Product Introduction
traditionalVickers hardness testerDifferent, this visual seriesVickers hardness testerCancel the use of measuring eyepieces, project the Vickers indentation image onto the operation screen, and measure the indentation diagonal on the screen. The testing process is faster and more intelligent to meet your requirements for efficient, convenient, and accurate hardness testing.
Characteristics of "Aolongxin"
High precision step controlled electric loading technology
1. The loading speed of the main test force is extremely fast, resulting in improved efficiency
2. Real time video measurement for better, more accurate, and stable results
3. High precision sensor coordinationAolongxin Control System
4.“Unique force curve chart of "Aolongxin"
5. Add and unloadFaster and more precise loading speed
6.Adopting unique embedded visual technology
7.Simple measurement operation greatly reduces human error
8.Can achieve remote control, easy to operate
9. Extremely fast loading speed: test force loading time2-10 seconds
10.Intelligent control throughout the entire process. Segmented force application, smooth variable speed, high-precision and high-speed step control, etc
Visual system characteristics
●Objectivity: The visual system has objectivity, and the analysis results are not affected by subjectivity
●High grayscale resolution: average for the human eye64 grayscale, machine vision can reach up to 256 grayscale
● Embedded imaging technology replaces traditional measuring eyepieces with cameras+Display screen
●Mode, indentation image, directly displayed on the screen
●Visual chip type: Industrial grade dedicated high-definition camera
●Contrast, brightness, white balance and other adjustments are all available
●The visual analysis mode simplifies the manual operation process, reduces personnel fatigue, and makes measurement data more intuitive and convenient
● Optimize each step, greatly improve overall performance compared to traditional hardness testers, and save time50%
The advantages of visual system over eyepiece measurement
●Directly measure on the surface that needs to be measured without visual error. Traditional hardness testers use eyepieces for measurement, and the scale line and indentation are not on the same plane. Under different viewing angles, there will be visual differences between the scale position and indentation position, resulting in differences in measurement results from different viewing angles and personnel
● High measurement accuracy: There is no problem of mechanical eyepiece backlash. The resolution of the mechanical eyepiece spiral micrometer scale isAbout 10 μ m, and there is mechanical hysteresis, so the measurement method needs to be strictly defined. The pixel spacing of the image sensor in the visual system is 7.5 μ m, with relatively high accuracy and good measurement consistency
●Multiple measurement methods can be provided for simultaneous two-dimensional measurement, simplifying the measurement process and improving measurement speed
●Capable of rectangular tangent measurement method
● No visual fatigue, reducing measurement labor intensity. The Aolong visual system adopts65K true color TFT LCD screen, comfortable to observe without fatigue, and can be measured by multiple people at the same time
Technical Specifications
|
model |
MHVS-5V |
MHVS-10V |
MHVS-30V |
MHVS-50V |
|
Test force (kgf) |
0.2, 0.3, 0.5, 1, 2, 2.5, 3, 5 |
0.3, 0.5, 1, 2, 2.5, 3, 5, 10 |
0.5, 1, 2, 3, 5, 10, 20, 30 |
1. 2, 3, 5, 10, 20, 30, 50 |
|
loading method |
Automatic loading and unloading |
|||
|
Test force switching |
automatic |
|||
|
Language Selection |
Chinese-English translation |
|||
|
Duration Time |
5-60s |
|||
|
Pressure head objective lens switching |
automatic |
|||
|
Testeable parameters |
HV |
|||
|
objective lens |
5 times, 20 times |
|||
|
Maximum measurement length |
400μm |
|||
|
minimum resolution |
0.1μm |
|||
|
Maximum height of sample |
100mm |
|||
|
Distance from the center of the pressure head to the body |
95mm |
|||
|
Hardness conversion |
HVTheHKTheHRATheHRBTheHRCTheHRDTheHRETheHRFTheHRG.TheHRKTheHR15NTheHR30NTheHR45NTheHR15TTheHR30TTheHR45TTheHBW |
|||
|
Touch screen operation panel |
Image, force curve, optionsdataLibrary, control, loading startLight adjustmentObjective lens switching |
|||
|
numbervaluedisplay |
D1、D2 valueTheHV、HK instructions、hardness value、conversion value、Load retention time、Test count |
|||
|
light source |
5V/3WWhite LED |
|||
|
communication interface |
RS 232 |
|||
|
execution standard |
JJG151,GB/T 4340,ISO/DIN6507,ASTM E-384 |
|||
|
Photographic device |
Built in high-definition camera |
|||
|
power supply |
AC90-240,50-60Hz |
|||
|
Overall dimensions(Length, Width, Height) |
520*260*550mm |
|||
|
Net weight of the machine |
About 40kg |
|||
Sample Requirements
Although Vickers hardness can measure both softer and harder materials, it also has its own requirements for the sample. Only by selecting appropriate samples can we avoid the errors caused by this and obtain accurate Vickers hardness values.
Appearance requirements for the sample
The surface of the Vickers hardness test sample should be smooth and flat, without oxide scale or impurities, and without oil stains. Generally, the surface roughness parameter of Vickers hardness test specimensRa is not greater than 0.40 μ m, small load Vickers hardness specimens are not greater than 0.20 μ m, and micro Vickers hardness specimens are not greater than 0.10 μ m. (μ m is the unit of surface roughness parameter Ra.). )
Requirements for sample preparation
During the preparation process of Vickers hardness specimens, the influence of factors such as overheating or cold work hardening on surface hardness should be minimized as much as possible.
In addition, for samples with small cross-sections or irregular shapes, such as spherical or conical shapes, it is necessary to embed the samples or use specialized platforms.
Host standard configuration
|
name |
quantity |
name |
quantity |
|
Cross test bench |
1only |
Thin film clamping table |
1only |
|
Flat mouth clamping table |
1only |
Fine wire clamping table |
1only |
|
screwdriver |
2turn |
Horizontal adjustment screw |
4only |
|
|
|
Microhardness block |
2block |
|
level gauge |
1only |
spare fuses |
2only |
|
Product User Manual |
1copy |
Product Qualification Certificate |
1copy |