Duzhi Instrument (Shanghai) Co., Ltd
Home>Products>PosiTector6000 Integrated/Conventional Range Coating Thickness Gauge
PosiTector6000 Integrated/Conventional Range Coating Thickness Gauge
The PosiTector6000 integrated/conventional range coating thickness gauge includes both integrated and split type instruments, consisting of a main bod
Product details

Details of PosiTector6000 Integrated/Conventional Range Coating Thickness Gauge:

PosiTector6000 Integrated/Conventional Range Coating Thickness Gauge

The PosiTector 6000 includes both integrated and split type instruments, consisting of a main body and a probe. There are multiple interchangeable probes to choose from. Used for measuring non-magnetic coatings on magnetic substrates such as steel, as well as insulation layers on non-ferrous metals such as copper, aluminum, and austenitic stainless steel. Integrated design, convenient for one handed operation. There are also right angle probes used for measuring in areas with relatively low clearance height. With its small probe tip and thin piece measurement accuracy, it is highly suitable for measuring small parts, hard to reach areas, or near edge areas. Alignment measurements can also be performed on small, flat, or curved components. Sealed constant pressure stainless steel probe, completely waterproof, suitable for underwater use. The dual phase coating system uses a combination of two anti-corrosion systems, typically used to measure the thickness of paint or powder coatings (hot-dip, electroplating, or zinc spray metallization) applied to galvanized steel plates. It can measure the total thickness of the zinc layer and coating separately at once

Characteristics of Coating Thickness Gauge:

simple

-Quick measurement mode -60+measurements per minute
-Direct measurement - meets most applications without calibration
-Enhanced one handed menu operation
-Light prompt: facilitates the determination of measurement results obtained in noisy environments
-The reset function can quickly restore the thickness gauge to its factory state

durable

-Acid proof, oil proof, waterproof, solvent proof, dustproof
-Wear resistant probe
-Anti impact rubber protective cover

accurate

-Each instrument has a calibration certificate traceable to NIST or PTB standards
-Built in temperature compensation to ensure measurement accuracy
-High resolution mode can improve display resolution
-Compliant with US and international standards, including ISO and ASTM standards

>Two types of host function descriptions:

Type 1- Standard Host

(Standard)

-Having all the advantages listed above
-Can store 250 pieces of data

Type 3- Advanced Host

(Advanced)

-Can store 1000 sets of 100000 data in total
-Real time charts, image prompts, and group annotations
-3x speed scanning mode
Normal - Read readings continuously without lifting the probe
New statistics - Obtain continuous readings during scanning and record the mean, standard deviation, minimum/maximum thickness, and number of readings
New limited count average - user-defined measurement times, thickness gauge displays and records the average reading.
-Multiple calibration settings that can store different substrate conditions
-SSPC PA2 function determines whether the coating thickness on a large area meets the minimum/maximum value specified by the user
-PSPC 90/10 determines whether it meets the performance standards of IMO (International Maritime Organization) protective coatings
-Add comments and change group names using the on-screen QWERTY keyboard
-WiFi and PosiSoft. * * Wireless synchronization and software download
-Bluetooth 4.0 transfers data to the PosiTector app or optional portable printing. BLE API can be integrated into third-party software
-The data of other probes stored on the host, such as thickness, salinity, roughness, hardness, etc., are all in different groups

Smartlink wireless host -Through the app, connect the probe wirelessly with smart devices, turning phones and tablets into a virtual host

Probe (more detailed probe information)

-All probes are detachable
-F-type probe - electromagnetic. Non magnetic coatings used on magnetic substrates such as steel, such as paint, plastic, enamel, chromium, zinc, etc
-N-type probe - eddy current. Used for all insulation layers on non-ferrous metals (such as copper, aluminum, austenitic stainless steel), such as anodized film, paint, etc
-FN type probe - a dual-purpose probe that can automatically switch measurements on magnetic and non-magnetic substrates
-The surface of the FXS probe is made of zirconia toughened alumina, which is suitable for workpieces with rough surfaces and can withstand high temperatures up to 250 ℃
-The surface of FHXS probe is made of alumina and is equipped with armored probe wire, which can withstand high temperature of 250 ℃
-The FNDS probe is specifically designed to measure the coating on galvanized sheets, and can simultaneously measure the thickness of the zinc layer and the coating separately
-FNGS probe, capable of measuring non-conductive coatings on magnetic substrates and non-ferrous metals

PosiTector 6000

Model Selection

model host probe range precision

6000F1/6000F3

Standard/Advanced Type

F (F-type/integrated/conventional range probe) 0~1500μm

At 0-50 μ m ± (1 μ m+1%)

>At 50 μ m ± (2 μ m+1%)

6000N1/6000N3

Standard/Advanced Type

N (N-type/integrated/conventional range probe)

6000FN1/6000FN3

Standard/Advanced Type

FN (FN dual-purpose/integrated/conventional range probe)

6000FS1/6000FS3

Standard/Advanced Type

FS (F-type/conventional range probe) 0~1500μm

At 0-50 μ m ± (1 μ m+1%)

>At 50 μ m ± (2 μ m+1%)

6000NS1/6000NS3

Standard/Advanced Type

NS (N-type/conventional range probe)

6000FNS1/6000FNS3

Standard/Advanced Type

FNS (FN dual-purpose/conventional range probe)

6000FRS1/6000FRS3

Standard/Advanced Type

FRS (F-type/conventional range/right angle probe) 0~1500μm

At 0-50 μ m ± (1 μ m+1%)

>At 50 μ m ± (2 μ m+1%)

6000NRS1/6000NRS3

Standard/Advanced Type

NRS (N-type/conventional range/right angle probe)

6000FNRS1/6000FNRS3

Standard/Advanced Type

FNRS (FN dual-purpose/conventional range/right angle probe)

6000FNDS1/6000FNDS3

Standard/Advanced Type

FNDS (FN type/used for steel zinc paint measurement)

0~1500μm

Zinc layer>13 μ m

Measurement of coating: ± (1 μ m+1%) at 0-50 μ m

>At 50 μ m ± (2 μ m+1%)

Measurement of zinc layer: ± (2 μ m+1%) at 13-50 μ m

>At 50 μ m ± (4 μ m+1%)

6000FXS1/6000FXS3

Standard/Advanced Type

FXS (F-type/conventional/wear-resistant/resistant to 250 degrees high temperature)

Xtreme ™ Probe)

0~2000μm

At 0-50 μ m ± (1 μ m+1%)

>At 50 μ m ± (2 μ m+1%)

6000F0S1/6000F0S3

Standard/Advanced Type

F0S (F-type/miniature probe/0 °) 0~1150μm

At 0~100 μ m ± (0.5 μ m+1%)

>At 100 μ m ± (2 μ m+3%)

6000F45S1/6000F45S3

Standard/Advanced Type

F45S (F-type/miniature probe/45 °) 0~1150μm

At 0~100 μ m ± (0.5 μ m+1%)

>At 100 μ m ± (2 μ m+3%)

6000F90S1/6000F90S3

Standard/Advanced Type

F90S (F-type/miniature probe/90 °) 0~1150μm

At 0~100 μ m ± (0.5 μ m+1%)

>At 100 μ m ± (2 μ m+3%)

6000F90ES1/6000F90ES3

Standard/Advanced Type

F90ES (F-type/miniature probe/90 °/350mm extension rod) 0~1150μm

At 0~100 μ m ± (0.5 μ m+1%)

>At 100 μ m ± (2 μ m+3%)

6000NAS1/6000NAS3

Standard/Advanced Type

NAS (N-type/measurement thin coating, such as aluminum based oxide film) 0~625μm

At 0~100 μ m ± (0.5 μ m+1%)

>At 100 μ m ± (2 μ m+3%)

6000N0S1/6000N0S3

Standard/Advanced Type

N0S (N-type/miniature probe/0 °) 0~625μm

At 0~100 μ m ± (0.5 μ m+1%)

>At 100 μ m ± (2 μ m+3%)

6000N45S1/6000N45S3

Standard/Advanced Type

N45S (N-type/miniature probe/45 °) 0~625μm

At 0~100 μ m ± (0.5 μ m+1%)

>At 100 μ m ± (2 μ m+3%)

6000N90S1/6000N90S3

Standard/Advanced Type

N90S (N-type/miniature probe/90 °) 0~625μm

At 0~100 μ m ± (0.5 μ m+1%)

>At 100 μ m ± (2 μ m+3%)

6000FT1/6000FT3

Standard/Advanced Type

FT (F-type/integrated/medium range probe/) 0~6mm

± (0.01mm+1%) at 0-2.5mm

>At 2.5mm ± (0.01mm+3%)

6000FTS1/6000FTS3

Standard/Advanced Type

FTS (F-type/medium range probe) 0~6mm

± (0.01mm+1%) at 0-2.5mm

>At 2.5mm ± (0.01mm+3%)

6000FNTS1/6000FNTS3

Standard/Advanced Type

FNTS (FN dual-purpose/medium range probe) 0~6mm

± (0.01mm+1%) at 0-2.5mm

>At 2.5mm ± (0.01mm+3%)

6000FTRS1/6000FTRS3

Standard/Advanced Type

FTRS (F-type/medium range/right angle probe) 0~6mm

± (0.01mm+1%) at 0-2.5mm

>At 2.5mm ± (0.01mm+3%)

6000FHXS1/6000FHXS3

Standard/Advanced Type

FHXS (F-type/large range/high temperature resistance of 250 degrees Xtreme) ™ Probe)

0~10mm ±(2μm+3%)

6000FKS1/6000FKS3

Standard/Advanced Type

FKS (F-type/large range probe) 0~13mm ±(0.02mm+3%)

6000NKS1/6000NKS3

Standard/Advanced Type

NKS (N-type/Large Range Probe)

6000FJS1/6000FJS3

Standard/Advanced Type

FJS (F-type/ultra large range probe) 0~25mm ±(0.2mm+3%)

6000FLS1/6000FLS3

Standard/Advanced Type

FLS (F-type/ultra large range probe) 0~38mm ±(0.2mm+3%)

6000FNGS1/6000FNGS3

Standard/Advanced Type

FNGS (Ultra Large Range Probe/Non Conductive Coating on Iron and Non Iron Metals)

0~63.5mm ±(0.2mm+3%)