Coliynuclear radiationClassification List | |||||
Detectable radiation |
PRODUCT MODEL |
sensor |
range |
γX-ray sensitivity(Cs137,1µSv/h) |
characteristic |
portable | |||||
α、β |
R900 |
ZINC SULFIDE+plastic scintillator |
1Mcps |
-- |
Effective area1702 |
R700 |
ZINC SULFIDE+plastic scintillator |
1Mcps |
-- |
Effective area750px2 |
|
α、β、γ |
R500 |
Geiger counter |
1mSv/h |
7cps |
Large end window cover leather pipe Unable to distinguish the type of radiation |
910 |
Geiger counter |
1mSv/h |
2cps |
Small end window cover leather tube Unable to distinguish the type of radiation |
|
R800 |
CZTsemiconductor |
γ:10mSv/h β:1mSv/h |
7cps |
Simultaneously measuring andDistinguish displayα、βandγray |
|
γ |
RS10 Energy spectrum analyzer |
Φ50x50mmsodium iodide |
1mSv/h |
800cps |
Spectral analysis, energy resolution<> |
10x10x10mm3cadmium zinc telluride |
10mSv/h |
60cps |
Spectral analysis, energy resolution<> |
||
R100 |
GMcounter tube (After energy compensation) |
100mSv/h |
2cps |
persondoseAlarm device, energy range20keV~3MeV |
|
R750 |
Φ80x80mm plastic scintillator |
0.2mSv/h |
2000cps |
Environmental grade, ultra-high sensitivity Energy Range15keV~7MeV(±15%) |
|
RW10 |
φ35×35mmsodium iodide |
1.5mSv/h |
400cps |
100Continuous underwater work |
|
ION-H |
Radiation resistant scintillation sensor |
100Sv/h |
77cps |
High range measurement, optional range10Sv/h、 20Sv/h、50Sv/h、100Sv/h |
|
R700 |
Φ75x75mmplastic scintillator |
0.2mSv/h |
1500cps |
Environmental grade, high sensitivity |
|
R700 |
Φ30x30mmsodium iodide |
1mSv/h |
350cps |
answerγHigh radiation detection efficiency、1Quick response in seconds |
|
|
RC510 γX-ray imaging |
GAGGcrystal |
10mSv/h |
500cps |
High sensitivity sensor, encoding hole imaging technology Quickly identify and locate radiation sources |
|
Neutronsγ |
R60N |
10×10×10(mm3)Koley PatentHType sensor |
10mSv/h(Neutron) |
0.5cps(Cf-252 ) |
A single sensor can simultaneously detect neutrons andγray γPSRR≥1000:1 High sensitivity under the same volume3Hesensor20times |
20×20×20(mm3)Koley PatentHType sensor |
2.7cps(Cf-252 ) |
||||
Wall mountedR2000 | |||||
|
γ
|
GM30A |
Geiger counter |
1mSv/h |
2cps |
Small end window cover leather tube X、γEnergy response:50keV-3MeV |
CS30A |
Φ30x30mm plastic scintillator |
1mSv/h |
350cps |
1Quick response in seconds |
|
CS75 |
Φ75x75mmplastic scintillator |
0.2mSv/h |
1500cps |
Environmental grade High sensitivity |
|
Neutronsγ |
N10 |
10×10×10(mm3)Koley PatentHType sensor |
10mSv/h(neutron) |
0.5cps(Cf-252 ) |
A single sensor can simultaneously detect neutrons andγray γPSRR≥1000:1 High sensitivity under the same volume3Hesensor20times |
N20 |
20×20×20(mm3)Koley PatentHType sensor |
2.7cps(Cf-252 )
|
|||
Nuclear radiationShooting Online Monitoring Systeminterconnected systemR2000
sketch
Nuclear Radiation Online Monitoring SystemR2000Integrate the latest updates from KoleyThe developed industrial instrument graphical interface operating system simplifies the operation process of traditional industrial instruments and adopts7Inch color touch screen, combined with sound and light alarm,Enable usersControl the radiation situation in the environment at the first time,To the maximum extent possibleReduce the harm of radiation to the human body.R2000By using different probes, it is possible to detectα、β、Χ、γAnd neutronsRadiation and energy spectrum analysis function. Multiple range and types of probes are available, suitable for radiation monitoring in various scenarios.
Nuclear Radiation Online Monitoring SystemR2000Can be connected simultaneously1-3A probe(maximumScalable to8(individual), can be separated separatelysuperviseMeasuring the radiation intensity values at different locations and displaying them on the screen simultaneously, the application of multiple probes greatly reduces the user's usage costEnable users to obtain more detailed nuclear radiation information.The large display screen can simultaneously display multiple measurement data:Cumulative dose value, real-timedose rateValue, maximum value, minimum value, alarm value, etc.R2000Also hasLarge capacity data storage and data reading function,By connecting to the upper computer software,Users canPCendapproveImplement data storage and analysisBrings great convenience to daily management,probeThe longest cable can reach500Rice.The product has passed through EuropeCECertification andISO9001Quality certification.
application
Nuclear Radiation Online Monitoring SystemR2000It is mainly used to monitor radioactive sites with radiation sources. Staff can determine the leakage status of radiation sources or radiation devices by measuring the radiation dose rate value, and take relevant measures in a timely manner to avoid harm to the human body from radiation. It can be appliedexist:
Environmental monitoring, hygiene and epidemic preventionradiation therapy、Radiology diagnosis and treatment,isotope application、γRadiation, non-destructive testing, import and export inspection, building materials, petrochemical industry, geological survey, codePlaces with radioactive substances such as ports, scrap steel, nuclear laboratories, etcradiation monitoring.
Product characteristics
7Inch color touch screen
GUI operating system, easy to operate
Multiple display modes, clear and concise monitoring data
Multiple probe options available, coveringα、β、X、γAnd neutron detection
Can connect to onebeltγSpectral analysis functionThe probe
Sound and light alarm, reminding users to take relevant measures in a timely manner
Can be connected simultaneously1-3A probe(maximumScalable to8A probe)
Capable of storing large capacity data, realizing the functions of data transmission, storage, and analysis
display mode
Single probe display interface
Using a graphical interface as a system,7The inch color touch screen can display multiple measurement data simultaneously: timeAccumulated valueMaximum value, minimum value, etc.
twoProbe display interface
The screen displays the real-time values of each probe separately.
single clickDisplay resultsYou can directly view the detailed measurement results and set parameters of each probe
Probe configuration
|
|
|
CS30Atypeprobe measureX、γray
|
CS75Type probe Measuring environmental levelX、γray |
|
|
|
N10/N20 probe
|
GM30A probe Measurable X and gamma rays |
Host technical parameters
range |
Refer to the technical parameters of the probe |
Types of sensors |
Refer to the technical parameters of the probe |
Display units |
μSv,μSv/h,μGy/h,cps,cpm,Bq/cm2 |
Host operating temperature |
-10ºCto+70ºC |
Host storage temperature |
-20ºCto+80ºC |
Alarm method |
Optional external alarm light, sound and light alarm |
operating system |
Graphical interface operating system |
Display |
7Inch color touch screen |
Alarm conditions |
Over threshold alarm, instrument malfunction alarm, over range alarm |
Alarm method |
Sound and light alarm, custom alarm threshold |
power supply |
AC 220V |
Relay output type |
1An active output |
digitcommunicationsignal |
RS485 |
weight |
3kg |
Certificate |
European CE,ISO9001 |
Probe parameters
Probe model |
describe |
|
CS30A Sodium iodide scintillation probe |
Measure the type of radiation:Χandγray Detector:φ30×30mmSodium iodidecrystal Range:0.01µSv/h-1000µSv/h Sensitivity:1µSv/h≥350cps(Cs-137) Energy response:50keV-3MeV Relative fundamental error:≤±15% |
|
CS75 Environmental grade plastic scintillator probe
|
Measurement of radiation type: environmental gradeX、γray Detector:φ75×75mmplastic scintillator Range:0.001µSv/h-200μSv/h Sensitivity:1µSv/h ≥1500cps(Cs-137) Energy response:15keV-7MeV Relative fundamental error:≤±10% |
|
N10 HType neutron gamma probe |
Measurement of radiation types: neutronsγray Detector:Koley PatentHtype4πOmnidirectional probe Detecting crystal size:10×10×10(mm3) Range:Neutron:0.1μSv/h-10mSv/h γ:0.01μSv/h-20mSv/h Sensitivity: Neutron:1µSv/h ≥0.5cps(Cf-252) energyin response to:Neutron:0.0025eV-16MeVγ:50keV-3MeV γInhibition ratio:1000:1(Cs-137) Relative fundamental error:≤±15%; Neutron(252Cf )、γ(Cs-137) |
|
N20 HType neutron gamma probe |
Measurement of radiation types: neutronsγray Detector:Koley PatentHtype4πOmnidirectional probe Detecting crystal size:20×20×20(mm3) Range:Neutron:0.1μSv/h-10mSv/h γ:0.01μSv/h-10mSv/h Sensitivity: Neutron:1µSv/h ≥2.7cps(252Cf) energyin response to:Neutron:0.0025eV-16MeVγ:50keV-3MeV γInhibition ratio:1000:1(Cs-137) Relative fundamental error:≤±15%; Neutron(Cf-252)、γ(Cs-137) |
|
GM30A GMcountTube probe |
Measure the type of radiation:Χandγray Detector:Small end window cover leather tube Range:0. 01µSv/h-1000µSv/h Sensitivity:1µSv/h ≥2cps(137Cs) X、γEnergy response:50keV-3MeV Relative fundamental error:≤±15% |
Select accessories
|
External sound and light alarm
The volume can reach up to85dBthe above Adopting ultra-high brightnessLEDlight source High service life50000More than hours |
|