Instrument Introduction
The YC-305 portable COD ammonia nitrogen total phosphorus analyzer is designed and developed based on relevant national standards. The instrument is compact, beautiful, and easy to carry. The system adopts a guided operation design with a simple and easy to understand interface, allowing operators to use it quickly and accurately. Adopting a 16mm digestion detection integrated optical colorimetric tube simplifies the operation steps, avoids errors caused by repeated liquid removal, and greatly improves accuracy.
Host technical parameters
|
Testing items |
COD |
Ammonia nitrogen |
total phosphorus |
|
Range of measurement |
0-15000mg/L |
0-50mg/L |
0-20 mg/L |
|
limit of detection |
5mg/L |
0.01mg/L |
0.02mg/L |
|
Dissolve the environment |
165℃,20min |
No need to dissolve |
125℃,30min |
|
error range |
Measurement error ≤± 5%, repeatability ≤± 2% |
||
|
Optical stability |
≤± 0.001A/20 minutes (100000 hours without decay) |
||
|
Colorimetric method |
Colorimetric tube (digestion colorimetric integrated tube) |
||
|
data processing |
2000 records, 80 curves (supports custom extension projects) |
||
|
transmission mode |
USB |
||
|
printer |
Thermal printer (optional) |
||
|
Operation interface |
High definition LCD screen, full Chinese display |
||
|
Power supply mode |
DC3.7V |
||
|
power |
2W |
||
|
work environment |
5-45 ℃ ≤ 85% No condensation |
||
|
Host quality |
310mm * 230mm * 150mm host<3.5kg |
||
Technical parameters of digestion instrument
|
Dissolve sample size |
6 pieces |
time display |
Real time date and time display |
|
Operation interface |
Chinese display |
operating mode |
Touch-tone |
|
rated voltage |
12V 10A |
Power supply mode |
Car mounted, portable power bank, DC |
|
Dissolve pore size/depth |
16mm/65mm |
Dissolving capacity |
>12mL |
|
display screen |
TFT high-definition color screen |
timing error |
10min±0.1s |
|
Pre set digestion mode |
COD、 Total phosphorus and total nitrogen |
Dissolution method |
Fully enclosed type |
|
safety protection |
Double protection against overheating |
temperature control |
Intelligent PID temperature control |
|
custom mode |
5, temperature and time can be set arbitrarily |
Project switching |
Quick switch |
|
Reminder method |
buzzer |
Alarm prompt 1 |
Reaching the specified temperature and maintaining a constant temperature |
|
Custom time |
5-999min adjustable |
Alarm prompt 2 |
Dissolve completed and stop heating |
|
Custom Temperature |
90~200 ℃ adjustable |
Dissolve protection |
Insulation board/protective cover |
|
Temp Accuracy |
<±0.5℃ |
Temperature control sensor |
Imported Platinum PT100 |
|
heating rate |
Constant at 165 ℃ for 12 minutes |
Instrument weight |
Dissolver<1.5kg |
|
work environment |
-10-40 ℃, relative humidity<85% |
External dimensions |
185*120*155(mm) |
Instrument characteristics
1. Complies with relevant national authoritative standards, with precise, safe, rapid, and effective measurements.
2. Adopting imported optical cold light source and filtering system, with stable optical performance and a lifespan of 100000 hours.
3. High definition LCD screen with full Chinese display, direct data reading, simple and time-saving operation.
4. Integrated digestion and colorimetric analysis, no need to replace the tube, simple and fast measurement, and no safety hazards.
5. It can save 80 standard curves and 1800 measured values (date, time, parameters, test data).
6. Memory standard working curve, users can also calibrate the curve according to their needs.
7. One click factory reset, which can quickly recover in case of curve loss caused by misoperation.
8. Data storage function and power-off protection function, convenient for querying historical data and preventing data loss.
9. Equipped with a USB interface, the detection data can be transferred to the computer for permanent storage.
10. It has printing function, which can print the measured values immediately or print historical records.
11. Built in user-defined mode, allowing users to set the digestion time and temperature according to the situation.
12. Memory intelligent self adjustment program, no need for users to adjust system parameters, system intelligent adjustment.
13. It has the function of reminding when the specified temperature is reached, stopping heating and reminding when the sample digestion is completed.
14. External safety cover to prevent potential security threats to users in case of accidents.
15. Adopting intelligent PID temperature control technology and dual anti overheating protection system, heating is safe, uniform, and fast.
Used for the digestion of COD, total phosphorus, total nitrogen and other projects.
Standard configuration
|
Serial Number |
name |
quantity |
Serial Number |
name |
quantity |
|
1 |
Portable COD ammonia nitrogen total phosphorus analyzer host |
1 unit |
6 |
Simplified operation flowchart |
1 copy |
|
2 |
16mm colorimetric tube |
10 pieces |
7 |
operation instructions |
1 copy |
|
3 |
COD ammonia nitrogen total phosphorus determination reagent |
1 set |
8 |
Color comparison rack |
1 piece |
|
4 |
Color tube cleaning cloth |
1 piece |
9 |
Certificate of Conformity/Warranty Card |
1 copy |
|
5 |
6-hole intelligent digestion instrument |
1 set |
10 |
Power Cables |
1 item |