Online natural gas calorific value chromatographic analyzerFor onlinegas chromatographOnline calorific value analysis can be conducted on impurity projects in natural gas to monitor changes in component content, providing important reference data for safe operation.
Gas chromatograph uses gas (hydrogen) as the mobile phase (carrier gas). When the sample is carried into the chromatographic column by the carrier gas through the injection system, the components in the sample are separated in the column due to differences in their distribution or adsorption coefficients on the chromatographic column. The separated components are sequentially detected by the detector. The online chromatograph has the characteristics of unmanned operation, high sensitivity, and good stability. The detection signal can be read and displayed directly or transmitted remotely, and all technical indicators can fully meet the relevant provisions of national standards.
Online natural gas calorific value chromatographic analyzerEnvironmental conditions for use:
Power supply voltage: AC220V (± 10%)
Environmental temperature: 5 ℃~35 ℃
Relative humidity: ≤ 85%
Power: 1kw
Injection pressure: < 0.2Mpa.
GC-LTG online natural gas calorific value analyzer product performance description:
Analytical medium: natural gas.
(1) Column box temperature:
Temperature control range: room temperature~500 ℃
Temperature control accuracy: ± 0.1 ℃
(2) Thermal conductivity detector (TCD):
Baseline noise: ≤ 0.05mv
Baseline drift: ≤ 0.2mv/30min
Detection limit: O2 ≥ 8000mv.ml/mg
(3) Instrument dimensions
Volume: 450 × 430 × 175mm
Weight: 20KG
Characteristics of online natural gas calorific value chromatographic analyzer:
1) It can continuously monitor the sample of the gas to be tested.
2) It is a fully automatic analysis instrument that can automatically schedule, sample, analyze, and achieve good separation and analysis results, with reliable data.
3) It can achieve free switching between automatic and manual injection to obtain more reliable data.
4) The instrument is easy to operate, and the injection and sampling time can be set arbitrarily.
5) Measurement object: natural gas.
6) The first party requests that monitoring data can be uploaded through a 4-20mA interface;
7) Can be equipped with cabinets and necessary pre-processing systems;
8) Meet the corresponding national standards and requirements.
Responsible area |
Regional Head |
Contact number |
Liaoning, Shaanxi, Fujian, Yunnan, Xinjiang, Gansu |
Manager Li |
15542386171 |
Hebei, Shandong, Tianjin, Ningxia, Guangdong, Guangxi, Sichuan |
Manager Liu |
15566818130 |
Inner Mongolia, Shanxi, Henan, Hubei, Qinghai, Chongqing |
Manager Wen |
15566818173 |
Heilongjiang, Jilin, Jiangsu, Zhejiang, Anhui |
Manager Han |
15566818122 |