Low speed freezing large capacity centrifuge DL-5000CThe performance characteristics are as follows:
The machine adopts an automatic balancing device, which has the advantages of low noise, smooth operation, convenient operation, safety and reliability. It can be widely applied in experiments and scientific research in fields such as biology, chemistry, medicine, pharmacology, etc. This machine can be safely used in environments with temperatures ranging from 5 to 40 ℃, relative humidity not exceeding 80%, and no conductive dust, explosive gases, or corrosive gases in the surrounding area.
Low speed freezing large capacity centrifuge DL-5000CDaily maintenance:
Before operating the centrifuge, the power should be cut off and the centrifuge brake should be released first. You can manually try rotating the drum to see if there is any biting.
Check for looseness and abnormal conditions in other parts.
Turn on the power and drive clockwise to start (usually taking about 40-60 seconds from a stationary state to normal operation).
Usually, each device needs to run empty for about 3 hours after arriving at the factory, and can work without any abnormal conditions.
Materials should be placed as evenly as possible.
Special personnel must be assigned to operate, and the capacity must not exceed the rated amount.
It is strictly prohibited to operate the machine at excessive speed to avoid affecting its service life.
After the machine is started, if there are any abnormal situations, it must be stopped for inspection, and if necessary, it must be disassembled, cleaned, and repaired.
The centrifuge operates at high speed, so do not touch its drum with your body to prevent accidents.
The mesh size of the filter cloth should be determined according to the size of the solid particles of the separated material, otherwise it will affect the separation effect. In addition, the filter cloth should be installed when installing it
The sealing ring is embedded in the sealing groove of the drum to prevent materials from running in.
To ensure the normal operation of the centrifuge, please refuel and maintain the rotating parts every 6 months. At the same time, check the lubrication condition of the bearings and whether there is any wear or tear; Check if there is any wear and tear on the components in the braking device, and replace them if necessary; Check for oil leakage in the bearing cover.
After using the machine, it should be cleaned and kept tidy.
Do not separate non corrosion resistant centrifuges from highly corrosive materials; In addition, strictly follow the equipment requirements and regulations for operation. Non explosion proof centrifuges must not be used in flammable or explosive environments.
Technical parameters:
Zui high-speed Max Speed 5000rpm (revolutions per minute)
The maximum relative centrifugal force is Max RCF 6000(×g)
Angle rotor capacity 1200ml × 6
Timer Range: 0min to 60min
Power Supply 220V 50Hz 3000w
Dimensions 500mm × 620mm × 790mm (L × W × H)
Weight: 206kg
model |
product name |
Zui High Speed |
The maximum relative separation force |
Rotor name |
Specification capacity |
DL-5000C |
Low speed freezing large capacity centrifuge (computer-controlled by variable frequency motor) (made entirely of stainless steel) |
5000 revolutions per minute |
6000(xg) |
|
Single machine |
Horizontal Type 1 (with hood) |
4000 revolutions per minute |
4740(xg) |
horizontal |
1200mlx6 |
|
Horizontal Type 2 (with hood) |
5000 revolutions per minute |
6000(xg) |
500mlx6 |
||
50mlx24 | |||||
10mlx72 | |||||
15mlx42 | |||||
7mlx72 | |||||
5mlx72 |