Low pressure (altitude) test chamber
Product use: Low pressure (altitude) test chamber is mainly used in aviation, aerospace, information, electronics and other fields to determine the en
Product details
| Equipment model | Studio size (D * W * H) mm | Dimensions (D * W * H) mm | |
| LRHS-101B-LF | 450×450×500 | 1500×1120×1930 | |
| LRHS-225B-LF | 500×600×750 | 1550×1270×2160 | |
| LRHS-504B-LF | 700×800×900 | 2000×1470×2290 | |
| LRHS-800B-LF | 800×1000×1000 | 1900×1560×2550 | |
| LRHS-1000B-LF | 1000×1000×1000 | 2100×1560×2550 | |
|---|---|---|---|
| sexually ability finger treetop |
temperature range | A:-20℃~150℃ B:-40℃~150℃ C:-60℃~150℃ D:-70℃~150℃ |
|||||
| temperature uniformity | ≤ 2 ℃ (when unloaded) | ||||||
| temperature fluctuation | ± 0.5 ℃ (when unloaded) | ||||||
| Pressure Range | Normal pressure (100KPa)~1KPa | ||||||
| Pressure deviation | Normal pressure~50Kpa: ± 2Kpa; | ||||||
| heating rate | RT~150 ℃ ≤ 60min (at atmospheric pressure without load) | ||||||
| cooling rate | RT~-40 ℃ ≤ 40min (at atmospheric pressure without load) | ||||||
| Voltage reduction time | ≤ 45 minutes (atmospheric pressure~30KPa) | ||||||
| Time setting range | 1~60000M | ||||||
| Air cooling method | Multi stage membrane air heat exchanger | ||||||
| Pressure regulation method | Dynamic pressure balance method | ||||||
|---|---|---|---|---|---|---|---|
| send use material material |
External material | High quality A3 steel plate electrostatic spraying | |||||
| Inner box material | Imported high-grade stainless steel SUS304, pressure bearing layer reinforced with thickened stainless steel | ||||||
| Insulation material | Rigid polyurethane foam+glass fiber | ||||||
| pit the heart join in marriage place |
temperature controller | Imported "Youyi Control" brand temperature instrument | |||||
| temperature sensor | PT100 platinum resistance thermometer | ||||||
| Cooling method | Single machine or double machine cascade refrigeration | ||||||
| compressor | Taikang, France/Bizelle, Germany | ||||||
| Safety protection | Compressor overpressure overload, fan motor overheating, overall equipment under phase/reverse phase Overtemperature, overall equipment timing, leakage protection, overload and short circuit protection |
||||||
| supply voltage | AC380V±10% 50Hz | ||||||
| Power | (A)12kW/16kW/20kW/24kW/28kW (B)17kW/22kW/27kW/31kW/35kW (C)20kW/25kW/34kW/38kW/42kW |
||||||
| Usage environment | 5℃~+28℃ ≤85% RH | ||||||
| Note: 1. The above data were measured under good ventilation conditions at an ambient temperature of 25 ℃ 2. Customized low-pressure (altitude) test chambers can be customized according to specific testing requirements of users 3. This technical information is subject to change without prior notice |
|||||||