NHR-5200 series dual loop digital display controller
Overview: The NHR5200 series dual circuit digital display controller is designed to collect, display, control, remotely transmit, communicate, and pri
Product details
| overview | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
| The NHR5200 series dual circuit digital display controller is designed to collect, display, control, remotely transmit, communicate, and print various signals such as temperature, pressure, liquid level, and speed on site, forming a digital acquisition system and control system. It is widely used in many fields such as power, petrochemicals, metallurgy, light industry, pharmaceuticals, and aviation. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||
instrument panel
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
Parameter function
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() ![]() ![]()
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Note: The above parameters are all parameters of the instrument. If it is not a fully functional instrument, the parameters corresponding to the unselected function will not be displayed. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Instrument wiring diagram
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() The specification size is F-type wiring diagram |
||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Note: In the above wiring diagram, if different functions are marked on the same group of terminals, only one function can be selected. If RS485 and RS232 are connected to the same set of terminals, only one can be selected. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
instrument selection
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
NHR-5200□-□/□-□/□/□/□/□( )-□-( ) ① ② ③ ④ ⑤ ⑥ ⑦ ⑧ ⑨ ⑩ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
| remarks: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 1. When selecting, please refer to the wiring diagram to choose the function. Due to the small size of instrument wiring terminals, they may not have full functionality, and some functions can only be selected from one of them on the same group of terminals. 2. The instrument with a specification size of F-type does not come with an RS232C printing interface 3. For instruments with specifications of D and E types, if there is an alarm function between the wiring terminals 25-36, the relay contact capacity is AC125V/0.5A DC24V/0.5A, The contact capacity of instrument relays of other specifications and sizes is AC220V/2A, DC24V/2A. 4. When writing the model, it must be complete, and any function items that have not been selected cannot be omitted and must be supplemented with an "X". Example 1: NHR-5200A-55/55-0/0/4/X/2P (24/24) - A Example 2: NHR-5200C-27-0/X/X/D1/X-A-Q (addition operation). |
||||||||||||||||||||||||||||||||||||||||||||||||||||||