Oil Gas Chromatography Analyzer for Power TransformersApplied to oil filled electrical equipmentAnalysis of gases dissolved in insulating oil, including transformers, reactors, current transformers, oil filled bushings, gas relays, etc.
Oil Gas Chromatography Analyzer for Power TransformersPerformance Characteristics
Oil Gas Chromatography Analyzer for Power TransformersIt can predict potential faults of oil filling equipment in advance, ensure its safe operation, and fully meet the national standard "Gas Chromatography for Dissolved Gas Components in Insulation Oil"measureThe requirements of "Determination of Gas Content in Insulation Oil by Gas Chromatography", "Guidelines for Analysis and Determination of Dissolved Gases in Transformer Oil" and "Determination of Gas Content in Insulation Oil by Gas Chromatography".
Oil Gas Chromatography Analyzer for Power Transformersequipped withTCD, FID, and high-efficiency converters improve the detection sensitivity of each component.
One injection can analyze simultaneouslyNine components: H2, O2, N2, CO, CO2, CH4, C2H4, C2H6, C2H2.
aOil chromatography analyzerIt can be used for both analysis of characteristic gases and detection of gas content.
The chromatographic workstation can automatically diagnose faults in the analysis results.
1. Adopting 4.3-inch touchscreen LCD Chinese display, real-time display of various temperatures and operating conditions
2. Power on self-test, five independent temperature control channels;
3. If any sensor circuit breaks, the instrument will automatically display an alarm;
4. High precision dual stable gas path, capable of installing up to four detectors simultaneously;
5. The four-way external event function supports multi valve switching;
6. Optional electronic flow pressure display system and built-in workstation device.
Oil Gas Chromatography Analyzer for Power TransformersTechnical indicators
Hydrogen flame ionization detector(FID):
1. Temperature control range: Room temperature+5 ℃~300 ℃
2. Detection limit: 0.05ppm
3. Linear range: 107
Thermal conductivity detector(TCD):
1. Temperature control range: Room temperature+5 ℃~300 ℃
2. Sensitivity: 8000mv.ml/mg
3. Linear range: 104
4. Bridge current range: 0-200mA, with load gas cut-off protection
Oil Gas Chromatography Analyzer for Power TransformersofSpecifications:
1. Dimensions: 580 x 550 x 500 (mm)
2. Input power supply: AC220V ± 10% 50Hz 2KW
3. Overall weight: approximately 35kg
Oil chromatography analyzerSpecific component detection limit (ul/l) | |||||||||
component |
H2 |
O2 |
N2 |
CO |
CO2 |
CH4 |
C2H6 |
C2H4 |
C2H2 |
Direct detection |
≤2 |
≤50 |
≤50 |
≤0.1 |
≤0.1 |
≤0.1 |
≤0.1 |
≤0.1 |
≤0.1 |
Welcome to call for consultation: Zhu Jintong 15566669567