Multy8340 Multi Parameter Water Quality Analyzer (PONSEL, France)Product Introduction

1Model and specifications of the equipment
model:single channelODEON Multy 8310
dual-channelODEON Multy 8320
dual-channelODEON Multy 8330
dual-channelODEON Multy 8340
manufacturerFrance PONSEL
country of origin:France
Multy8340 Multi Parameter Water Quality Analyzer (PONSEL, France)Electrode parameters
| model | Single parameter | multi-parameter | |||||
| pH/ORP/T | dissolved oxygen | conductivity |
turbidity/Suspended solids |
single channel | dual-channel | ||
| electrode |
PH electrode | X | X | X | |||
| dissolved oxygen electrode | X | X | X | ||||
| Conductivity electrode | X | X | X | ||||
| Turbidity electrode | X | X | X | ||||
| Multi parameter probe | X | X | |||||
| Photometer probe | X | X | |||||
| number of channels | 1 | 2 | |||||
| digital technology | Single parameter can be upgraded to multi parameter | Single/dual channel multi parameter | |||||
| memory | 100 thousandGroup data (including sample ID, user ID, time and date) .) | ||||||
| data management | comply withGLPstandard | ||||||
| ID | Sample, project, user: Character table, * 10 more words, 20 users | ||||||
| reading/record | 3 modes: manual, interval, continuous | ||||||
| Electrode status indication | yes | ||||||
| Automatic diagnostic function | yes | ||||||
| display screen | LCD 4’Inch backlit display screen, 240 x 320.Automatic switching of economic mode. displayTime and date, user, sample, ° C, status, pressure Simultaneously display 1 to 7 measurement parameters (* multiple) | ||||||
| power supply | 4 AA rechargeable batteries (charger required) | ||||||
| runtime | 2000 hours of standard battery (in economy mode) | ||||||
| interface |
-USB -RS 485 interface (1 or 2 electrodes) -External 12V or charger |
||||||
| shell | PC/ABS | ||||||
| Size - Weight | 196 x 121x 46 mm - 400 g | ||||||
| Protection level | Outdoor design, IP67, waterproof | ||||||
| Operating Temperature | - 10to+ 60°C | ||||||
| Storage temperature | - 25to+ 65°C | ||||||
| Operating Humidity | > 80% | ||||||
By purchasing a PHOTOPOD photometer probe, you can upgrade to a multifunctional water quality analyzer that can test COD, ammonia nitrogen, total phosphorus, total nitrogen, phosphate, sulfate ions, nitrate, nitrite, residual chlorine, hexavalent chromium 、 More than 50 parameters including Al, Cu, Fe, Mn, Mo, Zn, etc.
3、 Digital electrode capable of accepting single parameters
1. Plug and play digital electrodes: measurement anytime, anywhere
2. More reliable readings: self detection, automatic diagnosis of status and calibration
3. Durable and sturdy: Designed for outdoor use, suitable for laboratories, wastewater treatment, natural water bodies, and aquaculture
4. Flexible and intelligent sensors: calibration and historical data storage
5. Ultra low energy consumption design: long-term field practice
6. PONSEL sensor: 50 years of sensor manufacturing experience
| electrode | pH/ORP T | dissolved oxygen/ T | conductance/ T | turbidity/ T | |
| application | Laboratory and field | Laboratory and field | Laboratory and field | Laboratory and field | |
| compatibility |
Drinking water, sewage treatment, seawater, rivers, Natural water bodies . |
Drinking water, sewage treatment, seawater, rivers, natural water bodies . | Drinking water, sewage treatment, seawater, rivers, natural water bodies . | Drinking water, sewage treatment, seawater, rivers, natural water bodies . | |
| sensor | pH, ORP, temperature | OPTOD, Temperature | Conductivity, salinity, temperature | Turbidity, temperature | |
| Size (D x L) | 23 x 159 mm | 25 x 146 mm | 27 x 177 mm | 27 x 170 mm | |
| Standard cable length | 3 m | 3 m | 3 m | 3 m | |
| Weight (3m cable) | 350 g | 450 g | 350g | 300 g | |
| protection level | IP68 | IP68 | IP68 | IP68 | |
| operationtemperature | -10°C – 50°C | -10°C – 50°C | -10°C – 50°C | -10°C – 50°C | |
| temperaturesensor | CTN | CTN | CTN | CTN | |
| communication interface | Modbus RS 485 | Modbus RS 485 | Modbus RS 485 | Modbus RS 485 | |
| material | PVC | Inox 316 L | PVC | PVC PMMA | |
| Replacement parts | pH/ORP Cartridge | DODisc® | - | - | |
| Shelf life of electronic devices | 2 years | 2 years | 2 years | 2 years | |
| parameter | pH | ORP | dissolved oxygen | Conductivity, salinity | turbidity |
| measurement range | 0,00 – 14,00 pH |
-1000,0 mV +1000,0 mV |
0,00 – 20,00 mg/L 0 – 200% SAT |
4Range of measurement 0-200,0 µS/cm 0-2000 µS/cm 0,00-20,00 mS/cm 0,0-200,0 mS/cm |
0 - 4000 NTU 4Range of measurement: 0,0 – 50,0 NTU 0,0 – 200,0 NTU 0 – 1000 NTU 0 – 4000 NTU |
| Range selection | - | - | - | automatic/manual | Automatic |
| resolution | 0,01 pH | 0,1 mV |
0,01 mg/L 1%SAT |
0,01to1 µ/mS/cm | 0,1to1 NTU-mg/L |
| precision | ±0,1 pH | ±1 mV |
± 0,1 mg/L ±0,1 % |
±1 %(Full scale) | ±1 %(Full scale) |
| compensation | temperature | - |
Air pressure, temperature, salinity (Mode: Off, Manual, Auto) |
temperature | temperature |
| Measuring principle |
PONSEL 'PLASTOGEL'® Gel electrolyte Ag/AgCl reference electrode |
Platinum electrode Ag/AgCl reference electrode |
PONSEL OPTOD® fluorescence method ASTM D888-05 standard |
4-electrode conductivity technology (2 platinum electrodes and 2 graphite electrodes) |
90°infrared technology ISO 7027standard |
|
response timet90 entire process: 0 – 99% |
< 5 s | < 5 s | < 1 s | < 5 s | < 5 s |
4、 Digital electrode capable of connecting multiple parameters
1. The same electrode can measure 9 parameters
2. Using optical technology to measure dissolved oxygen
3. Adopting the numerical control communication system Modbus RS-485 and SDI12
4Sturdy and tightly structured
5Measurement parameters: temperature pH/ORP、Conductivity/salinity/total dissolved solids, dissolved oxygen (saturation%, ppm, mg/L), turbidity (NTU, FNU), suspended solids (mg/L).
| parameter | range | precision | sensor type | |
| PH/REDOX/T°C | temperature | 0,00to+ 50,00 °C | ±0,1°C | stainless steelCTN |
| pH | 0,00to14,00 pH | ±0,1 |
PONSELplasticization 'PLASTOGEL'®.electrode Ag/AgClreference electrode |
|
| ORP | - 1000,0to+ 1000,0 mV | ±2 mV |
Platinum wire electrode Ag/AgCl reference electrode |
|
| OPTODâ | dissolved oxygen/T°C |
0,00to20,00 mg/L 0,0to200,0 % SAT |
±0,1 mg/L ±1 % |
PONSEL OPTOD Optical technology comply withASTM D888 – 05standard |
| C4E | conductivity |
0,0to200,0 ; 0to2 000 µS/cm 0,00to20,00. 0,0to200,0 mS/cm |
Full range±1 % |
C4E technology with 4 electrodes (2 platinum wire electrodes and 2 graphite electrodes) |
| salinity | 0,00-150,00 ppt | Full range±0,5 % |
C4E technology with 4 electrodes (2 platinum wire electrodes and 2 graphite electrodes) |
|
| NTU | turbidity |
0,00to50,0 ; 0,0to200,0 NTU 0 to1000 NTU ; 0to4000 NTU Automatic range switching range0-4500 mg/L |
Full range±1 % | IR 90°Technology, compliantISO 7027standard |
5、 Digital photometer probe that can be connected
| PHOTOOD Technical Parameters | |
| Device Type | LED technology water quality analysis micro treatment photometer |
| wavelength | 639 nm,591 nm,518 nm,468 nm,400 nm |
| Light source | Silicon photocell |
| Coloring dish slot | Round, diameter 16mm |
| cantest project | COD, NH4+-N,PO43- , NO3-, NO2-,Ptotal, Ntotal, Cl-,F-, CN-,BZT ,ClO2, SiO2, Cr6+, Cr,MO4-,Mo, pH,Al, Br2, Cu,Ni,Zn,Residual chlorine, total chlorine,Cyanuric acidMore than 50 parameters including hydrazine, hardness, and total alkalinity |
| Wavelength adjustment | automatic |
| Blank measurement | Electronic Memory |
| Measurement Mode | Directly expressed as concentration,absorbanceOr transmittance |
| signal interface | Digital RS-485 |
| connector | ODEON Computer connection with transmission software |
| size | *Large height: 62 mm; Length x Width: 96x58 mm |
| Intermediate contact material | ABS |
| Protection level | IP67 |