | 75 | 3 | |
QX40-6-1.1T | 40 | 6 | 380 | 1.1 | 3000 | 75 | 3 | |
QX25-12-1.5T | 25 | 12 | 380 | 1.5 | 3000 | 63 | 2.5 | |
QX40-9-1.5T | 40 | 9 | 380 | 1.5 | 3000 | 75 | 3 | |
QX65-8-2.2 | 65 | 8 | 380 | 2.2 | 3000 | 100 | 4 | |
QX8-28-1.1T | 8 | 28 | 380 | 1.1 | 3000 | 40 | 1.5 | |
QX15-15-1.1T | 15 | 15 | 380 | 1.1 | 3000 | 50 | 2 | |
QX8-35-2.2T | 8 | 35 | 380 | 2.2 | 3000 | 50 | 2 | |
QX9-22-2.2T | 9 | 22 | 380 | 2.2 | 3000 | 50 | 2 | |
QX10-35-2.2T | 10 | 35 | 380 | 2.2 | 3000 | 50 | 2 | |
QX12-45-3T | 12 | 45 | 380 | 3.0 | 3000 | 50 | 2 | |
QX12-60-4T | 12 | 60 | 380 | 4.0 | 3000 | 50 | 2 | |
QX12-70-5.5T | 12 | 70 | 380 | 5.5 | 3000 | 50 | 2 | |
QX20-60/2-7.5T | 20 | 60 | 380 | 7.5 | 3000 | 50 | 2 | |
QDX type new type joint ability go underwater water electricity pump |
QDX6-12-0.4 | 6 | 12 | 220 | 0.4 | 2860 | 25/40 | 1/1.5 |
QDX3-24-0.55 | 3 | 24 | 220 | 0.55 | 2860 | 25 | 1 | |
QDX3-30-0.75 | 3 | 30 | 220 | 0.75 | 2860 | 25 | 1 | |
QDX10-15-0.75T | 10 | 15 | 220 | 0.75 | 2860 | 50 | 1.5/2 | |
QD10-15-0.75T | 10 | 15 | 220/380 | 0.75 | 3000 | 50 | 1.5/2 | |
QDX7.8-15-0.75T | 7.8 | 15 | 220/380 | 0.75 | 2800/3000 | 50 | 1.5/2 | |
QDX10-23-1.1T | 10 | 23 | 220 | 1.1 | 2860 | 50 | 1.5/2 | |
QDX10-23-1.1T | 10 | 23 | 220 | 1.1 | 3000 | 50 | 1.5/2 | |
WQDK10-18-1.1T | 10 | 18 | 220 | 1.1 | 2860 | 50 | 1.5/2 | |
WDK10-18-1.1T | 10 | 18 | 380 | 1.1 | 3800 | 50 | 1.5/2 | |
QDX type joint ability electricity press rise move go underwater water electricity pump |
QDX1.5-32-0.758 | 1.5 | 32 | 220 | 0.75 | 2860 | 25 | 1 |
QDX10-16-0.75 | 10 | 16 | 220 | 1.1 | 2860 | 50 | 2 | |
QDX1.5-38-1.1T | 1.5 | 38 | 220 | 1.1 | 2860 | 25 | 1 | |
QDX10-20-1.1T | 10 | 20 | 220 | 1.1 | 2860 | 50 | 2 | |
QDX15-15-1.1T | 15 | 15 | 220 | 1.1 | 2860 | 63 | 2.5 | |
QDX30-9-1.1T | 30 | 9 | 220 | 1.1 | 2860 | 75 | 3 | |
QDX15-19-1.5T | 15 | 18 | 220 | 1.5 | 2860 | 63 | 2.5 | |
QDX40-9-1.5T | 40 | 9 | 220 | 1.5 | 2860 | 75 | 3 | |
QDX65-7-2.2T | 65 | 7 | 220 | 2.2 | 2860 | 100 | 4 |
Troubleshooting:
Fault phenomenon |
Cause analysis |
Exclusion method |
Insufficient traffic
Or no water will come out |
1. Impeller rotation error 2. Is the valve open and intact 3. The pipeline is blocked 4. Low speed 5. Head too high 6. The density of the pumping medium is relatively high 7. High viscosity of the medium 8. Damaged sealing ring (at the mouth ring) |
1. Adjust the rotation direction of the impeller 2. Check, repair, and eliminate 3. Clean up debris 4. Check electrical equipment and circuits 5. Change the pump or reduce the head 6. Dilute with water to reduce concentration 7. Reduce viscosity 8. Replace |
Unstable operation |
1. Unbalanced impeller 2. Bearing damage |
1. Send to the manufacturer for replacement or calibration 2. Replace the impeller |
The pump cannot start |
1. Lack of phase 2. Impeller stuck 3. Winding, connector or cable open circuit 4. Stator winding burnt out 5. Electrical control malfunction |
1. Check the circuit for repair 2. Remove debris 3. Use an ohmmeter to check and repair 4. Repair and replace the winding 5. Repair or replace |
Excessive current |
1. Low working voltage 2. Pipeline and impeller blockage 3. Transporting liquids that have passed or have high viscosity 4. Using a lift that is too high |
1. Adjust the working voltage 2. Clean the pipeline and replace the winding 3. Change density or viscosity 4. Reduce traffic and increase traffic |
Low insulation resistance |
1. Leakage at the power supply terminal of the cable 2. Cable damage 3. Mechanical seal wear leads to leakage 4. Failure of each O-ring seal 5. The casing is corroded by the medium and leaks water |
1. Tighten the compression nut 2. Replace 3. Replace 4. Replace 5. Repair |