Model 2022B Ozone Analyzer from the United StatesThe 2B ozone technology in China is designed based on mature 254nm ultraviolet absorption technology to measure ozone levels ranging from low ppb (with an accuracy of~1.5ppb) to 250000 ppb (0-250ppm). Flash memory card storage and a quiet, long-lasting internal air pump are now standard on the 202 ozone monitor. The 202 type ozone monitor is lightweight (5.5 pounds, 2.5 kilograms) and has lower power consumption compared to traditional instruments (12V DC, 0.60 amperes, 7.2 watts), making it very suitable for applications such as:
Conduct vertical profile analysis using balloons, kites, RPVs, and light aircraft, where space and weight are very limited
·Long term monitoring in highly restricted remote areas
Urban Ground Detector Array
Personal exposure monitoring of air pollutants and their impact on health
Environmental Health and Monitoring
Laboratory study on the effects of ozone exposure on materials and organisms
Model 2022B Ozone Analyzer from the United StatesThe EUT2B standard has been recognized by EPA as a Federal Equivalent Method (FEM): EQOA0410-190.
Principle of 254 nm UV absorption measurement
The Federal Equivalent Method (FEM) is, EQOA0410-190
Linear dynamic range 0250 ppm
Resolution 0.1 ppb
Readings with accuracy (1 Ω; rms noise) greater than 1.5 ppb or 2%
Reading with a sexual content of up to 1.5 ppb or 2%
Detection limit (2 Ω) 3 ppb (10-S measurement mode)
NIST traceability calibration
Measurement interval of 10 seconds (data averaging options: 1 minute, 5 minutes, 1 hour)
Flow rate (nominal)~1 liter/minute
Traffic requirement>0.6 liters/minute
Baseline drift<2 ppb/day
<5 ppb/year
Sensitivity drift<1%/day
<3%/year
Measurement time, frequency 10 seconds, 0.1 Hz
Response time, step change 100% s 20 s, 2 points
Average time: 1 minute, 5 minutes, 1 hour
The internal data logger has a capacity of 16383 rows (10-S MEAS). =1.9 days; 1 minute AVG=11 days; 5-minute AVG=1.9 Mo;
1H-AVG=1.9 years
SD card recorder capacity is 2 GB smaller (>5 years capacity 10 s measurement mode)
Ozone units PPB, PPM, PPHM, γ G-3, MG-3
pressure unit
Temperature units: ° C, K
T and P corrections are
Working temperature range: 050 ℃ standard; Optional -2050 ℃ low-temperature modification (pump and lamp heater packaged in cold weather)
Operating altitude range -0 to 135km (150 to 1013 millibars) standard; Optional -0~25km (30~1013 millibars) pressure sensor
Power requirements;
Powered by battery or 110/220 VAC power pack, 11-14V DC or 120/240V AC, 600mAh, 7.2W (with 6.2W battery heater unplugged)
Size 3.5 x 8.5 x 11 inches (9 x 21 x 29 centimeters)
Weight 5.5 pounds (2.5 kilograms); 2.8 pounds (1.3 kilograms) without instruments