VIP member
Multi functional salt spray corrosion test chamber
Product use: The composite salt spray corrosion test chamber is suitable for components or equipment that are designed to withstand salt containing at
Product details
| Device Model | Studio size (D * W * H) mm | Dimensions (D * W * H) mm | |
| LRHS-108-RFHY | 450×600×400 | According to the three views of the contract | |
| LRHS-270-RFHY | 600×900×500 | ||
| LRHS-412-RFHY | 750×1100×500 | ||
| LRHS-663-RFHY | 850×1300×600 | ||
| LRHS-816-RFHY | 850×1600×600 | ||
| LRHS-1080-RFHY | 900×2000×600 | ||
|---|---|---|---|
Technical Specifications
Sales Hotline: 021-608 99999
| sex can point mark |
temperature range | -30℃~80℃ |
| humidity range | 30%~98% RH | |
| Saturation bucket temperature | RT+10℃~70℃ | |
| Temperature Uniformity | ≤2℃ | |
| temperature fluctuation | ±0.5℃ | |
| Salt spray deposition amount | 1-2ml/80 cm ². h (16 hour average) | |
| heating rate | 0.5℃~1.5℃/min | |
| 降温速率 | 0.5℃~1.0℃/min | |
| Compressed air pressure | 2.00±0.01(kg/cm²) | |
|---|---|---|
| spray mode | Continuous/Periodic Optional | |
| Sample holder angle | Can meet 15 ° and 30 ° tilt tests | |
| Test Method | NSS test AASS test CASS test | |
| make use material material |
Box material | PP reinforced hard plastic board or 316 stainless steel |
| Box cover material | PP reinforced hard plastic board or 316 stainless steel | |
| Air saturated bucket | Imported high-grade stainless steel SUS304 | |
| Compressed air pipe material | High quality rubber tubing | |
| Other pipelines | Thickened fluorosilicone rubber tube | |
| nucleus heart match place |
Temperature Controller | Imported "Youyi Control" brand temperature and humidity instruments |
| Dehumidification and cooling | Single machine or double machine cascade refrigeration | |
| compressor | Taikang, France | |
| temperature sensor | PT100 platinum resistance thermometer | |
| heating tube | Titanium alloy heating tube | |
| circuit breaker | Schneider miniature circuit breaker (prevents control circuit short circuit) | |
| Standard Configuration | V-shaped sample holder, round rod, nozzle, funnel, measuring cylinder, mist tube | |
| safety protection | Overtemperature, under phase/reverse phase of the whole machine, test timing, rapid defogging indication Low water level protection, leakage, short circuit, compressor overpressure overload, end of test |
|
| power supply voltage | AC380V±10% 50Hz | |
| Power | 8.5kW/10.0kW/12.0kW/13.5kW/15.0kW/17.5kW | |
| Usage environment | 5℃~+28℃ ≤85% RH | |
| Note: 1. The test data were measured under good ventilation conditions at an ambient temperature of 25 ℃ 2. The above parameters are for reference only and can be customized according to the specific testing parameters of the user 3. This technical information is subject to change without prior notice |
||
Online inquiry