Details of PosiTector6000 Integrated/Conventional Range Coating Thickness Gauge:
PosiTector6000 Integrated/Conventional Range Coating Thickness Gauge
The PosiTector 6000 includes both integrated and split type instruments, consisting of a main body and a probe. There are multiple interchangeable probes to choose from. Used for measuring non-magnetic coatings on magnetic substrates such as steel, as well as insulation layers on non-ferrous metals such as copper, aluminum, and austenitic stainless steel. Integrated design, convenient for one handed operation. There are also right angle probes used for measuring in areas with relatively low clearance height. With its small probe tip and thin piece measurement accuracy, it is highly suitable for measuring small parts, hard to reach areas, or near edge areas. Alignment measurements can also be performed on small, flat, or curved components. Sealed constant pressure stainless steel probe, completely waterproof, suitable for underwater use. The dual phase coating system uses a combination of two anti-corrosion systems, typically used to measure the thickness of paint or powder coatings (hot-dip, electroplating, or zinc spray metallization) applied to galvanized steel plates. It can measure the total thickness of the zinc layer and coating separately at once
Characteristics of Coating Thickness Gauge:
|
>Two types of host function descriptions:
|
Type 1- Standard Host (Standard) |
-Having all the advantages listed above -Can store 250 pieces of data |
|
Type 3- Advanced Host (Advanced) |
-Can store 1000 sets of 100000 data in total |
| Smartlink wireless host | -Through the app, connect the probe wirelessly with smart devices, turning phones and tablets into a virtual host |

Probe (more detailed probe information) | |
|

Model Selection
| model | host | probe | range | precision | |
6000F1/6000F3 |
Standard/Advanced Type |
F (F-type/integrated/conventional range probe) | 0~1500μm |
At 0-50 μ m ± (1 μ m+1%) >At 50 μ m ± (2 μ m+1%) |
|
6000N1/6000N3 |
Standard/Advanced Type |
N (N-type/integrated/conventional range probe) | |||
6000FN1/6000FN3 |
Standard/Advanced Type |
FN (FN dual-purpose/integrated/conventional range probe) | |||
6000FS1/6000FS3 |
Standard/Advanced Type |
FS (F-type/conventional range probe) | 0~1500μm |
At 0-50 μ m ± (1 μ m+1%) >At 50 μ m ± (2 μ m+1%) |
|
6000NS1/6000NS3 |
Standard/Advanced Type |
NS (N-type/conventional range probe) | |||
6000FNS1/6000FNS3 |
Standard/Advanced Type |
FNS (FN dual-purpose/conventional range probe) | |||
6000FRS1/6000FRS3 |
Standard/Advanced Type |
FRS (F-type/conventional range/right angle probe) | 0~1500μm |
At 0-50 μ m ± (1 μ m+1%) >At 50 μ m ± (2 μ m+1%) |
|
6000NRS1/6000NRS3 |
Standard/Advanced Type |
NRS (N-type/conventional range/right angle probe) | |||
6000FNRS1/6000FNRS3 |
Standard/Advanced Type |
FNRS (FN dual-purpose/conventional range/right angle probe) | |||
6000FNDS1/6000FNDS3 |
Standard/Advanced Type |
FNDS (FN type/used for steel zinc paint measurement) |
0~1500μm Zinc layer>13 μ m |
Measurement of coating: ± (1 μ m+1%) at 0-50 μ m >At 50 μ m ± (2 μ m+1%) Measurement of zinc layer: ± (2 μ m+1%) at 13-50 μ m >At 50 μ m ± (4 μ m+1%) |
|
6000FXS1/6000FXS3 |
Standard/Advanced Type |
FXS (F-type/conventional/wear-resistant/resistant to 250 degrees high temperature) Xtreme ™ Probe) |
0~2000μm |
At 0-50 μ m ± (1 μ m+1%) >At 50 μ m ± (2 μ m+1%) |
|
6000F0S1/6000F0S3 |
Standard/Advanced Type |
F0S (F-type/miniature probe/0 °) | 0~1150μm |
At 0~100 μ m ± (0.5 μ m+1%) >At 100 μ m ± (2 μ m+3%) |
|
6000F45S1/6000F45S3 |
Standard/Advanced Type |
F45S (F-type/miniature probe/45 °) | 0~1150μm |
At 0~100 μ m ± (0.5 μ m+1%) >At 100 μ m ± (2 μ m+3%) |
|
6000F90S1/6000F90S3 |
Standard/Advanced Type |
F90S (F-type/miniature probe/90 °) | 0~1150μm |
At 0~100 μ m ± (0.5 μ m+1%) >At 100 μ m ± (2 μ m+3%) |
|
6000F90ES1/6000F90ES3 |
Standard/Advanced Type |
F90ES (F-type/miniature probe/90 °/350mm extension rod) | 0~1150μm |
At 0~100 μ m ± (0.5 μ m+1%) >At 100 μ m ± (2 μ m+3%) |
|
6000NAS1/6000NAS3 |
Standard/Advanced Type |
NAS (N-type/measurement thin coating, such as aluminum based oxide film) | 0~625μm |
At 0~100 μ m ± (0.5 μ m+1%) >At 100 μ m ± (2 μ m+3%) |
|
6000N0S1/6000N0S3 |
Standard/Advanced Type |
N0S (N-type/miniature probe/0 °) | 0~625μm |
At 0~100 μ m ± (0.5 μ m+1%) >At 100 μ m ± (2 μ m+3%) |
|
6000N45S1/6000N45S3 |
Standard/Advanced Type |
N45S (N-type/miniature probe/45 °) | 0~625μm |
At 0~100 μ m ± (0.5 μ m+1%) >At 100 μ m ± (2 μ m+3%) |
|
6000N90S1/6000N90S3 |
Standard/Advanced Type |
N90S (N-type/miniature probe/90 °) | 0~625μm |
At 0~100 μ m ± (0.5 μ m+1%) >At 100 μ m ± (2 μ m+3%) |
|
6000FT1/6000FT3 |
Standard/Advanced Type |
FT (F-type/integrated/medium range probe/) | 0~6mm |
± (0.01mm+1%) at 0-2.5mm >At 2.5mm ± (0.01mm+3%) |
|
6000FTS1/6000FTS3 |
Standard/Advanced Type |
FTS (F-type/medium range probe) | 0~6mm |
± (0.01mm+1%) at 0-2.5mm >At 2.5mm ± (0.01mm+3%) |
|
6000FNTS1/6000FNTS3 |
Standard/Advanced Type |
FNTS (FN dual-purpose/medium range probe) | 0~6mm |
± (0.01mm+1%) at 0-2.5mm >At 2.5mm ± (0.01mm+3%) |
|
6000FTRS1/6000FTRS3 |
Standard/Advanced Type |
FTRS (F-type/medium range/right angle probe) | 0~6mm |
± (0.01mm+1%) at 0-2.5mm >At 2.5mm ± (0.01mm+3%) |
|
6000FHXS1/6000FHXS3 |
Standard/Advanced Type |
FHXS (F-type/large range/high temperature resistance of 250 degrees Xtreme) ™ Probe) |
0~10mm | ±(2μm+3%) | |
6000FKS1/6000FKS3 |
Standard/Advanced Type |
FKS (F-type/large range probe) | 0~13mm | ±(0.02mm+3%) | |
6000NKS1/6000NKS3 |
Standard/Advanced Type |
NKS (N-type/Large Range Probe) | |||
6000FJS1/6000FJS3 |
Standard/Advanced Type |
FJS (F-type/ultra large range probe) | 0~25mm | ±(0.2mm+3%) | |
6000FLS1/6000FLS3 |
Standard/Advanced Type |
FLS (F-type/ultra large range probe) | 0~38mm | ±(0.2mm+3%) | |
6000FNGS1/6000FNGS3 |
Standard/Advanced Type |
FNGS (Ultra Large Range Probe/Non Conductive Coating on Iron and Non Iron Metals) |
0~63.5mm | ±(0.2mm+3%) |
|