Olympus metallographic microscopeBX61, as a research grade upright metallographic microscope, adopts the internationally leading UIS infinite distance correction optical system to provide perfect images with high contrast, high brightness, high clarity, and high contrast. It has the characteristics of high signal-to-noise ratio (S/N) and high light transmittance, and has multiple lighting modes to choose from (bright dark field electric conversion type lighting fixture and universal lighting fixture that can accommodate up to 6 sets of spectrometers, all of which are equipped with electric aperture stop). The correction range of BX61 for spectra has been extended from UV (ultraviolet) to IR (infrared), showing excellent performance for microscopic observation. Adopting electric control for dimming, focusing, and reflection transmission switching. These advances only meet the various needs in the field of fluorescence digital imaging at present, while laying a solid foundation for future development.

UIS2The vivid image observed by the objective lens
The UIS2 objective lens equipped with BX61 has a rich product lineup of various magnifications, special purpose objectives, etc., which can be selected according to the purpose. In addition, the high quality brought by wavefront aberration control, faithful neutral color display of the sample, etc., the UIS2 objective lens can demonstrate its outstanding performance in both visual observation and digital image observation.

The labor-saving and efficiency brought by electric control
1. Simple actions to achieve complex functions
It is possible to set numerous optical adjustments in detail and accurately during observation. Simplify and functionalize a series of complicated operations, and allocate its control to buttons on the microscope body, manual switches, and computer buttons (requiring the use of image analysis software analySIS FIVE). With just one simple action, observation conditions can be reproduced.

2. Equipped with various electric units
Equipped with high-speed and durable electric objective converters controlled by computers or manual switches, electric center output objective converters, electric bright and dark field illumination tubes, electric reflective illumination tubes, etc., with a wide variety of electric units.

3. Can be equipped with a dynamic autofocus unit
It can be equipped with a reflection specific dynamic autofocus unit corresponding to a 150 × objective lens. The use of multi-point lasers has achieved higher stability and a larger observation range.

UIS2The vivid image observed by the objective lens
The UIS2 objective lens has a rich product lineup of various magnifications, special purpose objectives, etc., which can be selected according to the purpose. In addition, the high quality brought by wavefront aberration control, faithful neutral color display of the sample, etc., the UIS2 objective lens can demonstrate its outstanding performance in both visual observation and digital image observation.

The labor-saving and efficiency brought by electric control
Functionalization of complex operation macros
It is possible to set numerous optical adjustments in detail and accurately during observation. Functionalize a series of complex operation macros and allocate their control to buttons on the microscope body, manual switches, and computer buttons (requiring the use of image analysis software analySIS FIVE). With just one simple action, observation conditions can be reproduced.
Differential interferometry system providing optimal observation for different samples
Olympus' differential interference observation adopts a sliding single prism method that is easy to switch between observations. In order to obtain the optimal resolution and contrast suitable for the sample state, three types of DIC prisms were prepared, including Meclophene D-ICR, high-resolution U-BICH, and high contrast U-BICHC. In addition, each series of the UIS2 objective lens has a unified pupil position, so there is no need to switch the position of the DIC prism in low magnification to high magnification observations.

Analyzer/polarizer linkage, easy loading and unloading of detection skateboard
When switching from bright field observation to differential interference observation methods, the detection slide of the analyzer/polarizer can be loaded and unloaded at once to quickly complete the switching of observation methods. In addition, the detection slide of the analyzer/polarizer can be installed and removed on either side of the reflector tube.

Different models of stages correspond to multiple samples
In addition to the U-MSSP4 stage with a size of 100 × 100 mm and the U-WHP2 stage that can accommodate the 4-inch x round loader BH2-WHR43, there are also models such as the transmission observation glass flat U-MSSPG stage that can be used as a shielding loader.
Lighting systems corresponding to various light sources
APO model x has been launched on mercury and xenon light sources to correct color difference from visible light to near-infrared. Please select the desired product according to the purpose of use.
Rich attachments meet inspection requirements
In addition to the U-MSSP4 stage with a size of 100 × 100 mm and the U-WHP2 stage capable of carrying 4-inch wafer loaders BH2-WHR43, there are also models such as the transmission observation glass flat U-MSSPG stage that can be used as a shielding loader.
Olympus metallographic microscope BX61Type technical parameters
|
Olympus metallographic microscope BX61 specification |
|||
|
optical system |
UIS2 optical system (infinite correction) |
||
|
fuselage |
Observation method |
Bright field/dark field/differential interference/simple polarized light/fluorescence |
|
|
Reflection/Transmission |
Reflection/Transmission |
||
|
Lighting device |
Electric light dark field reflection lighting device (bright field/dark field/differential interference/simple polarized light) |
||
|
lighting |
Reflective lighting |
100 W halogen/100 W mercury/75 W xenon |
|
|
Transmissive illumination |
100 W halogen |
||
|
Focusing unit |
Electric/manual |
Electric |
|
|
trip |
35 mm |
||
|
Resolution/Fine tuning sensitivity |
Resolution 0.01 μ m |
||
|
Maximum sample height |
25 mm |
||
|
Objective lens converter |
Electric type |
Clear field differential interference with 6 holes |
|
|
Manual type |
- |
||
|
load matter platform |
trip |
Lower right (lower left) handle: 76 (X) × 52 (Y) mm |
|
|
view Inspection tube |
Wide angle field of view (22 fields of view) |
inversion |
Binocular/trinocular/tilted binocular observation tube |
|
Just like |
Three eye/tilted binocular observation tube |
||
|
Ultra wide field of view (26.5 fields of view) |
inversion |
Three eyed observation tube |
|
|
Just like |
Three eye/tilted three eye observation tube |
||
|
Attachment Unit |
Automatic focusing |
||
|
External dimensions |
317.5 (W) × 602 (D) × 541 (H) mm (standard combination) |
||
|
weight |
25.5 kg (standard combination) |
||