NHR-5200 series dual loop digital display controller
Overview: The NHR5200 series dual circuit digital display controller is designed to collect, display, control, remotely transmit, communicate, and pri
Product details
overview
The NHR5200 series dual circuit digital display controller is designed to collect, display, control, remotely transmit, communicate, and print various signals such as temperature, pressure, liquid level, and speed on site, forming a digital acquisition system and control system. It is widely used in many fields such as power, petrochemicals, metallurgy, light industry, pharmaceuticals, and aviation.
instrument panel
160 * 80mm (Type A) 80 * 160mm (Type B) 96 * 96mm (Type C) 96 * 48mm (D-type) 48 * 96mm (E-type)
160 * 80mm (K-type) 80 * 160mm (L-shaped) 72 * 72mm (F-type)
Parameter function
Note: The above parameters are all parameters of the instrument. If it is not a fully functional instrument, the parameters corresponding to the unselected function will not be displayed.
Instrument wiring diagram
The specifications and dimensions are A, B, C, D, E, K, and L-shaped wiring diagrams
Note: The direction of the wiring terminals on the back cover of the horizontal and vertical instruments is different, as shown in schematic diagram 1.

Figure 1

The specification size is F-type wiring diagram
Note: In the above wiring diagram, if different functions are marked on the same group of terminals, only one function can be selected. If RS485 and RS232 are connected to the same set of terminals, only one can be selected.
instrument selection
NHR-5200□-□/□-□/□/□/□/□( )-□-( )
① ② ③ ④ ⑤ ⑥ ⑦ ⑧ ⑨ ⑩
① Specification and size
code Width * Height * Depth code Dividing number (measurement range)
A
B
C
D
E
F
K
L
160 * 80 * 110mm (horizontal)
80 * 160 * 110mm (vertical)
96 * 96 * 110mm (Method)
96 * 48 * 110mm (horizontal)
48 * 96 * 110mm (vertical)
72 * 72 * 110mm (Method)
160 * 80 * 110mm (horizontal/beam)
80 * 160 * 110mm (vertical/light column)
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
55
56
Thermocouple B (400-1800 ℃)
Thermocouple S (0-1600 ℃)
Thermocouple K (0-1300 ℃)
Thermocouple E division (0-1000 ℃)
Thermocouple T division (-200.0-400.0 ℃)
Thermocouple J division (0-1200 ℃)
Thermocouple R scale (0-1600 ℃)
Thermocouple N division (0-1300 ℃)
Thermocouple F2 division (700-2000 ℃)
Thermocouple Wre3-25 division (0-2300 ℃)
Thermocouple Wre5-26 division (0-2300 ℃)
Thermal resistance CU50 (-50.0-150.0 ℃)
Thermal resistance CU53 (-50.0-150.0 ℃)
Thermal resistance CU100 (-50.0-150.0 ℃)
Thermal resistance PT100 (-200.0~650.0 ℃)
Thermal resistance BA1 (-200.0.0~600.0 ℃)
Thermal resistance BA2 (-200.0-600.0 ℃)
Linear resistance 0-400 Ω (-1999~9999)
Remote transmission resistance 0-350 Ω (-1999~9999)
Remote transmission resistor 30-350 Ω (-1999~9999)
0~20mV (-1999~9999)
0~40mV (-1999~9999)
0~100mV (-1999~9999)
-20~20mV (-1999~9999)
-100~100mV (-1999~9999)
0~20mA (-1999~9999)
0~10mA (-1999~9999)
4~20mA (-1999~9999)
0~5V (-1999~9999)
1~5V (-1999~9999)
-5~5V (-1999~9999)
0-10V (-1999~9999) (non switchable)
0-10mA square root (-1999~9999)
4-20mA square root (-1999~9999)
0-5V square root (-1999~9999)
1-5V square root (-1999~9999)
Full switch
Special specifications
code Output type (load resistance RL)
X
0
1
2
3
4
5
8
no-output
4-20mA(RL≤600Ω)
1-5V(RL≥250KΩ)
0-10mA(RL≤1.2KΩ)
0-5V(RL≥250KΩ)
0-20mA(RL≤600Ω)
0-10V(RL≥4KΩ)
Special specifications
code Output type (load resistance RL)
X
0
1
2
3
4
5
8
no-output
4-20mA(RL≤600Ω)
1-5V(RL≥250KΩ)
0-10mA(RL≤1.2KΩ)
0-5V(RL≥250KΩ)
0-20mA(RL≤600Ω)
0-10V(RL≥4KΩ)
Special specifications
⑥ Number of alarm points (relay contact output)
code Alarm limit
X
1
2
3
4
no-output
1-limit alarm
2-limit alarm
3-limit alarm
4-limit alarm
⑦ Communication output
code Communication interface (communication protocol)
X
D1
D2
D3
no-output
RS-485 communication interface (Modbus)
RS232 communication interface (Modbus)
RS232C printing interface
⑨ Power supply
code Voltage range
A
D
AC/DC 100-240V(50/60Hz)
DC 20-29V
⑧ Feed output ⑩ Remarks
code Feed output (output voltage) code Additional features (none to be omitted)
X
1P
2P
no-output
1-channel feeding output
2-channel feeding output
Q Addition, subtraction, multiplication, and division functions
remarks:
1. When selecting, please refer to the wiring diagram to choose the function. Due to the small size of instrument wiring terminals, they may not have full functionality, and some functions can only be selected from one of them on the same group of terminals.
2. The instrument with a specification size of F-type does not come with an RS232C printing interface
3. For instruments with specifications of D and E types, if there is an alarm function between the wiring terminals 25-36, the relay contact capacity is AC125V/0.5A
DC24V/0.5A, The contact capacity of instrument relays of other specifications and sizes is AC220V/2A, DC24V/2A.
4. When writing the model, it must be complete, and any function items that have not been selected cannot be omitted and must be supplemented with an "X".
Example 1: NHR-5200A-55/55-0/0/4/X/2P (24/24) - A
Example 2: NHR-5200C-27-0/X/X/D1/X-A-Q (addition operation).